IN VITRO STUDY OF THE PULP CHAMBER TEMPERATURE RISE DURING LIGHT-ACTIVATED BLEACHING

被引:22
|
作者
Carrasco, Thaise Graciele [1 ]
Carrasco-Guerisoli, Laise Daniela [1 ]
Froner, Izabel Cristina [1 ]
机构
[1] Univ Sao Paulo, Dent Sch Ribeirao Preto, Dept Restorat Dent, Ribeirao Preto, SP, Brazil
关键词
Tooth bleaching; Dental pulp cavity;
D O I
10.1590/S1678-77572008000500010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35% hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1% significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38 +/- 0.66 degrees C). The LED unit produced the lowest temperature increase (0.29 +/- 0.13 degrees C); but there was no significant difference between LED unit and LED-laser system (0.35 +/- 0.15 degrees C) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41 +/- 0.64 degrees C), and LED-laser system the lowest (0.33 +/- 0.12 degrees C); however, there was no difference between LED-laser system and LED unit (0.44 +/- 0.11 degrees C). LED and LED-laser system did not differ significantly from each other regardless the temperature rise occurred with or without bleaching agent application. It may be concluded that during light-activated tooth bleaching, with or without the bleaching agent, halogen light promoted higher pulp chamber temperature rise than LED unit and LED-laser system. The tested light-curing units provided increases in the pulp chamber temperature that were compatible with pulpal health.
引用
收藏
页码:355 / 359
页数:5
相关论文
共 50 条
  • [41] In vitro peroxide penetration into the pulp chamber from newer bleaching products
    Gökay, O
    Müjdeci, A
    Algin, E
    INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (08) : 516 - 520
  • [42] Effect of Bleaching Gel Viscosity on Tooth Whitening Efficacy and Pulp Chamber Penetration: An In Vitro Study
    Kwon, S. R.
    Pallavi, F. N. U.
    Shi, Y.
    Oyoyo, U.
    Mohraz, A.
    Li, Y.
    OPERATIVE DENTISTRY, 2018, 43 (03) : 326 - 334
  • [43] In vitro comparison of an Er:YAG laser-activated bleaching system with different light-activated bleaching systems for color change, surface roughness, and enamel bond strength
    Ergin, Esra
    Yazici, A. Ruya
    Kalender, Bercem
    Usumez, Aslihan
    Ertan, Atilla
    Gorucu, Jale
    Sari, Tugrul
    LASERS IN MEDICAL SCIENCE, 2018, 33 (09) : 1913 - 1918
  • [44] In vitro comparison of an Er:YAG laser-activated bleaching system with different light-activated bleaching systems for color change, surface roughness, and enamel bond strength
    Esra Ergin
    A. Ruya Yazici
    Bercem Kalender
    Aslihan Usumez
    Atilla Ertan
    Jale Gorucu
    Tugrul Sari
    Lasers in Medical Science, 2018, 33 : 1913 - 1918
  • [45] Temperature Changes of Pulp Chamber during In Vitro Laser Welding of Orthodontic Attachments
    Isman, Eren
    Oksayan, Ridvan
    Sokucu, Oral
    Usumez, Serdar
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [46] Enamel and Dentin Microhardness and Chemical Composition After Experimental Light-activated Bleaching
    Klaric, E.
    Rakic, Mario
    Sever, I.
    Milat, O.
    Par, M.
    Tarle, Z.
    OPERATIVE DENTISTRY, 2015, 40 (04) : E132 - E141
  • [47] Comparison of temperature changes in the pulp chamber induced by various light curing units, in vitro
    Yazici, AR
    Müftü, A
    Kugel, G
    Perry, RD
    OPERATIVE DENTISTRY, 2006, 31 (02) : 261 - 265
  • [48] Coronal resistance to fracture of endodontically treated teeth submitted to light-activated bleaching
    da Silva Pobbe, Priscila de Oliveira
    Viapiana, Raqueli
    Souza-Gabriel, Aline Evangelista
    Marchesan, Melissa Andreia
    Sousa-Neto, Manoel Damiao
    Correa Silva-Sousa, Yara Teresinha
    Silva, Ricardo Gariba
    JOURNAL OF DENTISTRY, 2008, 36 (11) : 935 - 939
  • [49] INVESTIGATION OF THE TEMPERATURE RISE PRODUCED IN THE PULP CHAMBER BY OPERATIVE PROCEDURES
    MEREDITH, N
    WATTS, A
    PATERSON, RC
    STRANG, R
    JOURNAL OF DENTAL RESEARCH, 1984, 63 (04) : 511 - 511
  • [50] TEMPERATURE RISE IN PULP CHAMBER DURING FABRICATION OF TEMPORARY SELF-CURING RESIN CROWNS
    GRAJOWER, R
    SHAHARBANI, S
    KAUFMAN, E
    JOURNAL OF PROSTHETIC DENTISTRY, 1979, 41 (05): : 535 - 540