Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy

被引:31
|
作者
Guinot, P. -G. [1 ]
de Broca, B. [1 ]
Bernard, E. [1 ]
Abou Arab, O. [1 ]
Lorne, E. [1 ,2 ]
Dupont, H. [1 ,2 ]
机构
[1] Amiens Univ Hosp, Anaesthesiol & Crit Care Dept, F-80054 Amiens, France
[2] Jules Verne Univ Picardy, INSERM, ERI12, F-80000 Amiens, France
关键词
anaesthesia; Doppler; intraoperative; laparoscopy; monitoring; stroke volume; INCREASED INTRAABDOMINAL PRESSURE; SYSTEMIC VASCULAR-RESISTANCE; PULSE PRESSURE; CARDIAC-OUTPUT; PNEUMOPERITONEUM; OPTIMIZATION;
D O I
10.1093/bja/aet430
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study was designed to assess the ability of the stroke volume respiratory variation (respSV) determined by oesophageal Doppler monitoring (ODM) to predict the response to volume expansion (VE) during pneumoperitoneum. The predictive value of respSV was evaluated according to the concept of the grey zone. Patients operated on laparoscopy and monitored by ODM were prospectively included. The exclusion criteria were frequent ectopic beats or preoperative arrhythmia, right ventricular failure, and spontaneous breathing. Haemodynamic parameters and oesophageal Doppler indices [stroke volume (SV), peak velocity (PV), cardiac output (CO), corrected flow time (FTc), respiratory variation of PV (respPV) and SV (respSV)] were collected before and after VE. Responders were defined as a 15 increase in SV after VE. Thirty-eight (64) of the 59 patients were responders. A cut-off of 14 respSV predicted fluid responsiveness with an area under the ROC curve (AUC) of 0.92 [95 confidence interval (CI): 0.820.98, P0.0001]. The grey zone of respSV ranged between 13 and 15. With an AUC of 0.71 (95 CI: 0.560.83, P0.005), respPV fairly accurately predicted fluid responsiveness. FTc was unable to accurately predict fluid responsiveness. respSV and respPV predicted fluid responsiveness during laparoscopy under strict physiological conditions. FTc was not predictive of fluid responsiveness during laparoscopy.
引用
收藏
页码:660 / 664
页数:5
相关论文
共 50 条
  • [41] Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness
    Mallat, J.
    Meddour, M.
    Durville, E.
    Lemyze, M.
    Pepy, F.
    Temime, J.
    Vangrunderbeeck, N.
    Tronchon, L.
    Thevenin, D.
    Tavernier, B.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (03) : 449 - 456
  • [42] Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac™ and PiCCOplus™ system
    Hofer, Christoph K.
    Senn, Alban
    Weibel, Luc
    Zollinger, Andreas
    CRITICAL CARE, 2008, 12 (03):
  • [43] Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing One-Lung Ventilation
    Suehiro, Koichi
    Okutani, Ryu
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (05) : 772 - 775
  • [44] Prone position affects stroke volume variation performance in predicting fluid responsiveness in neurosurgical patients
    Berger, K.
    Francony, G.
    Bouzat, P.
    Halle, C.
    Genty, C.
    Oddoux, M.
    Gay, E.
    Albaladejo, P.
    Payen, J. -F.
    MINERVA ANESTESIOLOGICA, 2015, 81 (06) : 628 - 635
  • [45] Stroke volume variation as a predictor of fluid responsiveness in patients undergoing airway pressure release ventilation
    Suehiro, K.
    Rinka, H.
    Ishikawa, J.
    Fuke, A.
    Arimoto, H.
    Miyaichi, T.
    ANAESTHESIA AND INTENSIVE CARE, 2012, 40 (05) : 767 - 772
  • [46] Stroke volume variation as a predictor of fluid responsiveness for cardiac output in patients undergoing cardiac surgery
    Klinzing, S
    Seeber, P
    Schiergens, V
    Sakka, S
    Reinhart, K
    Meier-Hellmann, A
    CRITICAL CARE MEDICINE, 2001, 29 (12) : A56 - A56
  • [47] Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac™ and PiCCOplus™ system
    Christoph K Hofer
    Alban Senn
    Luc Weibel
    Andreas Zollinger
    Critical Care, 12
  • [48] Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis
    Zhongheng Zhang
    Baolong Lu
    Xiaoyan Sheng
    Ni Jin
    Journal of Anesthesia, 2011, 25 : 904 - 916
  • [49] PULSE PRESSURE AND STROKE VOLUME VARIATION ARE GOOD PREDICTORS OF FLUID RESPONSIVENESS IN SEVERE SEPSIS PATIENTS
    Drvar, Z.
    Baronica, R.
    Tomasevic, B.
    Pavlek, M.
    Miric, M.
    Peric, M.
    INTENSIVE CARE MEDICINE, 2012, 38 : S202 - S202
  • [50] Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis
    Zhang, Zhongheng
    Lu, Baolong
    Sheng, Xiaoyan
    Jin, Ni
    JOURNAL OF ANESTHESIA, 2011, 25 (06) : 904 - 916