Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy

被引:31
|
作者
Guinot, P. -G. [1 ]
de Broca, B. [1 ]
Bernard, E. [1 ]
Abou Arab, O. [1 ]
Lorne, E. [1 ,2 ]
Dupont, H. [1 ,2 ]
机构
[1] Amiens Univ Hosp, Anaesthesiol & Crit Care Dept, F-80054 Amiens, France
[2] Jules Verne Univ Picardy, INSERM, ERI12, F-80000 Amiens, France
关键词
anaesthesia; Doppler; intraoperative; laparoscopy; monitoring; stroke volume; INCREASED INTRAABDOMINAL PRESSURE; SYSTEMIC VASCULAR-RESISTANCE; PULSE PRESSURE; CARDIAC-OUTPUT; PNEUMOPERITONEUM; OPTIMIZATION;
D O I
10.1093/bja/aet430
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study was designed to assess the ability of the stroke volume respiratory variation (respSV) determined by oesophageal Doppler monitoring (ODM) to predict the response to volume expansion (VE) during pneumoperitoneum. The predictive value of respSV was evaluated according to the concept of the grey zone. Patients operated on laparoscopy and monitored by ODM were prospectively included. The exclusion criteria were frequent ectopic beats or preoperative arrhythmia, right ventricular failure, and spontaneous breathing. Haemodynamic parameters and oesophageal Doppler indices [stroke volume (SV), peak velocity (PV), cardiac output (CO), corrected flow time (FTc), respiratory variation of PV (respPV) and SV (respSV)] were collected before and after VE. Responders were defined as a 15 increase in SV after VE. Thirty-eight (64) of the 59 patients were responders. A cut-off of 14 respSV predicted fluid responsiveness with an area under the ROC curve (AUC) of 0.92 [95 confidence interval (CI): 0.820.98, P0.0001]. The grey zone of respSV ranged between 13 and 15. With an AUC of 0.71 (95 CI: 0.560.83, P0.005), respPV fairly accurately predicted fluid responsiveness. FTc was unable to accurately predict fluid responsiveness. respSV and respPV predicted fluid responsiveness during laparoscopy under strict physiological conditions. FTc was not predictive of fluid responsiveness during laparoscopy.
引用
收藏
页码:660 / 664
页数:5
相关论文
共 50 条
  • [1] RESPIRATORY VARIATION OF STROKE VOLUME MEASURED BY OESOPHAGEAL DOPPLER PREDICT FLUID RESPONSIVENESS DURING LAPAROSCOPY
    De Broca, B.
    Abou Arab, O.
    Bernard, E.
    Badoux, L.
    Guinot, P. -G.
    Dupont, H.
    INTENSIVE CARE MEDICINE, 2012, 38 : S150 - S150
  • [2] Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgery
    Guinot, P. -G.
    de Broca, B.
    Abou Arab, O.
    Diouf, M.
    Badoux, L.
    Bernard, E.
    Lorne, E.
    Dupont, H.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (01) : 28 - 33
  • [4] Impact of age on the predictive value of respiratory variation of stroke volume measured by oesophageal doppler
    Guinot, P. -G.
    de Broca, B.
    Petiot, S.
    Abou Arab, O.
    Bernard, E.
    Dupont, H.
    Lorne, E.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2014, 33 : A209 - A210
  • [5] Predictability of the respiratory variation of stroke volume varies according to the definition of fluid responsiveness
    Guinot, P. -G.
    Urbina, B.
    de Broca, B.
    Bernard, E.
    Dupont, H.
    Lorne, E.
    BRITISH JOURNAL OF ANAESTHESIA, 2014, 112 (03) : 580 - 581
  • [6] PREDICTING FLUID RESPONSIVENESS WITH STROKE VOLUME VARIATION (SVV) DURING CARDIAC ARRHYTHMIA
    Headley, Jan
    Hatib, Feras
    Jian, Zhongping
    Roteliuk, Luchy
    Michard, Frederic
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A88 - A88
  • [7] Predicting fluid responsiveness with stroke volume variation (SVV) during cardiac arrhythmia
    Cannesson, M.
    Cho, M.
    Hatib, F.
    Michard, F.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 74 - 75
  • [8] Stroke volume variation as an indicator of fluid responsiveness - In response
    Wiesenack, C
    Keyl, C
    ANESTHESIA AND ANALGESIA, 2004, 98 (01): : 278 - 279
  • [9] Perioperative monitoring of fluid responsiveness after esophageal surgery using stroke volume variation
    Kobayashi, Makoto
    Ko, Masayoshi
    Kimura, Toshimoto
    Meguro, Eiji
    Hayakawa, Yoshiro
    Irinoda, Takashi
    Takagane, Akinori
    EXPERT REVIEW OF MEDICAL DEVICES, 2008, 5 (03) : 311 - 316
  • [10] Fluid responsiveness is about stroke volume, and not pulse pressure Yogi: the power of Doppler fluid management and cardiovascular monitoring
    Phillips, Rob
    Brierley, Joe
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (01) : 197 - 200