Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy

被引:31
|
作者
Guinot, P. -G. [1 ]
de Broca, B. [1 ]
Bernard, E. [1 ]
Abou Arab, O. [1 ]
Lorne, E. [1 ,2 ]
Dupont, H. [1 ,2 ]
机构
[1] Amiens Univ Hosp, Anaesthesiol & Crit Care Dept, F-80054 Amiens, France
[2] Jules Verne Univ Picardy, INSERM, ERI12, F-80000 Amiens, France
关键词
anaesthesia; Doppler; intraoperative; laparoscopy; monitoring; stroke volume; INCREASED INTRAABDOMINAL PRESSURE; SYSTEMIC VASCULAR-RESISTANCE; PULSE PRESSURE; CARDIAC-OUTPUT; PNEUMOPERITONEUM; OPTIMIZATION;
D O I
10.1093/bja/aet430
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study was designed to assess the ability of the stroke volume respiratory variation (respSV) determined by oesophageal Doppler monitoring (ODM) to predict the response to volume expansion (VE) during pneumoperitoneum. The predictive value of respSV was evaluated according to the concept of the grey zone. Patients operated on laparoscopy and monitored by ODM were prospectively included. The exclusion criteria were frequent ectopic beats or preoperative arrhythmia, right ventricular failure, and spontaneous breathing. Haemodynamic parameters and oesophageal Doppler indices [stroke volume (SV), peak velocity (PV), cardiac output (CO), corrected flow time (FTc), respiratory variation of PV (respPV) and SV (respSV)] were collected before and after VE. Responders were defined as a 15 increase in SV after VE. Thirty-eight (64) of the 59 patients were responders. A cut-off of 14 respSV predicted fluid responsiveness with an area under the ROC curve (AUC) of 0.92 [95 confidence interval (CI): 0.820.98, P0.0001]. The grey zone of respSV ranged between 13 and 15. With an AUC of 0.71 (95 CI: 0.560.83, P0.005), respPV fairly accurately predicted fluid responsiveness. FTc was unable to accurately predict fluid responsiveness. respSV and respPV predicted fluid responsiveness during laparoscopy under strict physiological conditions. FTc was not predictive of fluid responsiveness during laparoscopy.
引用
收藏
页码:660 / 664
页数:5
相关论文
共 50 条
  • [31] Stroke Volume and Systolic Pressure Variation Are Poor Predictors of Fluid Responsiveness During Major Pancreatic Surgery.
    Shakeban, Hassan
    Conlon, Niamh
    Boylan, John
    LIVER TRANSPLANTATION, 2014, 20 : S297 - S297
  • [32] Utility of Uncalibrated Femoral Stroke Volume Variation as a Predictor of Fluid Responsiveness During the Anhepatic Phase of Liver Transplantation
    Shin, Young Hee
    Ko, Justin Sangwook
    Gwak, Mi Sook
    Kim, Gaab Soo
    Lee, Jong Hwan
    Lee, Suk-Koo
    LIVER TRANSPLANTATION, 2011, 17 (01) : 53 - 59
  • [33] Accuracy of stroke volume variation and pulse pressure variation to predict fluid responsiveness in patients with thoracic kyphosis
    Chen, Yu
    Guo, Xiaomei
    Fu, Jiannan
    Dong, Tong
    Liu, Xiaomei
    Lv, Hao
    ANNALS OF PALLIATIVE MEDICINE, 2021, 10 (07) : 7571 - 7578
  • [34] Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis
    Marx, G
    Cope, T
    McCrossan, L
    Swaraj, S
    Cowan, C
    Mostafa, SM
    Wenstone, R
    Leuwer, M
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (02) : 132 - 138
  • [35] Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis
    Cope, T
    Marx, G
    McCrossan, L
    Swaraj, S
    Cowan, C
    Mostafa, SM
    Wenstone, R
    Leuwer, M
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (03) : 410P - 410P
  • [36] Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation
    Biais, M.
    Nouette-Gaulain, K.
    Cottenceau, V.
    Revel, P.
    Sztark, F.
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (06) : 761 - 768
  • [37] Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis
    Lars Øivind Høiseth
    Ingrid Elise Hoff
    Ove Andreas Hagen
    Svein Aslak Landsverk
    Knut Arvid Kirkebøen
    Journal of Clinical Monitoring and Computing, 2015, 29 : 435 - 441
  • [38] Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis
    Hoiseth, Lars Oivind
    Hoff, Ingrid Elise
    Hagen, Ove Andreas
    Landsverk, Svein Aslak
    Kirkeboen, Knut Arvid
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (04) : 435 - 441
  • [39] AGREEMENT IN STROKE VOLUME MEASUREMENTS BETWEEN OESOPHAGEAL DOPPLER AND PULSE CONTOUR ANALYSIS DURING FLUID CHALLENGES IN THE PERI-OPERATIVE PERIOD
    Bedair, Rafik
    Sevenoaks, Hannah
    Conway, Daniel
    Nirmalan, Mahesh
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A101 - A101
  • [40] l Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy
    Kim, Kyung Mi
    Gwak, Mi Sook
    Choi, Soo Joo
    Kim, Myung Hee
    Park, Mi Hye
    Heo, Burn Young
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2013, 65 (03) : 237 - 243