Detecting Mechanical Alternans Utilizing Photoplethysmography

被引:1
|
作者
Besleaga, Tudor [1 ]
Canichella, Antonio [2 ]
Toschi, Nicola [2 ]
Demosthenous, Andreas [3 ]
Lambiase, Pier D. [4 ]
Orini, Michele [4 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, London, England
[2] Univ Rome, Dept Biomed & Prevent, Med Phys, Rome, Italy
[3] UCL, Dept Elect & Elect Engn, London, England
[4] UCL, Inst Cardiovasc Sci, London, England
关键词
CARDIAC ALTERNANS;
D O I
10.22489/CinC.2018.212
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Mechanical alternans (M4) is a biomarker associated with mortality in heart failure patients. Its detection through continuous blood pressure (BP) monitoring is costly and impractical. In this work, we propose the use of photoplethysmography (PPG) as a non-invasive solution for MA detection. Continuous invasive BP and PPG were recorded and analyzed during ventricular pacing in 10 patients. The presence of MA was evaluated in BP and in features characterizing the PPG pulse morphology. Mechanical alternans was defined as an alternation in maximum dP/dt for a duration of 20 consecutive heart beats or more. Mechanical alternans was observed in BP in 5 patients (50%). The PPG-based MA surrogates showing the highest detection accuracy, were the maximum of the first derivative of the PPG pulse (V'(M)), and the pulse amplitude (A). Both features allow detection of MA positive patients with 100% sensitivity and 100% specificity. The magnitude of MA was correlated between BP and V'( )(M)PPG (R=0.92, p<0.001) and between BP and A PPG (R=0.89, p<0.001). In conclusion, MA can be accurately detected noninvasively through the PPG.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] PHOTOPLETHYSMOGRAPHY IN STUDY OF MECHANICAL PROPERTIES OF BLOOD VESSELS
    URETZKY, G
    PALTI, Y
    HAREFUAH, 1974, 86 (01) : 1 - 5
  • [22] ELECTRICAL AND MECHANICAL ALTERNANS WITH ORTHODROMIC TACHYCARDIA ONSET
    CROSSON, JE
    DUNNIGAN, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (05): : 416 - 416
  • [23] Mechanical alternans in patients with chronic heart failure
    Kodama, M
    Kato, K
    Hirono, S
    Okura, Y
    Hanawa, H
    Ito, M
    Fuse, K
    Shiono, T
    Watanabe, K
    Aizawa, Y
    JOURNAL OF CARDIAC FAILURE, 2001, 7 (02) : 138 - 145
  • [24] ELECTROPHYSIOLOGIC ASPECTS OF POSTEXTRASYSTOLIC POTENTIATION AND MECHANICAL ALTERNANS
    EDMANDS, RE
    GREENSPA.K
    FISCH, C
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1966, 68 (05): : 870 - &
  • [25] Control of cardiac alternans by mechanical and electrical feedback
    Yapari, Felicia
    Deshpande, Dipen
    Belhamadia, Youssef
    Dubljevic, Stevan
    PHYSICAL REVIEW E, 2014, 90 (01):
  • [26] Total mechanical alternans in a patient with cardiac tamponade
    Rothfeld, JM
    Luetmer, P
    Tischler, MD
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1998, 15 (05): : 507 - 508
  • [27] A Miniaturized Single-Chip Oximetry Module Utilizing Reflectance Photoplethysmography
    Bai, Zhongbo
    Chen, Xiang
    Li, Jin
    2017 10TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI), 2017,
  • [28] Utilizing lateral current spreading in multijunction solar cells: An alternative approach to detecting mechanical defects
    Zimmermann, C. G.
    JOURNAL OF APPLIED PHYSICS, 2006, 100 (02)
  • [29] Accuracy of Reflectance Photoplethysmography on detecting Cuff-Induced Vascular Occlusions
    Abay, T. Y.
    Kyriacou, P. A.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 861 - 864
  • [30] Detecting Fake Finger-Vein Data Using Remote Photoplethysmography
    Bok, Jin Yeong
    Suh, Kun Ha
    Lee, Eui Chul
    ELECTRONICS, 2019, 8 (09)