Fracture Strength of Zirconia Implants after Artificial Aging

被引:105
|
作者
Andreiotelli, Marina [1 ]
Kohal, Ralf-Joachim [1 ]
机构
[1] Univ Freiburg, Dept Prosthodont, Sch Dent, D-79106 Freiburg, Germany
关键词
artificial mouth; fracture strength; titanium implants; zirconia implants; FLEXURAL STRENGTH; CERAMIC MATERIALS; DENTAL CERAMICS; CLINICAL REPORT; ONE-PIECE; SURFACE; TRANSFORMATION; PROSTHESES; SYSTEM; COMPLICATIONS;
D O I
10.1111/j.1708-8208.2008.00105.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Zirconia (ZrO2) might be an alternative material to titanium (Ti) for dental implant fabrication. However, no data are available on the fracture strength of one-piece ZrO2 oral implants. The objective of this study was to evaluate the fracture strength of ZrO2 implants after exposure to the artificial mouth. One hundred twenty ZrO2 and Ti implants were used. The Ti implants were divided into two control groups (A and B). ZrO2 implants manufactured from yttria-stabilized tetragonal ZrO2 polycrystal (Y-TZP) in group C, from Y-TZP dotted with alumina (Y-TZP-A) in group D, and from Y-TZP-A with a modified surface in groups E and F were used. In group F, the implant heads were prepared, and in group G, the implants were restored with ZrO2 crowns. Each group included 16 samples with the exception of group D, which included 24 samples. A subgroup of each implant type (eight implants) was subjected to thermomechanical cycling in a chewing simulator prior to fracture testing. Test specimens were then loaded until a fracture occurred. Seven of the 120 samples failed in the chewing simulator. ZrO2 implant fracture occurred at 725 to 850 N when the implants were not prepared, and at 539 to 607 N when prepared. The samples in group A fractured at the level of the abutment screw. All ZrO2 implants fractured at the level of the Technovit (R) resin (Heraeus Kulzer GmbH & Co., Wehrheim, Germany). No fracture of the ZrO2 crowns in group G was observed. Mean fracture strength values obtained were all within the limits of clinical acceptance. However, implant preparation had a statistically significant negative influence on the implant fracture strength. Long-term clinical data are necessary before one-piece ZrO2 implants can be recommended for daily practice.
引用
收藏
页码:158 / 166
页数:9
相关论文
共 50 条
  • [1] Influence of the yttrium content on the fracture strength of monolithic zirconia crowns after artificial aging
    Elsayed, Adham
    Meyer, Gunnar
    Wille, Sebastian
    Kern, Matthias
    QUINTESSENCE INTERNATIONAL, 2019, 50 (05): : 344 - 348
  • [2] Analysis of Stress and Fracture Strength of Zirconia Implants after Cyclic Loading
    Cruvinel, Diogo Rodrigues
    Silveira, Renata Espindola
    Galo, Rodrigo
    Alandia-Roman, Carla Cecilia
    Panzeri Pires-de-Souza, Fernanda de Carvalho
    Panzeri, Heitor
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2015, 18 (05): : 1082 - 1088
  • [3] SOLUBILITY AND STRENGTH OF ZIRCONIA-BASED DENTAL MATERIALS AFTER ARTIFICIAL AGING
    Kvam, Ketil
    Karlsson, Stig
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (04): : 281 - 287
  • [4] Fracture Strength of Zirconia and Alumina Ceramic Crowns Supported by Implants
    Traini, Tonino
    Sorrentino, Roberto
    Gherlone, Enrico
    Perfetti, Federico
    Bollero, Patrizio
    Zarone, Ferdinando
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 : 352 - 359
  • [5] Influence of shading on zirconia's phase transformation and flexural strength after artificial aging
    Wille, Sebastian
    Moeller, Rudiger
    Kern, Matthias
    DENTAL MATERIALS, 2023, 39 (08) : 702 - 707
  • [6] Fracture strength of screw-retained zirconia crowns assembled on zirconia and titanium implants
    Sadid-Zadeh, Ramtin
    Lin, Kevin
    Li, Rui
    Nagy, Katalin
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (03): : 273 - 280
  • [7] Translucency of Zirconia Ceramics before and after Artificial Aging
    Walczak, Katarzyna
    Meissner, Heike
    Range, Ursula
    Sakkas, Andreas
    Boening, Klaus
    Wieckiewicz, Mieszko
    Konstantinidis, Ioannis
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (01): : E319 - E324
  • [8] Stability of Prototype Two-Piece Zirconia and Titanium Implants after Artificial Aging: An In Vitro Pilot Study
    Kohal, Ralf-Joachim
    Finke, Hans Christian
    Klaus, Gerold
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (04) : 323 - 329
  • [9] Fracture resistance of zirconia-based implant abutments after artificial long-term aging
    Alsahhaf, Abdulaziz
    Spies, Benedikt Christopher
    Vach, Kirstin
    Kohal, Ralf-Joachim
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 66 : 224 - 232
  • [10] Effects of dynamic aging on the wear and fracture strength of monolithic zirconia restorations
    Işıl Sarıkaya
    Yeliz Hayran
    BMC Oral Health, 18