Detecting Mechanical Alternans Utilizing Photoplethysmography

被引:1
|
作者
Besleaga, Tudor [1 ]
Canichella, Antonio [2 ]
Toschi, Nicola [2 ]
Demosthenous, Andreas [3 ]
Lambiase, Pier D. [4 ]
Orini, Michele [4 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, London, England
[2] Univ Rome, Dept Biomed & Prevent, Med Phys, Rome, Italy
[3] UCL, Dept Elect & Elect Engn, London, England
[4] UCL, Inst Cardiovasc Sci, London, England
关键词
CARDIAC ALTERNANS;
D O I
10.22489/CinC.2018.212
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Mechanical alternans (M4) is a biomarker associated with mortality in heart failure patients. Its detection through continuous blood pressure (BP) monitoring is costly and impractical. In this work, we propose the use of photoplethysmography (PPG) as a non-invasive solution for MA detection. Continuous invasive BP and PPG were recorded and analyzed during ventricular pacing in 10 patients. The presence of MA was evaluated in BP and in features characterizing the PPG pulse morphology. Mechanical alternans was defined as an alternation in maximum dP/dt for a duration of 20 consecutive heart beats or more. Mechanical alternans was observed in BP in 5 patients (50%). The PPG-based MA surrogates showing the highest detection accuracy, were the maximum of the first derivative of the PPG pulse (V'(M)), and the pulse amplitude (A). Both features allow detection of MA positive patients with 100% sensitivity and 100% specificity. The magnitude of MA was correlated between BP and V'( )(M)PPG (R=0.92, p<0.001) and between BP and A PPG (R=0.89, p<0.001). In conclusion, MA can be accurately detected noninvasively through the PPG.
引用
收藏
页数:4
相关论文
共 50 条
  • [11] DIASTOLIC OVERLOAD IN MECHANICAL VENTRICULAR ALTERNANS
    SANCETTA, SM
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1955, 46 (03): : 342 - 347
  • [12] DOPPLER ECHOCARDIOGRAPHIC FEATURES OF MECHANICAL ALTERNANS
    SCHUSTER, AH
    NANDA, NC
    AMERICAN HEART JOURNAL, 1984, 107 (03) : 580 - 583
  • [13] Mechanical Alternans Associated With Ventricular Tachyarrhythmias
    Kim, Robert
    Schulman, Steven P.
    McLean, Rhondalyn C.
    Wittstein, Ilan S.
    Cingolani, Oscar H.
    Robinson, Elizabeth A.
    Brinker, Jeffrey A.
    Henrikson, Charles A.
    Calkins, Hugh G.
    Berger, Ronald D.
    Tereshchenko, Larisa G.
    CIRCULATION, 2010, 122 (21)
  • [14] MECHANICAL PULSUS ALTERNANS FOLLOWING MYOCARDITIS
    WALLNOFE.H
    JETSCHGO, G
    HERZ KREISLAUF, 1973, 5 (01): : 16 - 19
  • [15] Mechanical perturbation control of cardiac alternans
    Hazim, Azzam
    Belhamadia, Youssef
    Dubljevic, Stevan
    PHYSICAL REVIEW E, 2018, 97 (05)
  • [16] Automatic sleep staging system utilizing photoplethysmography: a validation study
    Kawada, Tomoyuki
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2024, 20 (06): : 1019 - 1019
  • [17] Utilizing Data from a Sensorless AC Variable Speed Drive for Detecting Mechanical Misalignments
    Abusaad, Samieh
    Benghozzi, Ahmed
    Shao, Yimin
    Gu, Fengshou
    Ball, Andrew
    DAMAGE ASSESSMENT OF STRUCTURES X, PTS 1 AND 2, 2013, 569-570 : 465 - +
  • [18] ECHOCARDIOGRAPHY IN MECHANICAL ALTERNANS - WITH A NOTE ON FINDINGS IN DISCORDANT ALTERNANS WITHIN LEFT-VENTRICLE
    DCRUZ, I
    COHEN, HC
    PRABHU, R
    GLICK, G
    CIRCULATION, 1976, 54 (01) : 97 - 108
  • [19] A novel hardware implementation for detecting respiration rate using photoplethysmography
    Prinable, Joseph
    Jones, Peter
    Thamrin, Cindy
    McEwan, Alistair
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 726 - 729
  • [20] Quantifying tissue mechanical properties using photoplethysmography
    Akl, Tony J.
    Wilson, Mark A.
    Ericson, M. Nance
    Cote, Gerard L.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (07): : 2362 - 2375