Device and technique for extracorporeal blood volume sequestration during hemodialysis

被引:1
|
作者
Wimmer, Juergen
Bachler, Isolde
Haditsch, Bernd
Stadlbauer, Vanessa
Holzer, Herwig
Schneditz, Daniel
机构
[1] Graz Med Univ, Inst Physiol, Ctr Physiol Med, A-8010 Graz, Austria
[2] Graz Med Univ, Div Neurol, Dept Internal Med, A-8010 Graz, Austria
[3] Graz Med Univ, Div Gastroenterol, Dept Internal Med, A-8010 Graz, Austria
关键词
D O I
10.1097/01.mat.0000235812.55055.5b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed a technique for a controlled and reversible volume perturbation of the cardiovascular system during hemodialysis. The capacitance of the extracorporeal circulation was modified by an expansion bag, using separate filling and draining lines connected to postpump and prepump sections of the arterial line segment, respectively. The connection to this bag was manually operated by three-way valves. The volume sequestered into the blood bag was continuously measured by a weighing scale. Filling and draining of the expansion bag was measured in eight patients in two subsequent routine dialysis treatments. Four volume shifts were done in each treatment. Filling and draining rates and times depended on extracorporeal blood flow as well as arterial and venous line pressures. Bag inflow and outflow volumes were 215.8 +/- 28.5 ml/min and 221.6 +/- 37.0 ml/min, respectively. The total volume transiently sequestered in the bag was 479.8 +/- 61.3 ml. The duration of the whole test was 4.5 +/- 0.8 minutes. During filling, residual dialyzer blood flow was transiently reduced to 58.5 +/- 21.6 ml/min and the filtration fraction reached 30 +/- 13%. There were no adverse events such as clotting in the blood bag or in the dialyzer. The method provides rapid, reversible, and safe volume shifts between the patient and the extracorporeal circulation with the potential to elicit a hemodynamic response for characterizing the patient during each dialysis treatment.
引用
收藏
页码:662 / 669
页数:8
相关论文
共 50 条
  • [31] Cardiac output and central blood volume during hemodialysis: Methodology
    Krivitski, NM
    Depner, TA
    ADVANCES IN RENAL REPLACEMENT THERAPY, 1999, 6 (03): : 225 - 232
  • [32] Scattering effect for relative blood volume monitoring during hemodialysis
    Zhou, Lianqiao
    Li, Qinlan
    Wei, Shuang
    Wang, Shugang
    Cui, Jingqiang
    Wang, Guosheng
    Liu, Chong
    Su, Yewang
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 377
  • [33] Magnitude and precision of absolute blood volume estimated during hemodialysis
    Abohtyra, Rammah
    Vincent, Tyrone
    Schneditz, Daniel
    RENAL FAILURE, 2024, 46 (02)
  • [34] Active Circulating Blood Volume During Hemodialysis: A Bench Model
    Hu, Dean
    Krivitski, Nikolai M.
    Salehpour, Fahimeh
    Rivas, Logan
    Chahal, Yaadveer
    Aragon, Michael
    ASAIO JOURNAL, 2022, 68 (07) : 972 - 977
  • [35] INTERSTITIAL CORRECTION OF BLOOD-VOLUME DECREASE DURING HEMODIALYSIS
    KOUW, PM
    DEVRIES, PMJM
    OE, PL
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1989, 12 (10): : 626 - 631
  • [36] Central, peripheral, and other blood volume changes during hemodialysis
    Prakash, S
    Reddan, D
    Heidenheim, AP
    Kianfar, C
    Lindsay, RM
    ASAIO JOURNAL, 2002, 48 (04) : 379 - 382
  • [37] BLOOD PRESSURE VOLUME RENIN RELATIONSHIPS DURING MAINTENANCE HEMODIALYSIS
    WINER, RL
    SHAH, GM
    DANVIRIYASUP, K
    VANDERHOEK, C
    DRAYER, JIM
    WEBER, MA
    CLINICAL RESEARCH, 1985, 33 (01): : A85 - A85
  • [38] Residual Red Blood Cell Volume in Extracorporeal Blood Circuit after Hemodialysis: A Single-Center Study
    Hong, Sae-Yong
    Beck, Nam-Seon
    Lee, Jong-Ran
    Jeon, Eun-Kyoung
    Kim, So-Min
    Park, Sol-Rim
    Park, Ok-Ju
    Hong, Jungrak
    Im, Joung-Il
    BLOOD PURIFICATION, 2025, 54 (01) : 54 - 61
  • [39] Dialysate temperature is not the sole determinant of extracorporeal blood cooling during hemodialysis (HD)
    Morris, AT
    Schneditz, D
    Fan, ZH
    Kaufman, AM
    Levin, NW
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A0840 - A0840
  • [40] IS THE ULTRAFILTRATION (UF)-PULSE TECHNIQUE TO MEASURE CIRCULATING BLOOD-VOLUME (BVCIRC) DURING HEMODIALYSIS (HD) RELIABLE
    SCHNEDITZ, D
    ROOB, J
    POGGLITSCH, H
    KENNER, T
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 528 - 528