Computation of the glandular radiation dose in digital tomosynthesis of the breast

被引:112
|
作者
Sechopoulos, Ioannis
Suryanarayanan, Sankarararnan
Vedantham, Srinivasan
D'Orsi, Carl
Karellas, Andrew
机构
[1] Emory Univ, Sch Med, Dept Radiol, Atlanta, GA 30322 USA
[2] Winship Canc Inst, Atlanta, GA 30322 USA
[3] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
关键词
D O I
10.1118/1.2400836
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tomosynthesis of the breast is currently a topic of intense interest as a logical next step in the evolution of digital mammography. This study reports on the computation of glandular radiation dose in digital tomosynthesis of the breast. Previously, glandular dose estimations in tomosynthesis have been performed using data from studies of radiation dose in conventional planar mammography. This study evaluates, using Monte Carlo methods, the normalized glandular dose (DgN) to the breast during a tomosynthesis study, and characterizes its dependence on breast size, tissue composition, and x-ray spectrum. The conditions during digital tomosynthesis imaging of the breast were simulated using a computer program based on the Geant4 toolkit. With the use of simulated breasts of varying size, thickness and tissue composition, the DgN to the breast tissue was computed for varying x-ray spectra and tomosynthesis projection angle. Tomosynthesis projections centered about both the cranio-caudal (CC) and medio-lateral oblique (MLO) views were simulated. For each projection angle, the ratio of the glandular dose for that projection to the glandular dose for the zero degree projection was computed. This ratio was denoted the relative glandular dose (RGD) coefficient, and its variation under different imaging parameters was analyzed. Within mammoaraphic energies, the RGD was found to have a weak dependence on glandular fraction and x-ray spectrum for both views. A substantial dependence on breast size and thickness was found for the MLO view, and to a lesser extent for the CC view. Although RGD values deviate substantially from unity as a function of projection angle, the RGD averaged over all projections in a complete tomosynthesis study varies from 0.91 to 1.01. The RGD results were fit to mathematical functions and the resulting equations are provided. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:221 / 232
页数:12
相关论文
共 50 条
  • [1] Average Glandular Dose in Digital Mammography and Breast Tomosynthesis
    Olgar, T.
    Kahn, T.
    Gosch, D.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (10): : 911 - 918
  • [2] Automated Breast Density Computation in Digital Mammography and Digital Breast Tomosynthesis: Influence on Mean Glandular Dose and BIRADS Density Categorization
    Castillo-Garcia, Maria
    Chevalier, Margarita
    Garayoa, Julia
    Rodriguez-Ruiz, Alejandro
    Garcia-Pinto, Diego
    Valverde, Julio
    [J]. ACADEMIC RADIOLOGY, 2017, 24 (07) : 802 - 810
  • [3] Glandular radiation dose in tomosynthesis of the breast using tungsten targets
    Sechopoulos, Ioannis
    D'Orsi, Carl J.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (04): : 161 - 171
  • [4] Normalized glandular dose coefficients in mammography, digital breast tomosynthesis and dedicated breast CT
    Sarno, A.
    Mettivier, G.
    Di Lillo, F.
    Tucciariello, R. M.
    Bliznakova, K.
    Russo, P.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 55 : 142 - 148
  • [5] Monte Carlo simulation for the estimation of the glandular breast dose for a digital breast tomosynthesis system
    Rodrigues, Leonardo
    Goncalves Magalhaes, Luis Alexandre
    Braz, Delson
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 167 (04) : 576 - 583
  • [6] Normalized glandular dose coefficients for digital breast tomosynthesis systems with a homogeneous breast model
    Sarno, Antonio
    Tucciariello, Raffaele Maria
    Mettivier, Giovanni
    Del Sarto, Damiano
    Fantacci, Maria Evelina
    Russo, Paolo
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06):
  • [7] Impact of age and breast thickness on mean glandular dose of standard digital mammography and digital breast tomosynthesis
    Norsuddin, Norhashimah Mohd
    Sin, Justine Go Mei
    Ravintaran, Rathieswari
    Arasaratnam, Shantini
    Karim, Muhammad Khalis Abdul
    [J]. APPLIED RADIATION AND ISOTOPES, 2023, 192
  • [8] EFFECT OF THE GLANDULAR COMPOSITION ON DIGITAL BREAST TOMOSYNTHESIS IMAGE QUALITY AND DOSE OPTIMISATION
    Marques, T.
    Ribeiro, A.
    Di Maria, S.
    Belchior, A.
    Cardoso, J.
    Matela, N.
    Oliveira, N.
    Janeiro, L.
    Almeida, P.
    Vaz, P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 337 - 341
  • [9] Average glandular dose in digital mammography and digital breast tomosynthesis: comparison of phantom and patient data
    Bouwman, R. W.
    van Engen, R. E.
    Young, K. C.
    den Heeten, G. J.
    Broeders, M. J. M.
    Schopphoven, S.
    Jeukens, C. R. L. P. N.
    Veldkamp, W. J. H.
    Dance, D. R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20): : 7893 - 7907
  • [10] Normalized glandular dose coefficients for digital breast tomosynthesis using detailed Chinese breast models
    Wang, Jia-Hao
    Qiu, Rui
    Hu, An-Kang
    Liu, Ye-Qi
    Wu, Zhen
    Zhang, Hui
    Li, Jun-Li
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (05)