IN VITRO STUDY OF THE PULP CHAMBER TEMPERATURE RISE DURING LIGHT-ACTIVATED BLEACHING

被引:22
|
作者
Carrasco, Thaise Graciele [1 ]
Carrasco-Guerisoli, Laise Daniela [1 ]
Froner, Izabel Cristina [1 ]
机构
[1] Univ Sao Paulo, Dent Sch Ribeirao Preto, Dept Restorat Dent, Ribeirao Preto, SP, Brazil
关键词
Tooth bleaching; Dental pulp cavity;
D O I
10.1590/S1678-77572008000500010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35% hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1% significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38 +/- 0.66 degrees C). The LED unit produced the lowest temperature increase (0.29 +/- 0.13 degrees C); but there was no significant difference between LED unit and LED-laser system (0.35 +/- 0.15 degrees C) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41 +/- 0.64 degrees C), and LED-laser system the lowest (0.33 +/- 0.12 degrees C); however, there was no difference between LED-laser system and LED unit (0.44 +/- 0.11 degrees C). LED and LED-laser system did not differ significantly from each other regardless the temperature rise occurred with or without bleaching agent application. It may be concluded that during light-activated tooth bleaching, with or without the bleaching agent, halogen light promoted higher pulp chamber temperature rise than LED unit and LED-laser system. The tested light-curing units provided increases in the pulp chamber temperature that were compatible with pulpal health.
引用
收藏
页码:355 / 359
页数:5
相关论文
共 50 条
  • [21] CORRELATION BETWEEN DEPTH OF CURE AND TEMPERATURE RISE OF A LIGHT-ACTIVATED RESIN
    HANSEN, EK
    ASMUSSEN, E
    SCANDINAVIAN JOURNAL OF DENTAL RESEARCH, 1993, 101 (03): : 176 - 179
  • [22] TEMPERATURE RISE IN THE PULP CHAMBER DURING FABRICATION OF PROVISIONAL CROWNS
    TJAN, AHL
    GRANT, BE
    GODFREY, MF
    JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (06): : 622 - 626
  • [23] Evaluation of dental pulp temperature rise during photo-activated decontamination (PAD) of caries: an in vitro study
    Nammour, Samir
    Zeinoun, T.
    Bogaerts, I.
    Lamy, M.
    Geerts, S. O.
    Saba, S. Bou
    Lamard, L.
    Peremans, A.
    Limme, M.
    LASERS IN MEDICAL SCIENCE, 2010, 25 (05) : 651 - 654
  • [24] Evaluation of dental pulp temperature rise during photo-activated decontamination (PAD) of caries: an in vitro study
    Samir Nammour
    T. Zeinoun
    I. Bogaerts
    M. Lamy
    S. O. Geerts
    S. Bou Saba
    L. Lamard
    A. Peremans
    M. Limme
    Lasers in Medical Science, 2010, 25 : 651 - 654
  • [25] Optical Effects of Experimental Light-Activated Bleaching Procedures
    Klaric, Eva
    Rakic, Mario
    Marcius, Marijan
    Ristic, Mira
    Sever, Ivan
    Tarle, Zrinka
    PHOTOMEDICINE AND LASER SURGERY, 2014, 32 (03) : 160 - 167
  • [26] Efficacy of tooth bleaching with and without light activation and its effect on the pulp temperature: an in vitro study
    Hahn, Petra
    Schondelmaier, Nina
    Wolkewitz, Martin
    Altenburger, Markus Joerg
    Polydorou, Olga
    ODONTOLOGY, 2013, 101 (01) : 67 - 74
  • [27] Efficacy of tooth bleaching with and without light activation and its effect on the pulp temperature: an in vitro study
    Petra Hahn
    Nina Schondelmaier
    Martin Wolkewitz
    Markus Jörg Altenburger
    Olga Polydorou
    Odontology, 2013, 101 : 67 - 74
  • [28] Temperature rise in pulp chamber during fabrication of temporary crowns.
    Tjan, AHL
    Castelnuovo, J
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 2869 - 2869
  • [29] In vitro evaluation of visible light-activated titanium dioxide photocatalysis for in-office dental bleaching
    Cuppini, Marla
    Branco Leitune, Vicente Castelo
    de Souza, Marcela
    Alves, Annelise Kopp
    Werner Samuel, Susana Maria
    Collares, Fabricio Mezzomo
    DENTAL MATERIALS JOURNAL, 2019, 38 (01) : 68 - 74
  • [30] In vitro pulp chamber temperature rise from irradiation and exotherm of flowable composites
    Baroudi, Kusai
    Silikas, Nick
    Watts, David C.
    INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2009, 19 (01) : 48 - 54