Fracture Strength of Zirconia Implants after Artificial Aging

被引:105
|
作者
Andreiotelli, Marina [1 ]
Kohal, Ralf-Joachim [1 ]
机构
[1] Univ Freiburg, Dept Prosthodont, Sch Dent, D-79106 Freiburg, Germany
关键词
artificial mouth; fracture strength; titanium implants; zirconia implants; FLEXURAL STRENGTH; CERAMIC MATERIALS; DENTAL CERAMICS; CLINICAL REPORT; ONE-PIECE; SURFACE; TRANSFORMATION; PROSTHESES; SYSTEM; COMPLICATIONS;
D O I
10.1111/j.1708-8208.2008.00105.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Zirconia (ZrO2) might be an alternative material to titanium (Ti) for dental implant fabrication. However, no data are available on the fracture strength of one-piece ZrO2 oral implants. The objective of this study was to evaluate the fracture strength of ZrO2 implants after exposure to the artificial mouth. One hundred twenty ZrO2 and Ti implants were used. The Ti implants were divided into two control groups (A and B). ZrO2 implants manufactured from yttria-stabilized tetragonal ZrO2 polycrystal (Y-TZP) in group C, from Y-TZP dotted with alumina (Y-TZP-A) in group D, and from Y-TZP-A with a modified surface in groups E and F were used. In group F, the implant heads were prepared, and in group G, the implants were restored with ZrO2 crowns. Each group included 16 samples with the exception of group D, which included 24 samples. A subgroup of each implant type (eight implants) was subjected to thermomechanical cycling in a chewing simulator prior to fracture testing. Test specimens were then loaded until a fracture occurred. Seven of the 120 samples failed in the chewing simulator. ZrO2 implant fracture occurred at 725 to 850 N when the implants were not prepared, and at 539 to 607 N when prepared. The samples in group A fractured at the level of the abutment screw. All ZrO2 implants fractured at the level of the Technovit (R) resin (Heraeus Kulzer GmbH & Co., Wehrheim, Germany). No fracture of the ZrO2 crowns in group G was observed. Mean fracture strength values obtained were all within the limits of clinical acceptance. However, implant preparation had a statistically significant negative influence on the implant fracture strength. Long-term clinical data are necessary before one-piece ZrO2 implants can be recommended for daily practice.
引用
收藏
页码:158 / 166
页数:9
相关论文
共 50 条
  • [21] Fracture Strength After Fatigue Loading of Lithium Disilicate Pressed Zirconia Crowns
    Kim, So-Yeun
    Choi, Jae-Won
    Ju, Sung-Won
    Ahn, Jin-Soo
    Yoon, Mi-Jung
    Huh, Jung-Bo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (04) : 369 - 371
  • [22] Influence of loading and aging on the fracture strength of an injection-molded two-piece zirconia implant restored with a zirconia abutment
    Kohal, Ralf-Joachim
    von Schierholz, Christopher
    Nold, Julian
    Spies, Benedikt C. C.
    Adolfsson, Erik
    Vach, Kirstin
    Burkhardt, Felix
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (02) : 105 - 115
  • [23] Influence of Different CAD/CAM Crown Materials on the Fracture of Custom-Made Titanium and Zirconia Implant Abutments After Artificial Aging
    Elsayed, Adham
    Farrag, Gasser
    Chaar, Mohamed Sad
    Abdelnabi, Nouran
    Kern, Matthias
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (01) : 91 - 96
  • [24] Fatigue resistance and fracture strength of narrow-diameter one-piece zirconia implants with angled abutments
    Atalay, Pelin
    Oztas, Dogan Derya
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (07) : 1060 - 1067
  • [25] Strength and fracture toughness of zirconia dental ceramics
    Turon-Vinas, Miquel
    Anglada, Marc
    DENTAL MATERIALS, 2018, 34 (03) : 365 - 375
  • [26] Influence of Fabrication Techniques and Artificial Aging on the Fracture Resistance of Different Cantilever Zirconia Fixed Dental Prostheses
    Ghazy, Mohamed H.
    Madina, Manal M. Abo
    Aboushelib, Moustafa N.
    JOURNAL OF ADHESIVE DENTISTRY, 2012, 14 (02): : 161 - 166
  • [27] Influence of artificial aging on the fracture strength and stiffness of targis/vectris fixed partial dentures
    Baldissara, Paolo
    Parisi, Candida
    Monaco, Carlo
    Scotti, Roberto
    QUINTESSENCE INTERNATIONAL, 2007, 38 (02): : 153 - 159
  • [28] Flexural Strength of Modern CAD/CAM Restoratives After Artificial Aging
    Melc, Thomas
    Attin, Thomas
    Eyuboglu, Tan Firat
    Ozcan, Mutlu
    MATERIALS, 2024, 17 (21)
  • [29] Fracture Resistance of Monolithic High-Translucency Crowns Versus Porcelain-Veneered Zirconia Crowns After Artificial Aging: An In Vitro Study
    Ezzat, Yousef
    Sharka, Rayan
    Rayyan, Mohammad
    Al-Rafee, Mohammed
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (12)
  • [30] FRACTURE STRENGTH AND MICROSTRUCTURE OF Y-TZP ZIRCONIA AFTER DIFFERENT SURFACE TREATMENTS
    Song, Jin-Young
    Park, Sang-Won
    Lee, Kwangmin
    Yun, Kwi-Dug
    Lim, Hyun-Pil
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (04): : 274 - 280