Radiotherapy of prostate cancer with or without intensity modulated beams: A planning comparison

被引:129
|
作者
De Meerleer, GO [1 ]
Vakaet, LAML [1 ]
De Gersem, WRT [1 ]
De Wagter, C [1 ]
De Naeyer, B [1 ]
De Neve, W [1 ]
机构
[1] State Univ Ghent Hosp, Div Radiotherapy, B-9000 Ghent, Belgium
关键词
D O I
10.1016/S0360-3016(00)00419-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate whether intensity modulated radiotherapy (IMRT) by static segmented beams allows the dose to the main portion of the prostate target to escalate while keeping the maximal dose at the anterior rectal wall at 72 Gy. The value of such IMRT plans was analyzed by comparison with non-IMRT plans using the same beam incidences. Methods and Materials: We performed a planning study on the CT data of 32 consecutive patients with localized adenocarcinoma of the prostate. Three fields in the transverse plane with gantry angles of 0 degrees, 116 degrees, and 244 degrees were isocentered at the center of gravity of the target volume (prostate and seminal vesicles). The geometry of the beams was determined by beam's eye view autocontouring of the target volume with a margin of 1.5 cm. In study 1, the beam weights were determined by a human planner (3D-man) or by computer optimization using a biological objective function with (3D-optim-lim) or without (3D-optim-unlim) a physical term to limit target dose inhomogeneity. In study 2, the 3 beam incidences mentioned above were used and in-field uniform segments were added to allow IMRT. Plans with (IMRT-lim) or without (IMRT-unlim) constraints on target dose inhomogeneity were compared. In the IMRT-lim plan, target dose inhomogeneity was constrained between 15% and 20%. After optimization, plans in both studies were normalized to a maximal rectal dose of 72 Gy. Biological (tumor control probability [TCP], normal tissue complication probability [NTCP]) and physical indices for tumor control and normal tissue complication probabilities were computed, as well as the probability of the uncomplicated local control (P+). Results: The IMRT-lim plan was superior to all other plans concerning TCP (p < 0.0001). The IMRT-unlim plan had the worst TCP. Within the 3D plans, the 3D-optim-unlim had the best TCP, which was significantly different from the 3D-optim-lim plan (p = 0.0003). For rectal NTCP, both IMRT plans were superior to all other plans (p < 0.0001). The IMRT-unlim plan was significantly better than the IMRT-lim plan (p < 0.0001). Again, 3D-optim-unlim was superior to the other 3D plans (p < 0.0007). Physical endpoints for target showed the mean minimal target dose to be the lowest in the IMRT-unlim plan, caused by a large target dose inhomogeneity (TDI). Medial target dose, 90th percentile, and maximal target dose were significantly higher in both IMRT plans. Physical endpoints for the rectum showed the IMRT-unlim plan to be superior compared to all other plans. There was a strong correlation between the 65th percentile (Rp6S) and rectal NTCP (correlation coefficient greater than or equal to 89%). For bladder, maximal bladder dose was significantly higher in the IMRT-unlim plan compared to all other plans (p less than or equal to 0.0001). P+ was significantly higher in both IMRT-plans than in all other plans. The 3D-optim-unlim plan was significantly better than the two other 3D plans (p < 0.0001). Conclusion: IMRT significantly increases the ratio of TCP over NTCP of the rectum in the treatment of prostate cancer. However, constraints for TDI are needed, because a high degree of TDI reduced minimal target dose. IMRT improved uncomplicated local control probability. In our department, IMRT by static segmented beams is planned and delivered in a cost-effective way. IMRT-lim has replaced non-modulated conformal radiotherapy as the standard treatment for prostate cancer. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:639 / 648
页数:10
相关论文
共 50 条
  • [31] Stereotactic body radiosurgery versus intensity modulated radiotherapy for prostate cancer: Comparison of toxicity.
    Yu, James B.
    Cramer, Laura D.
    Herrin, Jeph
    Soulos, Pamela R.
    Potosky, Arnold L.
    Gross, Cary
    JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (04)
  • [32] Dosimetric comparison of different multileaf collimator widths in the treatment of prostate cancer with intensity modulated radiotherapy
    Wang, L
    Jacob, R
    Movsas, B
    Chen, L
    Fourkal, E
    Ma, C
    Pollack, A
    MEDICAL PHYSICS, 2003, 30 (06) : 1405 - 1405
  • [33] Static and rotational intensity modulated techniques for head-neck cancer radiotherapy: A planning comparison
    Broggi, Sara
    Perna, Lucia
    Bonsignore, Francesco
    Rinaldin, Giuseppe
    Fiorino, Claudio
    Chiara, Anna
    Frigerio, Cristina
    Butti, Ivana
    Sangalli, Giulia
    Dell'Oca, Italo
    Di Muzio, Nadia
    Cattaneo, Giovanni Mauro
    Declich, Fausto
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (08): : 973 - 979
  • [34] The magnetic resonance detected intraprostatic lesion in prostate cancer: planning and delivery of intensity-modulated radiotherapy
    De Meerleer, G
    Villeirs, G
    Bral, S
    Paelinck, L
    De Gersem, W
    Dekuyper, P
    De Neve, W
    RADIOTHERAPY AND ONCOLOGY, 2005, 75 (03) : 325 - 333
  • [35] Adverse effect of a distended rectum in intensity-modulated radiotherapy (IMRT) treatment planning of prostate cancer
    Guckenberger, M
    Pohl, F
    Baier, K
    Meyer, J
    Vordermark, D
    Flentje, M
    RADIOTHERAPY AND ONCOLOGY, 2006, 79 (01) : 59 - 64
  • [36] A comparison of forward and inverse treatment planning for intensity-modulated radiotherapy of head and neck cancer
    Bär, W
    Schwarz, M
    Alber, M
    Bos, LJ
    Mijnheer, BJ
    Rasch, C
    Schneider, C
    Nüsslin, F
    Damen, EMF
    RADIOTHERAPY AND ONCOLOGY, 2003, 69 (03) : 251 - 258
  • [37] Planning of intensity modulated radiotherapy in low dose rate iodine 125 brachytherapy of localized prostate cancer
    Zimmermann, JS
    Drexler, C
    Feigl, M
    Schneider, J
    STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 : 62 - 62
  • [38] Prostate intensity-modulated radiotherapy planning in seven mouse clicks: Development of a class solution for cancer
    Wood, Maree
    Fonseca, Amara
    Sampson, David
    Kovendy, Andrew
    Westhuyzen, Justin
    Shakespeare, Thomas
    Turnbull, Kirsty
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2016, 21 (06) : 567 - 570
  • [39] Robust treatment planning for intensity modulated radiotherapy (IMRT) treatment of prostate cancer based on coverage probabilities
    Baum, C
    Birkner, M
    Alber, M
    Nüsslin, F
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S91 - S91
  • [40] Fluence map optimisation for prostate cancer intensity modulated radiotherapy planning using iterative solution method
    Singh, Pushpendra
    Tripathi, Supriya
    Tamrakar, Raunak Kumar
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2020, 26 (04): : 201 - 209