Research on characteristic law of synchronous generator with stator winding inter-turn short circuit fault

被引:0
|
作者
Xin P. [1 ,2 ]
Ge B.-J. [1 ]
Tao D.-J. [1 ]
Zhao H.-S. [1 ]
Xiao S.-Y. [1 ]
机构
[1] School of Electrical and Electronic Engineering, Harbin University of Science and Technology, Harbin
[2] College of Information and Control Engineering, Jilin Institute of Chemical Technology, Jilin
关键词
Field-circuit-network coupling; Inter-turn short circuit; Stator winding; Synchronous generator;
D O I
10.15938/j.emc.2019.01.006
中图分类号
学科分类号
摘要
In order to truly and effectively reflect the stator current and harmonic electromagnetic torque variation laws of grid connected synchronous generator with stator winding inter-turn short circuit fault, the field-circuit-network coupling finite element method was adopted to analyze this problem in detail. Taking a 1 407 MVA nuclear power half speed turbine generator as an example, the model of field-circuit-network coupling is established, when the grid-connected generator runs at rated load and stable state. Then, the stator winding inter-turn short circuit fault of generator is simulated in same fault degree and different fault position. The influences of generator stator winding inter-turn short circuit fault position on three-phase current, transient fundamental electromagnetic torque, transient two harmonic electromagnetic torque and steady state two harmonic electromagnetic torque of generator are all studied. The stator winding inter-turn short circuit fault diagnosis in big synchronous generator is provided by the research. © 2019, Harbin University of Science and Technology Publication. All right reserved.
引用
收藏
页码:45 / 51
页数:6
相关论文
共 19 条
  • [1] Prasad B.J.C., Sanker R.B.V., Inter-turn fault analysis of synchronous generator using finite element method (FEM), International Journal of Recent Technology and Engineering, 2, 5, (2013)
  • [2] Gandhi A., Corrigan T., Parsa L., Recent advances in modeling and online detection of stator interturn faults in electrical motors, IEEE Transactions on Industrial Electronics, 58, 5, (2011)
  • [3] Reichmeider P.P., Querrey D., Gross C.A., Et al., Partitioning of synchronous machine windings for internal fault analysis, IEEE Transactions on Energy Conversion, 15, 4, (2000)
  • [4] Tang G., He Y., Wan S., Et al., Effect of static eccentricity & stator short circuit composite faults on stator vibration characteristics of generator, Journal of Vibration Engineering, 27, 1, (2014)
  • [5] Megahed A.I., Malik O.P., Synchronous generator internal fault computation and experimental verification, IEEE Proceedings-Generation Transmission and Distribution, 145, 5, (1998)
  • [6] He Y., Wang F., Tang G., Et al., Effect of stator inter-Turn short circuit position on electromagnetic torque of generator with consideration of air-gap eccentricity, Transactions of China Electrotechnical Society, 32, 7, (2017)
  • [7] Zhao H., Ge B., Tao D., Et al., Influence of stator winding inter turn short circuit fault on generator electromagnetic torque characteristics, Transactions of China Electrotechnical Society, 31, 5, (2016)
  • [8] Wan S., Li H., Xu Z., Et al., Analysis of generator vibration characteristic on stator winding inter-turn short circuit fault, Proceedings of the CSEE, 24, 4, (2004)
  • [9] Fang H., Xia C., Xiu J., Analysis of generator electro-magnetic torque on armature winding inter-turn short circuit fault, Proceedings of the CSEE, 27, 15, (2007)
  • [10] Sarikhani A., Mohammed O.A., Inter-turn fault detection in PM synchronous machines by physics-based back electromotive force estimation, IEEE Transactions on Industrial Electronics, 60, 8, (2013)