Computation of the glandular radiation dose in digital tomosynthesis of the breast

被引:111
|
作者
Sechopoulos, Ioannis
Suryanarayanan, Sankarararnan
Vedantham, Srinivasan
D'Orsi, Carl
Karellas, Andrew
机构
[1] Emory Univ, Sch Med, Dept Radiol, Atlanta, GA 30322 USA
[2] Winship Canc Inst, Atlanta, GA 30322 USA
[3] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
关键词
D O I
10.1118/1.2400836
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tomosynthesis of the breast is currently a topic of intense interest as a logical next step in the evolution of digital mammography. This study reports on the computation of glandular radiation dose in digital tomosynthesis of the breast. Previously, glandular dose estimations in tomosynthesis have been performed using data from studies of radiation dose in conventional planar mammography. This study evaluates, using Monte Carlo methods, the normalized glandular dose (DgN) to the breast during a tomosynthesis study, and characterizes its dependence on breast size, tissue composition, and x-ray spectrum. The conditions during digital tomosynthesis imaging of the breast were simulated using a computer program based on the Geant4 toolkit. With the use of simulated breasts of varying size, thickness and tissue composition, the DgN to the breast tissue was computed for varying x-ray spectra and tomosynthesis projection angle. Tomosynthesis projections centered about both the cranio-caudal (CC) and medio-lateral oblique (MLO) views were simulated. For each projection angle, the ratio of the glandular dose for that projection to the glandular dose for the zero degree projection was computed. This ratio was denoted the relative glandular dose (RGD) coefficient, and its variation under different imaging parameters was analyzed. Within mammoaraphic energies, the RGD was found to have a weak dependence on glandular fraction and x-ray spectrum for both views. A substantial dependence on breast size and thickness was found for the MLO view, and to a lesser extent for the CC view. Although RGD values deviate substantially from unity as a function of projection angle, the RGD averaged over all projections in a complete tomosynthesis study varies from 0.91 to 1.01. The RGD results were fit to mathematical functions and the resulting equations are provided. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:221 / 232
页数:12
相关论文
共 50 条
  • [21] Lesion assessment and radiation dose in Contrast-Enhanced Digital Breast Tomosynthesis
    Huang, Hailiang
    Scaduto, David A.
    Liu, Chunling
    Yang, Jie
    Zhu, Chencan
    Rinaldi, Kim
    Eisenberg, Jason
    Liu, Jingxuan
    Hoernig, Mathias
    Wicklein, Julia
    Vogt, Sebastian
    Mertelmeier, Thomas
    Fisher, Paul R.
    Zhao, Wei
    14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [22] Average absorbed breast dose (2ABD): an easy radiation dose index for digital breast tomosynthesis
    Traino, Antonio C.
    Barca, Patrizio
    Lamastra, Rocco
    Tucciariello, Raffaele M.
    Sottocornola, Chiara
    Marini, Carolina
    Aringhieri, Giacomo
    Caramella, Davide
    Fantacci, Maria E.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [23] Radiation dose with digital breast tomosynthesis compared to digital mammography: per-view analysis
    Gennaro, Gisella
    Bernardi, D.
    Houssami, N.
    EUROPEAN RADIOLOGY, 2018, 28 (02) : 573 - 581
  • [24] Radiation dose from digital breast tomosynthesis screening - A comparison with full field digital mammography
    Ali, Raed M. K. M.
    England, Andrew
    Tootell, Andrew K.
    Hogg, Peter
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2020, 51 (04) : 599 - 603
  • [25] Radiation dose with digital breast tomosynthesis compared to digital mammography: per-view analysis
    Gisella Gennaro
    D. Bernardi
    N. Houssami
    European Radiology, 2018, 28 : 573 - 581
  • [26] Average absorbed breast dose (2ABD): an easy radiation dose index for digital breast tomosynthesis
    Antonio C. Traino
    Patrizio Barca
    Rocco Lamastra
    Raffaele M. Tucciariello
    Chiara Sottocornola
    Carolina Marini
    Giacomo Aringhieri
    Davide Caramella
    Maria E. Fantacci
    European Radiology Experimental, 4
  • [27] PATIENT DOSE EVALUATION IN DIGITAL BREAST TOMOSYNTHESIS
    Kisielewicz, K.
    Rawojc, K.
    Dziubinska, A.
    Mazur, L.
    Kieltyka, B.
    Najberg-Pierzchala, D.
    Gadek, M.
    Luczynska, E.
    Wos, Z.
    Heinze, S.
    Dziecichowicz, A.
    ACTA PHYSICA POLONICA B, 2020, 51 (01): : 345 - 349
  • [28] Simulation of Dose Reduction in Digital Breast Tomosynthesis
    Borges, Lucas R.
    Guerrero, Igor
    Bakic, Predrag R.
    Maidment, Andrew D. A.
    Schiabel, Homero
    Vieira, Marcelo A. C.
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 343 - 350
  • [29] Evaluation of average glandular dose and investigation of the relationship with compressed breast thickness in dual energy contrast enhanced digital mammography and digital breast tomosynthesis
    Fusco, Roberta
    Raiano, Nicola
    Raiano, Concetta
    Maio, Francesca
    Vallone, Paolo
    Raso, Mauro Mattace
    Setola, Sergio Venanzio
    Granata, Vincenza
    Rubulotta, Maria Rosaria
    Barretta, Maria Lusia
    Petrosino, Teresa
    Petrillo, Antonella
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 126
  • [30] Comparisons of glandular breast dose between digital mammography, tomosynthesis and breast CT based on anthropomorphic patient-derived breast phantoms
    Sarno, Antonio
    Mettivier, Giovanni
    Bliznakova, Kristina
    Hernandez, Andrew M.
    Boone, John M.
    Russo, Paolo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 97 : 50 - 58