Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy

被引:31
|
作者
Guinot, P. -G. [1 ]
de Broca, B. [1 ]
Bernard, E. [1 ]
Abou Arab, O. [1 ]
Lorne, E. [1 ,2 ]
Dupont, H. [1 ,2 ]
机构
[1] Amiens Univ Hosp, Anaesthesiol & Crit Care Dept, F-80054 Amiens, France
[2] Jules Verne Univ Picardy, INSERM, ERI12, F-80000 Amiens, France
关键词
anaesthesia; Doppler; intraoperative; laparoscopy; monitoring; stroke volume; INCREASED INTRAABDOMINAL PRESSURE; SYSTEMIC VASCULAR-RESISTANCE; PULSE PRESSURE; CARDIAC-OUTPUT; PNEUMOPERITONEUM; OPTIMIZATION;
D O I
10.1093/bja/aet430
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study was designed to assess the ability of the stroke volume respiratory variation (respSV) determined by oesophageal Doppler monitoring (ODM) to predict the response to volume expansion (VE) during pneumoperitoneum. The predictive value of respSV was evaluated according to the concept of the grey zone. Patients operated on laparoscopy and monitored by ODM were prospectively included. The exclusion criteria were frequent ectopic beats or preoperative arrhythmia, right ventricular failure, and spontaneous breathing. Haemodynamic parameters and oesophageal Doppler indices [stroke volume (SV), peak velocity (PV), cardiac output (CO), corrected flow time (FTc), respiratory variation of PV (respPV) and SV (respSV)] were collected before and after VE. Responders were defined as a 15 increase in SV after VE. Thirty-eight (64) of the 59 patients were responders. A cut-off of 14 respSV predicted fluid responsiveness with an area under the ROC curve (AUC) of 0.92 [95 confidence interval (CI): 0.820.98, P0.0001]. The grey zone of respSV ranged between 13 and 15. With an AUC of 0.71 (95 CI: 0.560.83, P0.005), respPV fairly accurately predicted fluid responsiveness. FTc was unable to accurately predict fluid responsiveness. respSV and respPV predicted fluid responsiveness during laparoscopy under strict physiological conditions. FTc was not predictive of fluid responsiveness during laparoscopy.
引用
收藏
页码:660 / 664
页数:5
相关论文
共 50 条
  • [11] Fluid responsiveness is about stroke volume, and not pulse pressure Yogi: the power of Doppler fluid management and cardiovascular monitoring
    Rob Phillips
    Joe Brierley
    Journal of Clinical Monitoring and Computing, 2015, 29 : 197 - 200
  • [12] Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients
    Monnet, X
    Rienzo, M
    Osman, D
    Anguel, N
    Richard, C
    Pinsky, MR
    Teboul, JL
    INTENSIVE CARE MEDICINE, 2005, 31 (09) : 1195 - 1201
  • [13] Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients
    Xavier Monnet
    Mario Rienzo
    David Osman
    Nadia Anguel
    Christian Richard
    Michael R. Pinsky
    Jean-Louis Teboul
    Intensive Care Medicine, 2005, 31 : 1195 - 1201
  • [14] Predicting fluid responsiveness with stroke volume variation despite multiple extrasystoles
    Cannesson, Maxime
    Nam Phuong Tran
    Cho, Max
    Hatib, Feras
    Michard, Frederic
    CRITICAL CARE MEDICINE, 2012, 40 (01) : 193 - 198
  • [15] Should We Really Use Respiratory Stroke Volume Variation to Assess Fluid Responsiveness in Cardiac Surgical Patients?
    Schweizer, Remi
    Portran, Philippe
    Jacquet-Lagreze, Matthias
    Fellahi, Jean-Luc
    CRITICAL CARE MEDICINE, 2021, 49 (11) : E1191 - E1192
  • [16] Stroke volume averaging for individualized goal-directed fluid therapy with oesophageal Doppler
    Jorgensen, C. C.
    Bundgaard-Nielsen, M.
    Skovgaard, L. T.
    Secher, N. H.
    Kehlet, H.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2009, 53 (01) : 34 - 38
  • [17] A systematic review of pulse pressure variation and stroke volume variation to predict fluid responsiveness during cardiac and thoracic surgery
    Federico Piccioni
    Filippo Bernasconi
    Giulia T. A. Tramontano
    Martin Langer
    Journal of Clinical Monitoring and Computing, 2017, 31 : 677 - 684
  • [18] A systematic review of pulse pressure variation and stroke volume variation to predict fluid responsiveness during cardiac and thoracic surgery
    Piccioni, Federico
    Bernasconi, Filippo
    Tramontano, Giulia T. A.
    Langer, Martin
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (04) : 677 - 684
  • [19] The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery
    Wyffels, P. A. H.
    Sergeant, P.
    Wouters, P. F.
    ANAESTHESIA, 2010, 65 (07) : 704 - 709
  • [20] Stroke volume variation and indexed stroke volume measured using bioreactance predict fluid responsiveness in postoperative children
    Vergnaud, E.
    Vidal, C.
    Verchere, J.
    Miatello, J.
    Meyer, P.
    Carli, P.
    Orliaguet, G.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 114 (01) : 103 - 109