Temperature rise during experimental light-activated bleaching

被引:0
|
作者
Eva Klaric
Mario Rakic
Ivan Sever
Zrinka Tarle
机构
[1] University of Zagreb,Department of Endodontics and Restorative Dentistry, School of Dental Medicine
[2] Institute of Physics,undefined
[3] Institute for Tourism,undefined
来源
Lasers in Medical Science | 2015年 / 30卷
关键词
Light; Tooth bleaching; Temperature;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to evaluate the surface and intrapulpal temperatures after treatments with different bleaching gels subjected to different types of light activation. A K-type thermocouple and infrared thermometer were used to measure the temperature increase during the 15- or 30-min treatment period. Light-emitting diode with a center wavelength of 405 nm (LED405), organic light-emitting diode (OLED), and femtosecond laser were tested and compared to ZOOM2. The tooth surface was treated with five bleaching agents and Vaseline which served as a control.The generalized estimating equation (GEE) model was applied for testing the differences in temperature increase. The ZOOM2 light source led to the largest increase in mean pulpal and tooth surface temperatures of 21.1 and 22.8 °C, followed by focused femtosecond laser which increased the pulpal and surface temperatures by up to 15.7 and 16.8 °C. Treatments with unfocused femtosecond laser, LED405, and OLED induced significantly lower mean temperature increases (p < 0.001 for each comparison with ZOOM2 and focused femtosecond laser), both in the pulp chamber (up to 2.7, 2.5, and 1.4 °C) and at the tooth surface (up to 3.2, 3.4, and 1.8 °C). Significant differences between pulp chamber and tooth surface measurements were obtained for all types of bleaching gel, during treatments with ZOOM2 (p < 0.001), LED405 (p < 0.001), and unfocused (p < 0.001) and focused femtosecond laser (p ≤ 0.002). Different bleaching agents or Vaseline can serve as an isolating layer. Focused femtosecond laser and ZOOM2 produced large temperature increases in the pulp chamber and at the tooth surface. Caution is advised when using these types of light activation, while LED405, OLED, and unfocused femtosecond laser could be safely used.
引用
收藏
页码:567 / 576
页数:9
相关论文
共 50 条
  • [1] Temperature rise during experimental light-activated bleaching
    Klaric, Eva
    Rakic, Mario
    Sever, Ivan
    Tarle, Zrinka
    [J]. LASERS IN MEDICAL SCIENCE, 2015, 30 (02) : 567 - 576
  • [2] Pulpal temperature rise during light-activated bleaching
    Eldeniz, AU
    Usumez, A
    Usumez, S
    Ozturk, N
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (02) : 254 - 259
  • [3] IN VITRO STUDY OF THE PULP CHAMBER TEMPERATURE RISE DURING LIGHT-ACTIVATED BLEACHING
    Carrasco, Thaise Graciele
    Carrasco-Guerisoli, Laise Daniela
    Froner, Izabel Cristina
    [J]. JOURNAL OF APPLIED ORAL SCIENCE, 2008, 16 (05) : 355 - 359
  • [4] Effect of light-activated bleaching on pulp chamber temperature rise: An in vitro study
    Kivanc, Bagdagul Helvacioglu
    Arisu, Hacer Deniz
    Ulusoy, Ozgur Ilke Atasoy
    Saglam, Baran Can
    Gorgul, Guliz
    [J]. AUSTRALIAN ENDODONTIC JOURNAL, 2012, 38 (02) : 76 - 79
  • [5] Temperature rise during polymerization of light-activated resin composites
    Shortall, AC
    Harrington, E
    [J]. JOURNAL OF ORAL REHABILITATION, 1998, 25 (12) : 908 - 913
  • [6] Optical Effects of Experimental Light-Activated Bleaching Procedures
    Klaric, Eva
    Rakic, Mario
    Marcius, Marijan
    Ristic, Mira
    Sever, Ivan
    Tarle, Zrinka
    [J]. PHOTOMEDICINE AND LASER SURGERY, 2014, 32 (03) : 160 - 167
  • [7] TEMPERATURE RISE DURING POLYMERIZATION OF VISIBLE LIGHT-ACTIVATED COMPOSITE RESINS
    MASUTANI, S
    SETCOS, JC
    SCHNELL, RJ
    PHILLIPS, RW
    [J]. DENTAL MATERIALS, 1988, 4 (04) : 174 - 178
  • [8] Enamel and Dentin Microhardness and Chemical Composition After Experimental Light-activated Bleaching
    Klaric, E.
    Rakic, Mario
    Sever, I.
    Milat, O.
    Par, M.
    Tarle, Z.
    [J]. OPERATIVE DENTISTRY, 2015, 40 (04) : E132 - E141
  • [9] CORRELATION BETWEEN DEPTH OF CURE AND TEMPERATURE RISE OF A LIGHT-ACTIVATED RESIN
    HANSEN, EK
    ASMUSSEN, E
    [J]. SCANDINAVIAN JOURNAL OF DENTAL RESEARCH, 1993, 101 (03): : 176 - 179
  • [10] An in vitro thermal analysis during different light-activated hydrogen peroxide bleaching
    Kabbach, W.
    Zezell, D. M.
    Bandeca, M. C.
    Pereira, T. M.
    Andrade, M. F.
    [J]. LASER PHYSICS, 2010, 20 (09) : 1833 - 1837