Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison

被引:28
|
作者
Krazinski, Aleksander W. [1 ]
Meinel, Felix G. [1 ,2 ]
Schoepf, U. Joseph [1 ,3 ]
Silverman, Justin R. [1 ]
Canstein, Christian [4 ]
De Cecco, Carlo N. [1 ,5 ]
Geyer, Lucas L. [1 ,2 ]
机构
[1] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[2] Ludwig Maximilians Univ Hosp, Inst Clin Radiol, Munich, Germany
[3] Med Univ S Carolina, Dept Med, Div Cardiol, Charleston, SC 29425 USA
[4] Siemens Healthcare, CT Div, Malvern, PA USA
[5] Univ Rome Sapienza Polo Pontino, Dept Radiol Sci Oncol & Pathol, Latina, Italy
关键词
CT angiography; Cardiac CT; Aorta; Radiation dose; Tube potential; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; DUAL-SOURCE CT; CORONARY-ANGIOGRAPHY; POTENTIAL SELECTION; CURRENT MODULATION; ABDOMINAL-AORTA; PEDIATRIC CT; CHEST CT; KILOVOLTAGE; REDUCTION;
D O I
10.1007/s00330-014-3312-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the effect of automated tube voltage selection on radiation dose and image quality at cardiovascular CT angiography (CTA). We retrospectively analysed paired studies in 72 patients (41 male, 60.5 +/- 16.5 years), who had undergone CTA acquisitions of the heart or aorta both before and after the implementation of an automated x-ray tube voltage selection algorithm (ATVS). All other parameters were kept identical between the two acquisitions. Subjective image quality (IQ) was rated and objective IQ was measured by image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and figure of merit (FOM). Image quality parameters and effective dose were compared between acquisitions. Overall subjective image quality improved with the percentage of cases scored as adequate or higher increasing from 79 % to 92 % after implementation of ATVS (P = 0.03). SNR (14.1 +/- 5.9, 15.7 +/- 6.1, P = 0.009), CNR (11.6 +/- 5.3, 13.2 +/- 5.6, P = 0.011), and FOM (19.9 +/- 23.3, 43.8 +/- 51.1, P < 0.001) were significantly higher after implementation of ATVS. Mean image noise (24.1 +/- 8.4 HU, 22.7 +/- 7.1 HU, P = 0.048) and mean effective dose (10.6 +/- 5.9 mSv, 8.8 +/- 5.0 mSv, P = 0.003) were significantly lower after implementation of ATVS. Automated tube voltage selection can operator-independently optimize cardiovascular CTA image acquisition parameters with improved image quality at reduced dose. aEuro cent Automatic tube voltage selection optimizes tube voltage for each individual patient. aEuro cent In this population, overall radiation dose decreased while image quality improved. aEuro cent This tool may become valuable for improving dose/quality ratio.
引用
收藏
页码:2677 / 2684
页数:8
相关论文
共 50 条
  • [21] Reduced dose CT with model-based iterative reconstruction compared to standard dose CT of the chest, abdomen, and pelvis in oncology patients: intra-individual comparison study on image quality and lesion conspicuity
    Linda Nayeli Morimoto
    Aya Kamaya
    Isabelle Boulay-Coletta
    Dominik Fleischmann
    Lior Molvin
    Lu Tian
    George Fisher
    Jia Wang
    Jürgen K. Willmann
    Abdominal Radiology, 2017, 42 : 2279 - 2288
  • [22] Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT
    Wenz, Holger
    Maros, Mate E.
    Meyer, Mathias
    Gawlitza, Joshua
    Foerster, Alex
    Haubenreisser, Holger
    Kurth, Stefan
    Schoenberg, Stefan O.
    Groden, Christoph
    Henzler, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2016, 3 : 182 - 190
  • [23] Achieving consistent image quality and overall radiation dose reduction for coronary CT angiography with body mass index-dependent tube voltage and tube current selection
    Wang, G.
    Gao, J.
    Zhao, S.
    Sun, X.
    Chen, X.
    Cui, X.
    CLINICAL RADIOLOGY, 2014, 69 (09) : 945 - 951
  • [24] Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol
    Park, Young Jean
    Kim, Young Jin
    Lee, Ji Won
    Kim, Hee Yeong
    Hong, Yoo Jin
    Lee, Hye-Jeong
    Hur, Jin
    Nam, Ji Eun
    Choi, Byoung Wook
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (03) : 184 - 190
  • [25] Evaluation of automated attenuation-based tube potential selection in combination with organ-specific dose reduction for contrast-enhanced chest CT examinations
    Schimmoeller, L.
    Lanzman, R. S.
    Dietrich, S.
    Boos, J.
    Heusch, P.
    Miese, F.
    Antoch, G.
    Kroepil, P.
    CLINICAL RADIOLOGY, 2014, 69 (07) : 721 - 726
  • [26] Effect of Automatic Tube Current Modulation on Radiation Dose and Image Quality for Low Tube Voltage Multidetector Row CT Angiography: Phantom Study
    Schindera, Sebastian T.
    Nelson, Rendon C.
    Yoshizumi, Terry
    Toncheva, Greta
    Nguyen, Giao
    DeLong, David M.
    Szucs-Farkas, Zsolt
    ACADEMIC RADIOLOGY, 2009, 16 (08) : 997 - 1002
  • [27] Comparison of Image Quality and Radiation Dose between Fixed Tube Current and Combined Automatic Tube Current Modulation in Craniocervical CT Angiography
    Lee, E. J.
    Lee, S. K.
    Agid, R.
    Howard, P.
    Bae, J. M.
    terBrugge, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (09) : 1754 - 1759
  • [28] Low tube voltage prospectively ECG-triggered coronary CT angiography: a systematic review of image quality and radiation dose
    Tan, Sock Keow
    Yeong, Chai Hong
    Aman, Raja Rizal Azman Raja
    Ng, Kwan Hoong
    Aziz, Yang Faridah Abdul
    Chee, Kok Han
    Sun, Zhonghua
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1088):
  • [29] Iterative Reconstruction to Preserve Image Quality and Diagnostic Accuracy at Reduced Radiation Dose in Coronary CT Angiography An Intraindividual Comparison
    Yin, Wei-Hua
    Lu, Bin
    Li, Nan
    Han, Lei
    Hou, Zhi-Hui
    Wu, Run-Ze
    Wu, Yong-Jian
    Niu, Hong-Xia
    Jiang, Shi-Liang
    Krazinski, Aleksander W.
    Ebersberger, Ullrich
    Meinel, Felix G.
    Schoepf, U. Joseph
    JACC-CARDIOVASCULAR IMAGING, 2013, 6 (12) : 1239 - 1249
  • [30] Automated Tube Voltage Selection for Radiation Dose Reduction in CT Angiography Using Different Contrast Media Concentrations and a Constant Iodine Delivery Rate
    Kok, Madeleine
    Mihl, Casper
    Seehofnerova, Anna
    Turek, Jakub
    Jost, Gregor
    Pietsch, Hubertus
    Haberland, Ulrike
    Wildberger, Joachim E.
    Das, Marco
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (06) : 1332 - 1338