Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy

被引:31
|
作者
Guinot, P. -G. [1 ]
de Broca, B. [1 ]
Bernard, E. [1 ]
Abou Arab, O. [1 ]
Lorne, E. [1 ,2 ]
Dupont, H. [1 ,2 ]
机构
[1] Amiens Univ Hosp, Anaesthesiol & Crit Care Dept, F-80054 Amiens, France
[2] Jules Verne Univ Picardy, INSERM, ERI12, F-80000 Amiens, France
关键词
anaesthesia; Doppler; intraoperative; laparoscopy; monitoring; stroke volume; INCREASED INTRAABDOMINAL PRESSURE; SYSTEMIC VASCULAR-RESISTANCE; PULSE PRESSURE; CARDIAC-OUTPUT; PNEUMOPERITONEUM; OPTIMIZATION;
D O I
10.1093/bja/aet430
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study was designed to assess the ability of the stroke volume respiratory variation (respSV) determined by oesophageal Doppler monitoring (ODM) to predict the response to volume expansion (VE) during pneumoperitoneum. The predictive value of respSV was evaluated according to the concept of the grey zone. Patients operated on laparoscopy and monitored by ODM were prospectively included. The exclusion criteria were frequent ectopic beats or preoperative arrhythmia, right ventricular failure, and spontaneous breathing. Haemodynamic parameters and oesophageal Doppler indices [stroke volume (SV), peak velocity (PV), cardiac output (CO), corrected flow time (FTc), respiratory variation of PV (respPV) and SV (respSV)] were collected before and after VE. Responders were defined as a 15 increase in SV after VE. Thirty-eight (64) of the 59 patients were responders. A cut-off of 14 respSV predicted fluid responsiveness with an area under the ROC curve (AUC) of 0.92 [95 confidence interval (CI): 0.820.98, P0.0001]. The grey zone of respSV ranged between 13 and 15. With an AUC of 0.71 (95 CI: 0.560.83, P0.005), respPV fairly accurately predicted fluid responsiveness. FTc was unable to accurately predict fluid responsiveness. respSV and respPV predicted fluid responsiveness during laparoscopy under strict physiological conditions. FTc was not predictive of fluid responsiveness during laparoscopy.
引用
收藏
页码:660 / 664
页数:5
相关论文
共 50 条
  • [21] Should We Really Use Respiratory Stroke Volume Variation to Assess Fluid Responsiveness in Cardiac Surgical Patients? Reply
    Parke, Rachael
    McGuinness, Shay
    CRITICAL CARE MEDICINE, 2021, 49 (11) : E1192 - E1193
  • [22] Stroke Volume Variation for Prediction of Fluid Responsiveness in Patients Undergoing Gastrointestinal Surgery
    Li, Cheng
    Lin, Fu-qing
    Fu, Shu-kun
    Chen, Guo-qiang
    Yang, Xiao-hu
    Zhu, Chun-yan
    Zhang, Li-jun
    Li, Quan
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2013, 10 (02): : 148 - 155
  • [23] Prediction of Fluid Responsiveness by Stroke Volume Variation in Children Undergoing Fontan Operation
    Song, Yun'an
    Hou, Huiyan
    Bai, Jie
    Gu, Hongbin
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [24] Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery
    Berkenstadt, H
    Margalit, N
    Hadani, M
    Friedman, Z
    Segal, E
    Villa, Y
    Perel, A
    ANESTHESIA AND ANALGESIA, 2001, 92 (04): : 984 - 989
  • [25] STROKE VOLUME VARIATION AS AN INDEX OF FLUID RESPONSIVENESS CAN BE IMPAIRED BY MENTAL STRESS
    Wiszt, R.
    Czippelova, B.
    Krohova, J. Cernanova
    Mazgutova, N.
    Turianikova, Z.
    Lazarova, Z.
    Javorka, M.
    JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 2022, 73 (02): : 277 - 285
  • [26] Pressure controlled ventilation on stroke volume variation as a predictor of fluid responsiveness in patients
    Ye, Weiguang
    Wang, Bin
    Wei, Limin
    Wang, Tianlong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (06): : 10963 - 10970
  • [27] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Zlicar, Marko
    Novak-Jankovic, Vesna
    Blagus, Rok
    Cecconi, Maurizio
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (05) : 825 - 832
  • [28] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Marko Zlicar
    Vesna Novak-Jankovic
    Rok Blagus
    Maurizio Cecconi
    Journal of Clinical Monitoring and Computing, 2018, 32 : 825 - 832
  • [29] Stroke Volume Variation and Pulse Pressure Variation Are Not Useful for Predicting Fluid Responsiveness in Thoracic Surgery
    Jeong, Dae Myoung
    Ahn, Hyun Joo
    Park, Hyo Won
    Yang, Mikyung
    Kim, Jie Ae
    Park, Joohyun
    ANESTHESIA AND ANALGESIA, 2017, 125 (04): : 1158 - 1165
  • [30] The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation
    Myatra, Sheila Nainan
    Prabu, Natesh R.
    Vasishtha, Jigeeshu
    Monnet, Xavier
    Kulkarni, Atul Prabhakar
    Teboul, Jean-Louis
    CRITICAL CARE MEDICINE, 2017, 45 (03) : 415 - 421