Temperature rise in pulp and gel during laser-activated bleaching: in vitro

被引:0
|
作者
Tugrul Sari
Gozde Celik
Aslıhan Usumez
机构
[1] Bezmialem Vakıf University Faculty of Dentistry,Department of Prosthodontics
来源
Lasers in Medical Science | 2015年 / 30卷
关键词
Temperature increase; Blood microcirculation in pulp; In-office bleaching; Er:YAG laser; Diode laser;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to evaluate the increase in temperature induced by various light sources during in-office bleaching treatment, under simulated blood microcirculation in pulp conditions. Ten freshly extracted human maxillary central incisors were used for the study. The roots of the teeth were removed from approximately 2 mm below the cementoenamel junction and fixed on an apparatus for the simulation of blood microcirculation in pulp. A J-type thermocouple wire was inserted into the pulp chamber through an artificial access at the lingual surfaces of the teeth, and another thermocouple wire was fixed on the labial surface of the teeth meanwhile. An in-office bleaching agent, intense red in color and with 30 % water content, was applied to the labial surfaces of the teeth, and repeating measurements were made for each tooth using three different light sources: Er:YAG laser (40 mJ, 10 Hz, 20 s), 810-nm diode laser (4 W, 20 s, CW), and high-intensity light-emitting diodes (LED) (1,100 mW/cm2, 20 s) as the control. Temperature increase in the pulp chamber and within the bleaching gel during light application were recorded and statistically evaluated. The highest pulp temperature increases were recorded for the diode laser group (2.61 °C), followed by the Er:YAG laser (1.86 °C) and LED (1.02 °C) groups (p < 0.05; analysis of variance (ANOVA), Tukey’s honestly significant difference (HSD)). Contradictorily, the lowest gel temperature increases were recorded for diode laser (6.21 °C) and followed by LED (12.38 °C) and Er:YAG (20.11 °C) groups (p < 0.05; ANOVA, Tukey’s HSD). Despite the significant differences among the groups, the temperature increases recorded for all groups were below the critical value of 5.6 °C that can cause irreversible harmful changes in pulp tissue. It can be concluded that, with regard to temperature increase, all the light sources evaluated in this study can be used safely for in-office bleaching treatment within the described parameters.
引用
收藏
页码:577 / 582
页数:5
相关论文
共 50 条
  • [1] Temperature rise in pulp and gel during laser-activated bleaching: in vitro
    Sari, Tugrul
    Celik, Gozde
    Usumez, Aslihan
    [J]. LASERS IN MEDICAL SCIENCE, 2015, 30 (02) : 577 - 582
  • [2] The effect of laser-activated bleaching with 445 nm and 970 nm diode lasers on pulp chamber temperature rise: an in vitro study
    Saberi, Sogol
    Shahabi, Sima
    Tohidkhah, Saba
    Jafarnia, Shiva
    Pedram, Parham
    [J]. LASER PHYSICS, 2021, 31 (05)
  • [3] IN VITRO STUDY OF THE PULP CHAMBER TEMPERATURE RISE DURING LIGHT-ACTIVATED BLEACHING
    Carrasco, Thaise Graciele
    Carrasco-Guerisoli, Laise Daniela
    Froner, Izabel Cristina
    [J]. JOURNAL OF APPLIED ORAL SCIENCE, 2008, 16 (05) : 355 - 359
  • [4] Effect of light-activated bleaching on pulp chamber temperature rise: An in vitro study
    Kivanc, Bagdagul Helvacioglu
    Arisu, Hacer Deniz
    Ulusoy, Ozgur Ilke Atasoy
    Saglam, Baran Can
    Gorgul, Guliz
    [J]. AUSTRALIAN ENDODONTIC JOURNAL, 2012, 38 (02) : 76 - 79
  • [5] Temperature rise during experimental light-activated bleaching
    Eva Klaric
    Mario Rakic
    Ivan Sever
    Zrinka Tarle
    [J]. Lasers in Medical Science, 2015, 30 : 567 - 576
  • [6] Pulpal temperature rise during light-activated bleaching
    Eldeniz, AU
    Usumez, A
    Usumez, S
    Ozturk, N
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (02) : 254 - 259
  • [7] Temperature rise during experimental light-activated bleaching
    Klaric, Eva
    Rakic, Mario
    Sever, Ivan
    Tarle, Zrinka
    [J]. LASERS IN MEDICAL SCIENCE, 2015, 30 (02) : 567 - 576
  • [8] Surface and pulp chamber temperature rises during tooth bleaching using a diode laser:: a study in vitro
    Sulieman, M.
    Rees, J. S.
    Addy, M.
    [J]. BRITISH DENTAL JOURNAL, 2006, 200 (11) : 631 - 634
  • [9] Surface and pulp chamber temperature rises during tooth bleaching using a diode laser: a study in vitro
    M Sulieman
    J S Rees
    M Addy
    [J]. British Dental Journal, 2006, 200 : 631 - 634
  • [10] The Effectiveness of Low-Intensity Red Laser for Activating a Bleaching Gel and Its Effect in Temperature of the Bleaching Gel and the Dental Pulp
    Kugel, Gerard
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2012, 24 (02) : 133 - 134