Detecting Mechanical Alternans Utilizing Photoplethysmography

被引:1
|
作者
Besleaga, Tudor [1 ]
Canichella, Antonio [2 ]
Toschi, Nicola [2 ]
Demosthenous, Andreas [3 ]
Lambiase, Pier D. [4 ]
Orini, Michele [4 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, London, England
[2] Univ Rome, Dept Biomed & Prevent, Med Phys, Rome, Italy
[3] UCL, Dept Elect & Elect Engn, London, England
[4] UCL, Inst Cardiovasc Sci, London, England
关键词
CARDIAC ALTERNANS;
D O I
10.22489/CinC.2018.212
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Mechanical alternans (M4) is a biomarker associated with mortality in heart failure patients. Its detection through continuous blood pressure (BP) monitoring is costly and impractical. In this work, we propose the use of photoplethysmography (PPG) as a non-invasive solution for MA detection. Continuous invasive BP and PPG were recorded and analyzed during ventricular pacing in 10 patients. The presence of MA was evaluated in BP and in features characterizing the PPG pulse morphology. Mechanical alternans was defined as an alternation in maximum dP/dt for a duration of 20 consecutive heart beats or more. Mechanical alternans was observed in BP in 5 patients (50%). The PPG-based MA surrogates showing the highest detection accuracy, were the maximum of the first derivative of the PPG pulse (V'(M)), and the pulse amplitude (A). Both features allow detection of MA positive patients with 100% sensitivity and 100% specificity. The magnitude of MA was correlated between BP and V'( )(M)PPG (R=0.92, p<0.001) and between BP and A PPG (R=0.89, p<0.001). In conclusion, MA can be accurately detected noninvasively through the PPG.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] The Interval-force Relationship in Patients with Mechanical Alternans
    Kashimura, Ken
    Obata, Hiroaki
    Ito, Masahiro
    Hirono, Satoru
    Hanawa, Haruo
    Kodama, Makoto
    JOURNAL OF CARDIAC FAILURE, 2012, 18 (10) : S187 - S187
  • [32] SYMPATHETIC INFLUENCES ON MECHANICAL AND ELECTRICAL ALTERNANS IN THE CANINE HEART
    EULER, DE
    GUO, HS
    OLSHANSKY, B
    CIRCULATION, 1995, 92 (08) : 635 - 635
  • [33] Mechanisms Underlying Electro-Mechanical Cardiac Alternans
    Echebarria, Blas
    Alvarez-Lacalle, Enric
    Cantalapiedra, Inma R.
    Penaranda, Angelina
    NONLINEAR DYNAMICS IN BIOLOGICAL SYSTEMS, 2016, 7 : 113 - 128
  • [34] EFFECT OF PACING RATE AND INTENSITY ON MECHANICAL ALTERNANS AMPLITUDE
    SIDERIS, DA
    NANAS, JN
    PAPALAMBROU, J
    MOULOPOULOS, SD
    JOURNAL OF ELECTROCARDIOLOGY, 1981, 14 (03) : 289 - 293
  • [35] Linkage between mechanical alternans and ST-T electrical alternans in patients with chronic heart failure
    Kodama, M
    Hayashi, M
    Tachikawa, H
    Kashimura, T
    Aizawa, Y
    Watanabe, K
    Nakazawa, M
    EUROPEAN HEART JOURNAL, 2002, 23 : 406 - 406
  • [36] EFFECT OF MECHANICAL ALTERNANS ON CORONARY HEMODYNAMICS DURING TACHYCARDIAS
    CORDAY, E
    SERRUYA, A
    CARVALHO, M
    VYDEN, JK
    GOLD, H
    CIRCULATION, 1967, 36 (4S2) : II91 - &
  • [37] ANALYSIS OF MECHANICAL ALTERNANS IN RABBIT PAPILLARY-MUSCLE
    WOHLFART, B
    ACTA PHYSIOLOGICA SCANDINAVICA, 1982, 115 (04): : 405 - 414
  • [38] MECHANICAL ALTERNANS AND STAIRCASE PHENOMENON IN DOG PAPILLARY MUSCLE
    NAYLER, WG
    ROBERTSON, PG
    AMERICAN HEART JOURNAL, 1965, 70 (04) : 494 - +
  • [39] Augmented Mechanical Alternans after Premature Ventricular Contraction
    Kurisu, Satoshi
    Inoue, Ichiro
    Kawagoe, Takuji
    INTERNAL MEDICINE, 2010, 49 (02) : 197 - 198
  • [40] BEAT BY BEAT VARIATIONS IN RATE AND EXTENT OF MECHANICAL RESTITUTION DURING MECHANICAL ALTERNANS
    SPENCER, CI
    LAB, MJ
    SEED, WA
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1992, 24 : S49 - S49