STATOR TURN-TO-TURN FAULT DETECTION OF SYNCHRONOUS GENERATOR USING TOTAL HARMONIC DISTORTION (THD) ANALYZING OF MAGNETIC FLUX LINKAGE

被引:0
|
作者
Yaghobi, H. [1 ]
Ansari, K. [2 ]
Mashhadi, H. Rajabi [2 ]
机构
[1] Semnan Univ, Dept Elect Engn, Semnan, Iran
[2] Ferdowsi Univ Mashhad, Dept Elect Engn, Mashhad, Iran
关键词
Synchronous generator; inter-turn fault; magnetic flux linkage; harmonic analysis; ELECTRICAL MACHINES; INTERNAL FAULTS; DIAGNOSIS; MOTORS; LOAD; MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Diagnostics of synchronous generator turn-to-turn faults can be accomplished by analyzing the anomalies of machine local variable such as magnetic flux linkage. On the other hand, because current transformers and voltage transformers are usually installed in the machine for different purposes as default, the monitoring schemes that depend on the study of these inputs have become a topic of interest. As a consequence, in the last two decades, a variety of methods have been proposed based only on the global external variable (such as stator current and voltage). It must be noted that the global external variable analysis techniques are not capable of detecting all of the potential faults in electrical machines and some researches, including this work, aim to transfer a part of the global external variables analysis knowledge to techniques that monitor the signatures produced by the fault to the electromagnetic flux signals (local variable). Hence, this contribution deals with the analysis of the stator turn-to-turn short circuit fault of salient-pole synchronous generator. In this paper, a fault indicator based on harmonic analysis of the magnetic flux linkage is investigated. Experimental results derived from a 4-pole, 380V, 1500 rpm, 50 Hz, 50 KVA, 3-phase salient-pole synchronous generator, show that the proposed method is useful and effective.
引用
收藏
页码:161 / 182
页数:22
相关论文
共 50 条
  • [1] Brushless Synchronous Generator Turn-to-Turn Short Circuit Fault Detection Using Multilayer Neural Network
    Tun, Pyae Phyo
    Kumar, Padmanabhan Sampath
    Pratama, Ryan Arya
    Liu Shuyong
    2018 ASIAN CONFERENCE ON ENERGY, POWER AND TRANSPORTATION ELECTRIFICATION (ACEPT), 2018,
  • [2] Power Losses and Magnetic Flux Analysis of Vector Controlled Induction Motor with Stator Turn-to-Turn Fault
    Eldeeb, Hassan H.
    Zhao, Haisen
    Mohammed, Osama A.
    2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 724 - 728
  • [3] Detection of Turn-to-Turn Faults in the Stator and Rotor of Synchronous Machines During Startup
    Afrandideh, Saeed
    Haghjoo, Farhad
    Cruz, Sergio
    Milasi, Mostafa Eshaghi
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (08) : 7485 - 7495
  • [4] Modeling and harmonic analysis of a permanent magnet synchronous machine with turn-to-turn fault
    Harsjo, Joachim
    Bongiorno, Massimo
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [5] Stator and rotor turn-to-turn fault detection in wound rotor induction machines based on the air-gap magnetic field distortion
    Nazemi, Mohammad Hosein
    Haghjoo, Farhad
    Cruz, Sergio Manuel A.
    Gallehdar, Davar
    IET ELECTRIC POWER APPLICATIONS, 2020, 14 (13) : 2631 - 2639
  • [6] Leakage Flux based turn-to-turn Fault Detection for Shunt Inductor
    Chen, R.
    Dong, J.
    Tian, C.
    Chen, Q.
    2018 IEEE INTERNATIONAL MAGNETIC CONFERENCE (INTERMAG), 2018,
  • [7] Improved Brushless Synchronous Generator Model to Study the Turn-to-Turn Short Circuit Fault
    Sivakumar, Nadarajan
    Bhangu, Bicky
    Panda, S. K.
    Gupta, Amit Kumar
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [8] Hybrid Model for Wound-Rotor Synchronous Generator to Detect and Diagnose Turn-to-Turn Short-Circuit Fault in Stator Windings
    Nadarajan, Sivakumar
    Panda, S. K.
    Bhangu, Bicky
    Gupta, Amit Kumar
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (03) : 1888 - 1900
  • [9] Dynamic Model of Brushless Synchronous Generator with Turn-to-Turn Short Circuit Fault for Condition Monitoring
    Sivakumar, Nadarajan
    Panda, S. K.
    Bhangu, Bicky
    Gupta, Amit Kumar
    2013 IEEE ECCE ASIA DOWNUNDER (ECCE ASIA), 2013, : 258 - 263
  • [10] Fault Diagnosis of Stator Winding Turn to Turn Short Circuit of Synchronous Rectifier Generator
    Zhang, Jingnan
    Wu, Liqin
    Zhang, Tianhao
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 2001 - 2005