Radiotherapy of prostate cancer with or without intensity modulated beams: A planning comparison

被引:129
|
作者
De Meerleer, GO [1 ]
Vakaet, LAML [1 ]
De Gersem, WRT [1 ]
De Wagter, C [1 ]
De Naeyer, B [1 ]
De Neve, W [1 ]
机构
[1] State Univ Ghent Hosp, Div Radiotherapy, B-9000 Ghent, Belgium
关键词
D O I
10.1016/S0360-3016(00)00419-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate whether intensity modulated radiotherapy (IMRT) by static segmented beams allows the dose to the main portion of the prostate target to escalate while keeping the maximal dose at the anterior rectal wall at 72 Gy. The value of such IMRT plans was analyzed by comparison with non-IMRT plans using the same beam incidences. Methods and Materials: We performed a planning study on the CT data of 32 consecutive patients with localized adenocarcinoma of the prostate. Three fields in the transverse plane with gantry angles of 0 degrees, 116 degrees, and 244 degrees were isocentered at the center of gravity of the target volume (prostate and seminal vesicles). The geometry of the beams was determined by beam's eye view autocontouring of the target volume with a margin of 1.5 cm. In study 1, the beam weights were determined by a human planner (3D-man) or by computer optimization using a biological objective function with (3D-optim-lim) or without (3D-optim-unlim) a physical term to limit target dose inhomogeneity. In study 2, the 3 beam incidences mentioned above were used and in-field uniform segments were added to allow IMRT. Plans with (IMRT-lim) or without (IMRT-unlim) constraints on target dose inhomogeneity were compared. In the IMRT-lim plan, target dose inhomogeneity was constrained between 15% and 20%. After optimization, plans in both studies were normalized to a maximal rectal dose of 72 Gy. Biological (tumor control probability [TCP], normal tissue complication probability [NTCP]) and physical indices for tumor control and normal tissue complication probabilities were computed, as well as the probability of the uncomplicated local control (P+). Results: The IMRT-lim plan was superior to all other plans concerning TCP (p < 0.0001). The IMRT-unlim plan had the worst TCP. Within the 3D plans, the 3D-optim-unlim had the best TCP, which was significantly different from the 3D-optim-lim plan (p = 0.0003). For rectal NTCP, both IMRT plans were superior to all other plans (p < 0.0001). The IMRT-unlim plan was significantly better than the IMRT-lim plan (p < 0.0001). Again, 3D-optim-unlim was superior to the other 3D plans (p < 0.0007). Physical endpoints for target showed the mean minimal target dose to be the lowest in the IMRT-unlim plan, caused by a large target dose inhomogeneity (TDI). Medial target dose, 90th percentile, and maximal target dose were significantly higher in both IMRT plans. Physical endpoints for the rectum showed the IMRT-unlim plan to be superior compared to all other plans. There was a strong correlation between the 65th percentile (Rp6S) and rectal NTCP (correlation coefficient greater than or equal to 89%). For bladder, maximal bladder dose was significantly higher in the IMRT-unlim plan compared to all other plans (p less than or equal to 0.0001). P+ was significantly higher in both IMRT-plans than in all other plans. The 3D-optim-unlim plan was significantly better than the two other 3D plans (p < 0.0001). Conclusion: IMRT significantly increases the ratio of TCP over NTCP of the rectum in the treatment of prostate cancer. However, constraints for TDI are needed, because a high degree of TDI reduced minimal target dose. IMRT improved uncomplicated local control probability. In our department, IMRT by static segmented beams is planned and delivered in a cost-effective way. IMRT-lim has replaced non-modulated conformal radiotherapy as the standard treatment for prostate cancer. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:639 / 648
页数:10
相关论文
共 50 条
  • [21] Treatment Efficiency of Volumetric Modulated Arc Therapy in Comparison With Intensity-Modulated Radiotherapy in the Treatment of Prostate Cancer
    Hall, William A.
    Fox, Timothy H.
    Jiang, Xiaojun
    Prabhu, Roshan S.
    Rossi, Peter J.
    Godette, Karen
    Jani, Ashesh B.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (02) : 128 - 134
  • [22] Volumetric modulated arc therapy in differentiated thyroid cancer: a treatment planning comparison with intensity-modulated radiotherapy
    Chan, Wing Lok
    Ng, Sherry C. Y.
    Law, Martin W. M.
    Lee, Victor H. F.
    Wan, K. Y.
    Leung, T. W.
    JOURNAL OF RADIATION ONCOLOGY, 2015, 4 (04) : 417 - 422
  • [23] Expanding Utilization of Intensity-Modulated Radiotherapy for Prostate Cancer
    Cooperberg, Matthew R.
    JAMA INTERNAL MEDICINE, 2013, 173 (12) : 1143 - 1144
  • [24] Dose painting in intensity-modulated radiotherapy for prostate cancer
    Oehler, W
    Baum, RP
    Buth, KJ
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 53 - 53
  • [25] Localized prostate cancer treated with intensity-modulated radiotherapy
    Livi, Lorenzo
    Paiar, Fabiola
    Banci-Buonamici, Fabrizio
    Simontacchi, Gabriele
    Detti, Beatrice
    Gacci, Mauro
    Mondaini, Nicola
    Nelli, Federico
    Bastiani, Paolo
    Pertici, Maurizio
    Mungai, Raffaello
    Ponticelli, Pietro
    Biti, Giampaolo
    TUMORI, 2006, 92 (03) : 197 - 201
  • [26] 3 dimensional radiotherapy versus intensity modulated radiotherapy for localised prostate cancer - a three technique plan comparison
    Viotto, A
    Joon, DL
    Mantle, C
    Rolfo, A
    Wada, M
    Rykers, K
    Grace, M
    Fernando, W
    Joon, ML
    Khoo, V
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S333 - S333
  • [27] Implementation of intensity modulated radiotherapy for prostate cancer in a private radiotherapy service in Mexico
    Adela Poitevin-Chacon, Maria
    Resendiz Gonzalez, Gabriel
    Alvarado Zermeno, Adriana
    Flores Castro, Jesus Manuel
    Flores Balcazar, Christian Haydee
    Rosales Perez, Samuel
    Perez Pastenes, Miguel Angel
    Rodriguez Laguna, Alejandro
    Vazquez Fernandez, Patricio
    Calvo Fernandez, Alejandro
    Ventura, Jorge Bastida
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (01) : 66 - 71
  • [28] Dosimetric consequences of the application of a rectum hull-planning volume for treatment planning of intensity modulated radiotherapy of prostate cancer
    Baum, Christoph
    Alber, Markus
    Nuesslin, Fridtjof
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (03): : 208 - 216
  • [29] Dosimetric comparison of intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy in patients with prostate cancer: a meta-analysis
    Ren, Wenting
    Sun, Chao
    Lu, Ningning
    Xu, Yingjie
    Han, Fei
    Liu, Yue Ping
    Dai, Jianrong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 254 - 262
  • [30] Dose-volume comparison of proton therapy and intensity-modulated radiotherapy for prostate cancer
    Vargas, Carlos
    Fryer, Amber
    Mahajan, Chaitali
    Indelicato, Daniel
    Horne, David
    Chellini, Angela
    Mckenzie, Craig
    Lawlor, Paula
    Henderson, Randal
    Li, Zuofeng
    Lin, Liyong
    Olivier, Kenneth
    Keole, Sameer
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (03): : 744 - 751