Fracture Strength of Zirconia Implants after Artificial Aging

被引:105
|
作者
Andreiotelli, Marina [1 ]
Kohal, Ralf-Joachim [1 ]
机构
[1] Univ Freiburg, Dept Prosthodont, Sch Dent, D-79106 Freiburg, Germany
关键词
artificial mouth; fracture strength; titanium implants; zirconia implants; FLEXURAL STRENGTH; CERAMIC MATERIALS; DENTAL CERAMICS; CLINICAL REPORT; ONE-PIECE; SURFACE; TRANSFORMATION; PROSTHESES; SYSTEM; COMPLICATIONS;
D O I
10.1111/j.1708-8208.2008.00105.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Zirconia (ZrO2) might be an alternative material to titanium (Ti) for dental implant fabrication. However, no data are available on the fracture strength of one-piece ZrO2 oral implants. The objective of this study was to evaluate the fracture strength of ZrO2 implants after exposure to the artificial mouth. One hundred twenty ZrO2 and Ti implants were used. The Ti implants were divided into two control groups (A and B). ZrO2 implants manufactured from yttria-stabilized tetragonal ZrO2 polycrystal (Y-TZP) in group C, from Y-TZP dotted with alumina (Y-TZP-A) in group D, and from Y-TZP-A with a modified surface in groups E and F were used. In group F, the implant heads were prepared, and in group G, the implants were restored with ZrO2 crowns. Each group included 16 samples with the exception of group D, which included 24 samples. A subgroup of each implant type (eight implants) was subjected to thermomechanical cycling in a chewing simulator prior to fracture testing. Test specimens were then loaded until a fracture occurred. Seven of the 120 samples failed in the chewing simulator. ZrO2 implant fracture occurred at 725 to 850 N when the implants were not prepared, and at 539 to 607 N when prepared. The samples in group A fractured at the level of the abutment screw. All ZrO2 implants fractured at the level of the Technovit (R) resin (Heraeus Kulzer GmbH & Co., Wehrheim, Germany). No fracture of the ZrO2 crowns in group G was observed. Mean fracture strength values obtained were all within the limits of clinical acceptance. However, implant preparation had a statistically significant negative influence on the implant fracture strength. Long-term clinical data are necessary before one-piece ZrO2 implants can be recommended for daily practice.
引用
收藏
页码:158 / 166
页数:9
相关论文
共 50 条
  • [41] All-Ceramic Single Crown Restauration of Zirconia Oral Implants and Its Influence on Fracture Resistance: An Investigation in the Artificial Mouth
    Kohal, Ralf-Joachim
    Kilian, Jolanta Bernadette
    Stampf, Susanne
    Spies, Benedikt Christopher
    MATERIALS, 2015, 8 (04): : 1577 - 1589
  • [42] Fracture Load and Fracture Patterns of Monolithic Three-Unit Anterior Fixed Dental Prostheses after In Vitro Artificial Aging-A Comparison between Color-Gradient and Strength-Gradient Multilayer Zirconia Materials with Varying Yttria Content
    Poeppel, Max L.
    Rosentritt, Martin
    Sturm, Richard
    Beuer, Florian
    Hey, Jeremias
    Schmid, Alois
    Schmidt, Franziska
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (17)
  • [43] Translucency and mechanical behavior of  partially stabilized monolithic zirconia after staining, finishing procedures and artificial aging
    Allan Oliveira da Silva
    Lívia Fiorin
    Adriana Claudia Lapria Faria
    Ricardo Faria Ribeiro
    Renata Cristina Silveira Rodrigues
    Scientific Reports, 12
  • [44] The mechanical behavior of high-translucent monolithic zirconia after adjustment and finishing procedures and artificial aging
    Hatanaka, Gabriel Rodrigues
    Polli, Gabriela Scatimburgo
    Adabo, Gelson Luis
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (02): : 330 - 337
  • [45] Translucency and mechanical behavior of partially stabilized monolithic zirconia after staining, finishing procedures and artificial aging
    da Silva, Allan Oliveira
    Fiorin, Livia
    Lapria Faria, Adriana Claudia
    Ribeiro, Ricardo Faria
    Silveira Rodrigues, Renata Cristina
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [46] Bond Strength between Different Zirconia-Based Ceramics and Resin Cement before and after Aging
    Motta Silveira, Marcos Paulo
    Ramos, Nathalia de Carvalho
    Scalzer Lopes, Guilherme da Rocha
    Mendes Tribst, Joao Paulo
    Bottino, Marco Antonio
    COATINGS, 2022, 12 (10)
  • [47] Fracture strength of implant- supported monolithic crowns after aging in a mastication simulator
    Salvarli, Kaan Cevat
    Cevlik, Esra Talay
    INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2023, 18 (01): : 38 - 48
  • [48] Tensile Strength Differences and Type Of Fracture In Artificial Aging Process Of Duralium Against Cooling Media Variation
    Puspitasari, Poppy
    Puspitasari, Dewi
    Sasongko, Muhammad Ilman Nur
    Andoko
    Suryanto, Heru
    PROCEEDINGS OF THE INTERNATIONAL MECHANICAL ENGINEERING AND ENGINEERING EDUCATION CONFERENCES (IMEEEC-2016), 2016, 1778
  • [49] Strength and aging resistance of monolithic zirconia: an update to current knowledge
    Kontonasaki, Eleana
    Giasimakopoulos, Panagiotis
    Rigos, Athanasios E.
    JAPANESE DENTAL SCIENCE REVIEW, 2020, 56 (01) : 1 - 23
  • [50] Influence of aging on flexural strength of translucent zirconia for monolithic restorations
    Flinn, Brian D.
    Raigrodski, Ariel J.
    Mancl, Lloyd A.
    Toivola, Ryan
    Kuykendall, Tuesday
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (02): : 303 - 309