Detecting Mechanical Alternans Utilizing Photoplethysmography

被引:1
|
作者
Besleaga, Tudor [1 ]
Canichella, Antonio [2 ]
Toschi, Nicola [2 ]
Demosthenous, Andreas [3 ]
Lambiase, Pier D. [4 ]
Orini, Michele [4 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, London, England
[2] Univ Rome, Dept Biomed & Prevent, Med Phys, Rome, Italy
[3] UCL, Dept Elect & Elect Engn, London, England
[4] UCL, Inst Cardiovasc Sci, London, England
关键词
CARDIAC ALTERNANS;
D O I
10.22489/CinC.2018.212
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Mechanical alternans (M4) is a biomarker associated with mortality in heart failure patients. Its detection through continuous blood pressure (BP) monitoring is costly and impractical. In this work, we propose the use of photoplethysmography (PPG) as a non-invasive solution for MA detection. Continuous invasive BP and PPG were recorded and analyzed during ventricular pacing in 10 patients. The presence of MA was evaluated in BP and in features characterizing the PPG pulse morphology. Mechanical alternans was defined as an alternation in maximum dP/dt for a duration of 20 consecutive heart beats or more. Mechanical alternans was observed in BP in 5 patients (50%). The PPG-based MA surrogates showing the highest detection accuracy, were the maximum of the first derivative of the PPG pulse (V'(M)), and the pulse amplitude (A). Both features allow detection of MA positive patients with 100% sensitivity and 100% specificity. The magnitude of MA was correlated between BP and V'( )(M)PPG (R=0.92, p<0.001) and between BP and A PPG (R=0.89, p<0.001). In conclusion, MA can be accurately detected noninvasively through the PPG.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Sympathetic influences on electrical and mechanical alternans in the canine heart
    Euler, DE
    Guo, HS
    Olshansky, B
    CARDIOVASCULAR RESEARCH, 1996, 32 (05) : 854 - 860
  • [42] A SIMPLE ELECTRICAL MECHANICAL MODEL OF THE HEART APPLIED TO THE STUDY OF ELECTRICAL MECHANICAL ALTERNANS
    CLANCY, EA
    SMITH, JM
    COHEN, RJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (06) : 551 - 560
  • [43] Prominent J-wave and T-wave alternans associated with mechanical alternans in a patient with takotsubo cardiomyopathy
    Hojo, Rintaro
    Fukamizu, Seiji
    Kitamura, Takeshi
    Komiyama, Kota
    Tanabe, Yasuhiro
    Tejima, Tamotsu
    Nishizaki, Mitsuhiro
    Sakurada, Harumizu
    Hiraoka, Masayasu
    JOURNAL OF ARRHYTHMIA, 2015, 31 (01) : 43 - 46
  • [44] Detecting Atrial Fibrillation and Atrial Flutter in Daily Life Using Photoplethysmography Data
    Eerikainen, Linda M.
    Bonomi, Alberto G.
    Schipper, Fons
    Dekker, Lukas R. C.
    de Morree, Helma M.
    Vullings, Rik
    Aarts, Ronald M.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (06) : 1610 - 1618
  • [45] Accuracy of wristwatch-type photoplethysmography in detecting atrial fibrillation in daily life
    Nonoguchi, Noriko Matsushita
    Soejima, Kyoko
    Goda, Ayumi
    Nishimura, Kunihiro
    Onozuka, Daisuke
    Fujita, Shin
    Koyama, Fumio
    Takano, Yuichi
    Iguchi, Shiho
    Sato, Hideki
    Mohri, Takato
    Katusme, Yumi
    Tashiro, Mika
    Hoshida, Kyoko
    Miwa, Yosuke
    Togashi, Ikuko
    Ueda, Akiko
    Sato, Toshiaki
    Kohno, Takashi
    EUROPEAN HEART JOURNAL - DIGITAL HEALTH, 2022, 3 (03): : 455 - 464
  • [46] A unified procedure for detecting, quantifying, and validating electrocardiogram T-wave alternans
    Naseri, H.
    Pourkhajeh, H.
    Homaeinezhad, M. R.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2013, 51 (09) : 1031 - 1042
  • [47] A unified procedure for detecting, quantifying, and validating electrocardiogram T-wave alternans
    H. Naseri
    H. Pourkhajeh
    M. R. Homaeinezhad
    Medical & Biological Engineering & Computing, 2013, 51 : 1031 - 1042
  • [48] Variations in arterial blood pressure and photoplethysmography during mechanical ventilation
    Natalini, Giuseppe
    Rosano, Antonio
    Franceschetti, Maria E.
    Facchetti, Paola
    Bernardini, Achille
    ANESTHESIA AND ANALGESIA, 2006, 103 (05): : 1182 - 1188
  • [49] INCOMPLETE RELAXATION IN THE GENESIS OF MYOCARDIAL MECHANICAL ALTERNANS - EFFECT OF DOBUTAMINE
    NWASOKWA, ON
    FASEB JOURNAL, 1995, 9 (03): : A352 - A352
  • [50] Mechanical Alternans Detected by Doppler-Derived dP/dt
    Garcia-Lledo, Alberto
    San Martin, Miguel A.
    Diaz-Caraballo, Eva
    Balaguer, Javier
    REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (09): : 1100 - 1101