Radiotherapy of prostate cancer with or without intensity modulated beams: A planning comparison

被引:129
|
作者
De Meerleer, GO [1 ]
Vakaet, LAML [1 ]
De Gersem, WRT [1 ]
De Wagter, C [1 ]
De Naeyer, B [1 ]
De Neve, W [1 ]
机构
[1] State Univ Ghent Hosp, Div Radiotherapy, B-9000 Ghent, Belgium
关键词
D O I
10.1016/S0360-3016(00)00419-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate whether intensity modulated radiotherapy (IMRT) by static segmented beams allows the dose to the main portion of the prostate target to escalate while keeping the maximal dose at the anterior rectal wall at 72 Gy. The value of such IMRT plans was analyzed by comparison with non-IMRT plans using the same beam incidences. Methods and Materials: We performed a planning study on the CT data of 32 consecutive patients with localized adenocarcinoma of the prostate. Three fields in the transverse plane with gantry angles of 0 degrees, 116 degrees, and 244 degrees were isocentered at the center of gravity of the target volume (prostate and seminal vesicles). The geometry of the beams was determined by beam's eye view autocontouring of the target volume with a margin of 1.5 cm. In study 1, the beam weights were determined by a human planner (3D-man) or by computer optimization using a biological objective function with (3D-optim-lim) or without (3D-optim-unlim) a physical term to limit target dose inhomogeneity. In study 2, the 3 beam incidences mentioned above were used and in-field uniform segments were added to allow IMRT. Plans with (IMRT-lim) or without (IMRT-unlim) constraints on target dose inhomogeneity were compared. In the IMRT-lim plan, target dose inhomogeneity was constrained between 15% and 20%. After optimization, plans in both studies were normalized to a maximal rectal dose of 72 Gy. Biological (tumor control probability [TCP], normal tissue complication probability [NTCP]) and physical indices for tumor control and normal tissue complication probabilities were computed, as well as the probability of the uncomplicated local control (P+). Results: The IMRT-lim plan was superior to all other plans concerning TCP (p < 0.0001). The IMRT-unlim plan had the worst TCP. Within the 3D plans, the 3D-optim-unlim had the best TCP, which was significantly different from the 3D-optim-lim plan (p = 0.0003). For rectal NTCP, both IMRT plans were superior to all other plans (p < 0.0001). The IMRT-unlim plan was significantly better than the IMRT-lim plan (p < 0.0001). Again, 3D-optim-unlim was superior to the other 3D plans (p < 0.0007). Physical endpoints for target showed the mean minimal target dose to be the lowest in the IMRT-unlim plan, caused by a large target dose inhomogeneity (TDI). Medial target dose, 90th percentile, and maximal target dose were significantly higher in both IMRT plans. Physical endpoints for the rectum showed the IMRT-unlim plan to be superior compared to all other plans. There was a strong correlation between the 65th percentile (Rp6S) and rectal NTCP (correlation coefficient greater than or equal to 89%). For bladder, maximal bladder dose was significantly higher in the IMRT-unlim plan compared to all other plans (p less than or equal to 0.0001). P+ was significantly higher in both IMRT-plans than in all other plans. The 3D-optim-unlim plan was significantly better than the two other 3D plans (p < 0.0001). Conclusion: IMRT significantly increases the ratio of TCP over NTCP of the rectum in the treatment of prostate cancer. However, constraints for TDI are needed, because a high degree of TDI reduced minimal target dose. IMRT improved uncomplicated local control probability. In our department, IMRT by static segmented beams is planned and delivered in a cost-effective way. IMRT-lim has replaced non-modulated conformal radiotherapy as the standard treatment for prostate cancer. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:639 / 648
页数:10
相关论文
共 50 条
  • [41] Dosimetric Comparison of Intensity-Modulated Proton Therapy and 3D Proton Radiotherapy with Passively Scattered Beams for Primary Prostate Cancer
    Dimofte, A.
    James, P.
    Kassaee, A.
    McDonough, J.
    Tochner, Z.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [42] Volumetric Modulated Arc Therapy for Head and Neck Cancer: A Dosimetric and Treatment Planning Comparison with Intensity Modulated Radiotherapy Techniques
    Goswami, Brijesh
    Yadav, Suresh
    Jain, Rakesh Kumar
    Goswami, Pradeep
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (03)
  • [43] Intensity and energy modulated radiotherapy with proton beams: Variables affecting optimal prostate plan
    Yeboah, C
    Sandison, GA
    Chvetsov, AV
    MEDICAL PHYSICS, 2002, 29 (02) : 176 - 189
  • [44] A comparison of clinical outcomes between three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for prostate cancer
    Takuya Shimizuguchi
    Keiji Nihei
    Tomoyuki Okano
    Yumiko Machitori
    Kei Ito
    Katsuyuki Karasawa
    International Journal of Clinical Oncology, 2017, 22 : 373 - 379
  • [45] A comparison of clinical outcomes between three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for prostate cancer
    Shimizuguchi, Takuya
    Nihei, Keiji
    Okano, Tomoyuki
    Machitori, Yumiko
    Ito, Kei
    Karasawa, Katsuyuki
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2017, 22 (02) : 373 - 379
  • [46] A comparison of sexual function following radiotherapy for prostate cancer: Results of a prospective, randomized trial of hypofractionated intensity modulated radiotherapy
    Buyyounouski, M. K.
    Li, T.
    Watkins-Bruner, D.
    Horwitz, E. M.
    Pollack, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S7 - S8
  • [47] A matched pair comparison of intensity modulated radiotherapy and three-dimensional conformal radiotherapy for prostate cancer: Toxicity and outcomes
    Morgan, P. B.
    Ruth, K.
    Horwitz, E. M.
    Buyyounouski, M. K.
    Uzzo, R. G.
    Pollack, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S319 - S319
  • [48] Comparison of intensity modulated photon radiotherapy with fixed beams, tomotherapy and intensity modulated proton therapy for selected case classes
    Muzik, J.
    Soukup, M.
    Alber, M.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S201 - S201
  • [49] Intensity modulated radiotherapy treatment for prostate cancer, first experience in Chile
    Besa D C, Pelayo
    Rosso A, Roberto
    Bustos C, Marisa
    Borghero, Yerko
    Trucco B, Cristian
    Mac-Namara H, Macarena
    REVISTA MEDICA DE CHILE, 2011, 139 (11) : 1451 - 1457
  • [50] Clinical and physical quality assurance for intensity modulated radiotherapy of prostate cancer
    Boehmer, D
    Bohsung, J
    Eichwurzel, I
    Moys, A
    Budach, V
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 (03) : 319 - 325