STATOR TURN-TO-TURN FAULT DETECTION OF SYNCHRONOUS GENERATOR USING TOTAL HARMONIC DISTORTION (THD) ANALYZING OF MAGNETIC FLUX LINKAGE

被引:0
|
作者
Yaghobi, H. [1 ]
Ansari, K. [2 ]
Mashhadi, H. Rajabi [2 ]
机构
[1] Semnan Univ, Dept Elect Engn, Semnan, Iran
[2] Ferdowsi Univ Mashhad, Dept Elect Engn, Mashhad, Iran
关键词
Synchronous generator; inter-turn fault; magnetic flux linkage; harmonic analysis; ELECTRICAL MACHINES; INTERNAL FAULTS; DIAGNOSIS; MOTORS; LOAD; MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Diagnostics of synchronous generator turn-to-turn faults can be accomplished by analyzing the anomalies of machine local variable such as magnetic flux linkage. On the other hand, because current transformers and voltage transformers are usually installed in the machine for different purposes as default, the monitoring schemes that depend on the study of these inputs have become a topic of interest. As a consequence, in the last two decades, a variety of methods have been proposed based only on the global external variable (such as stator current and voltage). It must be noted that the global external variable analysis techniques are not capable of detecting all of the potential faults in electrical machines and some researches, including this work, aim to transfer a part of the global external variables analysis knowledge to techniques that monitor the signatures produced by the fault to the electromagnetic flux signals (local variable). Hence, this contribution deals with the analysis of the stator turn-to-turn short circuit fault of salient-pole synchronous generator. In this paper, a fault indicator based on harmonic analysis of the magnetic flux linkage is investigated. Experimental results derived from a 4-pole, 380V, 1500 rpm, 50 Hz, 50 KVA, 3-phase salient-pole synchronous generator, show that the proposed method is useful and effective.
引用
收藏
页码:161 / 182
页数:22
相关论文
共 50 条
  • [21] Feasibility Analysis of Fault-tolerant Technology for Stator Winding Turn-to-turn Short-circuit Fault of Offshore Doubly-fed Induction Generator
    Wei S.
    Wu R.
    Fu Y.
    Zhang K.
    Zhang Z.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (05): : 114 - 120and128
  • [22] Stator Inter-Turn Fault Detection of BLDC Motor using Third Harmonic According to Asymmetric Magnetic Fields
    Lee, S.
    Hur, J.
    2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,
  • [23] Turn to Turn Fault Detection and Classification in Stator Winding of Synchronous Generators Based on Terminal Voltage Waveform Components
    Fayazi, Mohammad
    Haghjoo, Farhad
    9TH POWER SYSTEMS PROTECTION AND CONTROL CONFERENCE (PSPC2015), 2015, : 36 - 41
  • [24] Turn-to-Turn Fault Diagnosis on Three-Phase Power Transformer Using Hybrid Detection Algorithm
    Liu, Chien-Hsun
    Muda, Willybrordus H. P.
    Kuo, Cheng-Chien
    APPLIED SCIENCES-BASEL, 2021, 11 (06):
  • [25] Stator Inter-turn Fault Detection of Synchronous Machines Using Field Current Signature Analysis
    Neti, Prabhakar
    Nandi, Subhasis
    CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 2360 - 2367
  • [26] Calculation of Distributed Magnetic Flux Density under the Stator-Turn Fault Condition
    Kim, Kyung-Tae
    Hur, Jin
    Kim, Byeong-Woo
    JOURNAL OF POWER ELECTRONICS, 2013, 13 (04) : 552 - 557
  • [27] Analysis of primary side turn-to-turn short circuit fault in PT at the generator outlet and diagnosis using CSSA-GMM
    Wei, Yang
    Li, Chen
    Ai, Yuangao
    Shen, Hongwan
    Zeng, Shai
    Sun, Yue
    Frontiers in Energy Research, 2024, 12
  • [28] Online Model-Based Condition Monitoring for Brushless Wound-Field Synchronous Generator to Detect and Diagnose Stator Windings Turn-to-Turn Shorts Using Extended Kalman Filter
    Nadarajan, Sivakumar
    Panda, Sanjib Kumar
    Bhangu, Bicky
    Gupta, Amit Kumar
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (05) : 3228 - 3241
  • [29] Research on characteristic law of synchronous generator with stator winding inter-turn short circuit fault
    Xin P.
    Ge B.-J.
    Tao D.-J.
    Zhao H.-S.
    Xiao S.-Y.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2019, 23 (01): : 45 - 51
  • [30] Detection for Stator Winding Turn Fault by using Fuzzy Neural Network
    Wang Xu-hong
    He Yi-gang
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, PTS 1 AND 2, 2011, 48-49 : 415 - +