STATOR TURN-TO-TURN FAULT DETECTION OF SYNCHRONOUS GENERATOR USING TOTAL HARMONIC DISTORTION (THD) ANALYZING OF MAGNETIC FLUX LINKAGE

被引:0
|
作者
Yaghobi, H. [1 ]
Ansari, K. [2 ]
Mashhadi, H. Rajabi [2 ]
机构
[1] Semnan Univ, Dept Elect Engn, Semnan, Iran
[2] Ferdowsi Univ Mashhad, Dept Elect Engn, Mashhad, Iran
关键词
Synchronous generator; inter-turn fault; magnetic flux linkage; harmonic analysis; ELECTRICAL MACHINES; INTERNAL FAULTS; DIAGNOSIS; MOTORS; LOAD; MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Diagnostics of synchronous generator turn-to-turn faults can be accomplished by analyzing the anomalies of machine local variable such as magnetic flux linkage. On the other hand, because current transformers and voltage transformers are usually installed in the machine for different purposes as default, the monitoring schemes that depend on the study of these inputs have become a topic of interest. As a consequence, in the last two decades, a variety of methods have been proposed based only on the global external variable (such as stator current and voltage). It must be noted that the global external variable analysis techniques are not capable of detecting all of the potential faults in electrical machines and some researches, including this work, aim to transfer a part of the global external variables analysis knowledge to techniques that monitor the signatures produced by the fault to the electromagnetic flux signals (local variable). Hence, this contribution deals with the analysis of the stator turn-to-turn short circuit fault of salient-pole synchronous generator. In this paper, a fault indicator based on harmonic analysis of the magnetic flux linkage is investigated. Experimental results derived from a 4-pole, 380V, 1500 rpm, 50 Hz, 50 KVA, 3-phase salient-pole synchronous generator, show that the proposed method is useful and effective.
引用
收藏
页码:161 / 182
页数:22
相关论文
共 50 条
  • [41] Stator End-Winding Thermal and Magnetic Sensor Arrays for Online Stator Inter-Turn Fault Detection
    Kumar, Padmanabhan Sampath
    Xie, Lihua
    Halick, Mohamed Sathik Mohamed
    Vaiyapuri, Viswanathan
    IEEE SENSORS JOURNAL, 2021, 21 (04) : 5312 - 5321
  • [42] Modeling and detecting the stator winding inter turn fault of permanent magnet synchronous motors using stator current signature analysis
    Yassa, N.
    Rachek, M.
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2020, 167 : 325 - 339
  • [43] Stator Turn Fault Detection by Second Harmonic in Instantaneous Power for a Triple-Redundant Fault-Tolerant PM Drive
    Wang, Bo
    Wang, Jiabin
    Griffo, Antonio
    Sen, Bhaskar
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (09) : 7279 - 7289
  • [44] Detection of stator turn fault in induction motors using the extension of multiple reference frames theory
    Liu, T
    Chen, HH
    IECON 2005: THIRTY-FIRST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, 2005, : 1752 - 1755
  • [45] Detection and Analysis of Stator Winding Inter-Turn Short Circuit Fault in Permanent Magnet Linear Synchronous Motor
    Gao, Caixia
    Hao, Chen
    Zhao, Yuebing
    OPTICAL, ELECTRONIC MATERIALS AND APPLICATIONS II, 2012, 529 : 322 - +
  • [46] Back-EMF based detection of stator winding inter-turn fault for PM synchronous motor drives
    Boileau, T.
    Nahid-Mobarakeh, B.
    Meibody-Tabar, F.
    2007 IEEE VEHICLE POWER AND PROPULSION CONFERENCE, VOLS 1 AND 2, 2007, : 95 - 100
  • [47] Detection of the Stator Winding Inter-Turn Faults in Asynchronous and Synchronous Machines Through the Correlation Between Harmonics of the Voltage of Two Magnetic Flux Sensors
    Irhoumah, Miftah
    Pusca, Remus
    Lefevre, Eric
    Mercier, David
    Romary, Raphael
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (03) : 2682 - 2689
  • [48] Inter-turn fault diagnosis of permanent magnet synchronous machine based on tooth magnetic flux analysis
    Zeng, Chong
    Huang, Song
    Yang, Yongming
    Wu, Dun
    IET ELECTRIC POWER APPLICATIONS, 2018, 12 (06) : 837 - 844
  • [49] Investigation of turbine generator rotor winding inter-turn short circuit fault based on harmonic detection
    Wu Yucai
    Li Yonggang
    Wan Shuting
    Li Heming
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 829 - 833
  • [50] The Initial Temperature Rise in a Permanent Magnet Synchronous Generator as a Tool in the Detection of Stator Inter-Turn Short-Circuits
    Barrett, Michael
    2020 INTERNATIONAL SYMPOSIUM ON FUNDAMENTALS OF ELECTRICAL ENGINEERING (ISFEE), 2020,