Device and technique for extracorporeal blood volume sequestration during hemodialysis

被引:1
|
作者
Wimmer, Juergen
Bachler, Isolde
Haditsch, Bernd
Stadlbauer, Vanessa
Holzer, Herwig
Schneditz, Daniel
机构
[1] Graz Med Univ, Inst Physiol, Ctr Physiol Med, A-8010 Graz, Austria
[2] Graz Med Univ, Div Neurol, Dept Internal Med, A-8010 Graz, Austria
[3] Graz Med Univ, Div Gastroenterol, Dept Internal Med, A-8010 Graz, Austria
关键词
D O I
10.1097/01.mat.0000235812.55055.5b
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed a technique for a controlled and reversible volume perturbation of the cardiovascular system during hemodialysis. The capacitance of the extracorporeal circulation was modified by an expansion bag, using separate filling and draining lines connected to postpump and prepump sections of the arterial line segment, respectively. The connection to this bag was manually operated by three-way valves. The volume sequestered into the blood bag was continuously measured by a weighing scale. Filling and draining of the expansion bag was measured in eight patients in two subsequent routine dialysis treatments. Four volume shifts were done in each treatment. Filling and draining rates and times depended on extracorporeal blood flow as well as arterial and venous line pressures. Bag inflow and outflow volumes were 215.8 +/- 28.5 ml/min and 221.6 +/- 37.0 ml/min, respectively. The total volume transiently sequestered in the bag was 479.8 +/- 61.3 ml. The duration of the whole test was 4.5 +/- 0.8 minutes. During filling, residual dialyzer blood flow was transiently reduced to 58.5 +/- 21.6 ml/min and the filtration fraction reached 30 +/- 13%. There were no adverse events such as clotting in the blood bag or in the dialyzer. The method provides rapid, reversible, and safe volume shifts between the patient and the extracorporeal circulation with the potential to elicit a hemodynamic response for characterizing the patient during each dialysis treatment.
引用
收藏
页码:662 / 669
页数:8
相关论文
共 50 条
  • [21] Pattern of blood volume monitoring (BVM) during hemodialysis
    Tabei, Kaoru
    Ando, Katsunobu
    Sakuma, Yuki
    Suzuki, Keiko
    Mori, Honami
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 : 424 - 424
  • [22] A SIMPLIFIED TECHNIQUE FOR EXTRACORPOREAL BYPASS IN HEMODIALYSIS
    TSUCHIDA, S
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1968, 95 (03): : 261 - 269
  • [23] HOMOLOGOUS BLOOD SYNDROME DURING EXTRACORPOREAL CIRCULATION IN MAN - PHENOMENA OF SEQUESTRATION AND DESEQUESTRATION
    LITWAK, RS
    WISOFF, BG
    SLONIM, R
    GADBOYS, HL
    CIRCULATION, 1962, 26 (04) : 752 - &
  • [24] Management of blood volume during extracorporeal circulation in cardiac surgery
    Blaffart, F.
    Defraigne, J. -O.
    IRBM, 2010, 31 : S22 - S26
  • [25] BLOOD VOLUME AND HAEMODILUTION IN EXTRACORPOREAL CIRCULATION - CHANGES DURING PERFUSION
    GUHA, H
    RAISON, JCA
    THORAX, 1966, 21 (02) : 150 - &
  • [26] FLUID VOLUME CHANGES DURING HEMODIALYSIS MONITORED WITH THE IMPEDANCE TECHNIQUE
    TEDNER, B
    LINS, LE
    ARTIFICIAL ORGANS, 1985, 9 (04) : 416 - 420
  • [27] A sequestration test to examine individual blood pressure regulation during hemodialysis (HD)
    Haditsch, B
    Wimmer, J
    Bachler, I
    Holzer, H
    Schneditz, D
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2006, 29 (05): : 528 - 528
  • [28] MODIFIED TECHNIQUE OF ARTIFICIAL HEMODIALYSIS - PRELIMINARY CIRCULATION OF BLOOD IN ARTIFICIAL KIDNEY PRIOR TO EXTRACORPOREAL HEMODIALYSIS - TECHNICAL ASPECTS
    COLMORE, JP
    CZERWINSKI, AW
    DRAKE, JW
    JOURNAL OF UROLOGY, 1965, 93 (02): : 122 - +
  • [29] Effect of high and low ultrafiltration volume during hemodialysis on relative blood volume
    Dasselaar, JJ
    de Jong, PE
    Huisman, RM
    Franssen, CFM
    ASAIO JOURNAL, 2006, 52 (02) : 169 - 173
  • [30] NONINVASIVE MEASUREMENT OF BLOOD-VOLUME AND EXTRACELLULAR FLUID VOLUME DURING HEMODIALYSIS
    DEVRIES, JPPM
    KOUW, PM
    VANDERMEER, BJM
    OE, PL
    DONKER, AJM
    DEVRIES, PMJM
    KIDNEY INTERNATIONAL, 1993, 43 (04) : 969 - 970