Fracture Strength of Zirconia Implants after Artificial Aging

被引:105
|
作者
Andreiotelli, Marina [1 ]
Kohal, Ralf-Joachim [1 ]
机构
[1] Univ Freiburg, Dept Prosthodont, Sch Dent, D-79106 Freiburg, Germany
关键词
artificial mouth; fracture strength; titanium implants; zirconia implants; FLEXURAL STRENGTH; CERAMIC MATERIALS; DENTAL CERAMICS; CLINICAL REPORT; ONE-PIECE; SURFACE; TRANSFORMATION; PROSTHESES; SYSTEM; COMPLICATIONS;
D O I
10.1111/j.1708-8208.2008.00105.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Zirconia (ZrO2) might be an alternative material to titanium (Ti) for dental implant fabrication. However, no data are available on the fracture strength of one-piece ZrO2 oral implants. The objective of this study was to evaluate the fracture strength of ZrO2 implants after exposure to the artificial mouth. One hundred twenty ZrO2 and Ti implants were used. The Ti implants were divided into two control groups (A and B). ZrO2 implants manufactured from yttria-stabilized tetragonal ZrO2 polycrystal (Y-TZP) in group C, from Y-TZP dotted with alumina (Y-TZP-A) in group D, and from Y-TZP-A with a modified surface in groups E and F were used. In group F, the implant heads were prepared, and in group G, the implants were restored with ZrO2 crowns. Each group included 16 samples with the exception of group D, which included 24 samples. A subgroup of each implant type (eight implants) was subjected to thermomechanical cycling in a chewing simulator prior to fracture testing. Test specimens were then loaded until a fracture occurred. Seven of the 120 samples failed in the chewing simulator. ZrO2 implant fracture occurred at 725 to 850 N when the implants were not prepared, and at 539 to 607 N when prepared. The samples in group A fractured at the level of the abutment screw. All ZrO2 implants fractured at the level of the Technovit (R) resin (Heraeus Kulzer GmbH & Co., Wehrheim, Germany). No fracture of the ZrO2 crowns in group G was observed. Mean fracture strength values obtained were all within the limits of clinical acceptance. However, implant preparation had a statistically significant negative influence on the implant fracture strength. Long-term clinical data are necessary before one-piece ZrO2 implants can be recommended for daily practice.
引用
收藏
页码:158 / 166
页数:9
相关论文
共 50 条
  • [31] Fracture Resistance Behaviors of Titanium-Zirconium and Zirconia Implants
    Hanes, Brenda
    Feitosa, Sabrina
    Phasuk, Kamolphob
    Levon, John A.
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 441 - 446
  • [32] Phase transformation of dental zirconia following artificial aging
    Lucas, Thomas J.
    Lawson, Nathaniel C.
    Janowski, Gregg M.
    Burgess, John O.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2015, 103 (07) : 1519 - 1523
  • [33] In vitro comparison of fracture load of implant-supported, zirconia-based, porcelain- and composite-layered restorations after artificial aging
    Komine, Futoshi
    Taguchi, Kohei
    Fushiki, Ryosuke
    Kamio, Shingo
    Iwasaki, Taro
    Matsumura, Hideo
    DENTAL MATERIALS JOURNAL, 2014, 33 (05) : 607 - 613
  • [34] Fracture toughness and flexural strength of Duceram LFC after aging in water.
    Scherrer, SS
    Denry, IL
    Wiskott, HWA
    Belser, UC
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 248 - 248
  • [35] Fracture Strength of Direct and Indirect Composite Veneers After Aging: An In Vitro Study
    Menon, Aishwarya
    Kumar, Sowmya M.
    Hegde, Chethan
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2023, 15 (05): : 469 - 475
  • [36] Evaluation of Mechanical Strength, Translucency, and Microstructure in Graded Zirconia Layers Before and After Hydrothermal Aging
    Soares, Pablo Machado
    Souza, Luiza Freitas Brum
    da Rosa, Lucas Saldanha
    Valandro, Luiz Felipe
    Dorneles, Lucio Strazzabosco
    Holkem, Alice Penteado
    Mello, Paola de Azevedo
    Muller, Edson Irineu
    Bacchi, Atais
    Pereira, Gabriel Kalil Rocha
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2025, 113 (03)
  • [37] Zirconia layers: Structure, residual stress and fracture strength
    Djuidje-Dzumgam, Josiane
    Berdin, Clotilde
    Andrieux, Michel
    Ribot, Patrick
    ENGINEERING FRACTURE MECHANICS, 2019, 214 : 378 - 389
  • [38] Zirconia bond strength durability following artificial aging: A systematic review and meta-analysis of in vitro studies
    Rigos, Athanasios E.
    Sarafidou, Katia
    Kontonasaki, Eleana
    JAPANESE DENTAL SCIENCE REVIEW, 2023, 59 : 138 - 159
  • [39] Hydrothermal Ageing and Its Effect on Fracture Load of Zirconia Dental Implants
    Gremillard, Laurent
    Mattlet, Agnes
    Mathevon, Alexandre
    Fabregue, Damien
    Zberg, Bruno
    Stephan, Marc
    MATERIALS, 2021, 14 (11)
  • [40] Fracture toughness, work of fracture, flexural strength and elastic modulus of 3D-printed denture base resins in two measurement environments after artificial aging
    Geiger, Veronika
    Mayinger, Felicitas
    Hoffmann, Moritz
    Reymus, Marcel
    Stawarczyk, Bogna
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 150