IN VITRO STUDY OF THE PULP CHAMBER TEMPERATURE RISE DURING LIGHT-ACTIVATED BLEACHING

被引:22
|
作者
Carrasco, Thaise Graciele [1 ]
Carrasco-Guerisoli, Laise Daniela [1 ]
Froner, Izabel Cristina [1 ]
机构
[1] Univ Sao Paulo, Dent Sch Ribeirao Preto, Dept Restorat Dent, Ribeirao Preto, SP, Brazil
关键词
Tooth bleaching; Dental pulp cavity;
D O I
10.1590/S1678-77572008000500010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35% hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1% significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38 +/- 0.66 degrees C). The LED unit produced the lowest temperature increase (0.29 +/- 0.13 degrees C); but there was no significant difference between LED unit and LED-laser system (0.35 +/- 0.15 degrees C) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41 +/- 0.64 degrees C), and LED-laser system the lowest (0.33 +/- 0.12 degrees C); however, there was no difference between LED-laser system and LED unit (0.44 +/- 0.11 degrees C). LED and LED-laser system did not differ significantly from each other regardless the temperature rise occurred with or without bleaching agent application. It may be concluded that during light-activated tooth bleaching, with or without the bleaching agent, halogen light promoted higher pulp chamber temperature rise than LED unit and LED-laser system. The tested light-curing units provided increases in the pulp chamber temperature that were compatible with pulpal health.
引用
收藏
页码:355 / 359
页数:5
相关论文
共 50 条
  • [1] Effect of light-activated bleaching on pulp chamber temperature rise: An in vitro study
    Kivanc, Bagdagul Helvacioglu
    Arisu, Hacer Deniz
    Ulusoy, Ozgur Ilke Atasoy
    Saglam, Baran Can
    Gorgul, Guliz
    [J]. AUSTRALIAN ENDODONTIC JOURNAL, 2012, 38 (02) : 76 - 79
  • [2] Temperature rise during experimental light-activated bleaching
    Klaric, Eva
    Rakic, Mario
    Sever, Ivan
    Tarle, Zrinka
    [J]. LASERS IN MEDICAL SCIENCE, 2015, 30 (02) : 567 - 576
  • [3] Pulpal temperature rise during light-activated bleaching
    Eldeniz, AU
    Usumez, A
    Usumez, S
    Ozturk, N
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (02) : 254 - 259
  • [4] Temperature rise during experimental light-activated bleaching
    Eva Klaric
    Mario Rakic
    Ivan Sever
    Zrinka Tarle
    [J]. Lasers in Medical Science, 2015, 30 : 567 - 576
  • [5] Temperature rise in pulp and gel during laser-activated bleaching: in vitro
    Sari, Tugrul
    Celik, Gozde
    Usumez, Aslihan
    [J]. LASERS IN MEDICAL SCIENCE, 2015, 30 (02) : 577 - 582
  • [6] Temperature rise in pulp and gel during laser-activated bleaching: in vitro
    Tugrul Sari
    Gozde Celik
    Aslıhan Usumez
    [J]. Lasers in Medical Science, 2015, 30 : 577 - 582
  • [7] Temperature rise in the pulp chamber during different stripping procedures - An in vitro study
    Baysal, Asli
    Uysal, Tancan
    Usumez, Serdar
    [J]. ANGLE ORTHODONTIST, 2007, 77 (03) : 478 - 482
  • [8] The effect of laser-activated bleaching with 445 nm and 970 nm diode lasers on pulp chamber temperature rise: an in vitro study
    Saberi, Sogol
    Shahabi, Sima
    Tohidkhah, Saba
    Jafarnia, Shiva
    Pedram, Parham
    [J]. LASER PHYSICS, 2021, 31 (05)
  • [9] Temperature rise during polymerization of light-activated resin composites
    Shortall, AC
    Harrington, E
    [J]. JOURNAL OF ORAL REHABILITATION, 1998, 25 (12) : 908 - 913
  • [10] An in vitro thermal analysis during different light-activated hydrogen peroxide bleaching
    Kabbach, W.
    Zezell, D. M.
    Bandeca, M. C.
    Pereira, T. M.
    Andrade, M. F.
    [J]. LASER PHYSICS, 2010, 20 (09) : 1833 - 1837