Computation of the glandular radiation dose in digital tomosynthesis of the breast

被引:111
|
作者
Sechopoulos, Ioannis
Suryanarayanan, Sankarararnan
Vedantham, Srinivasan
D'Orsi, Carl
Karellas, Andrew
机构
[1] Emory Univ, Sch Med, Dept Radiol, Atlanta, GA 30322 USA
[2] Winship Canc Inst, Atlanta, GA 30322 USA
[3] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
关键词
D O I
10.1118/1.2400836
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tomosynthesis of the breast is currently a topic of intense interest as a logical next step in the evolution of digital mammography. This study reports on the computation of glandular radiation dose in digital tomosynthesis of the breast. Previously, glandular dose estimations in tomosynthesis have been performed using data from studies of radiation dose in conventional planar mammography. This study evaluates, using Monte Carlo methods, the normalized glandular dose (DgN) to the breast during a tomosynthesis study, and characterizes its dependence on breast size, tissue composition, and x-ray spectrum. The conditions during digital tomosynthesis imaging of the breast were simulated using a computer program based on the Geant4 toolkit. With the use of simulated breasts of varying size, thickness and tissue composition, the DgN to the breast tissue was computed for varying x-ray spectra and tomosynthesis projection angle. Tomosynthesis projections centered about both the cranio-caudal (CC) and medio-lateral oblique (MLO) views were simulated. For each projection angle, the ratio of the glandular dose for that projection to the glandular dose for the zero degree projection was computed. This ratio was denoted the relative glandular dose (RGD) coefficient, and its variation under different imaging parameters was analyzed. Within mammoaraphic energies, the RGD was found to have a weak dependence on glandular fraction and x-ray spectrum for both views. A substantial dependence on breast size and thickness was found for the MLO view, and to a lesser extent for the CC view. Although RGD values deviate substantially from unity as a function of projection angle, the RGD averaged over all projections in a complete tomosynthesis study varies from 0.91 to 1.01. The RGD results were fit to mathematical functions and the resulting equations are provided. (c) 2007 American Association of Physicists in Medicine.
引用
下载
收藏
页码:221 / 232
页数:12
相关论文
共 50 条
  • [41] Digital breast tomosynthesis and digital mammography: A comparison of figures of merit for various average glandular doses
    Kim, Ye-seul
    Park, Hye-Suk
    Park, SuJin
    Kim, Hee-Joung
    Choi, Jae-Gu
    Choi, Young-Wook
    Park, Jun-Ho
    Lee, Jae-Jun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 62 (09) : 1346 - 1353
  • [42] Simultaneous measurement of patient dose and distribution of indoor scattered radiation during digital breast tomosynthesis
    Nakamura, T.
    Suzuki, S.
    Takei, Y.
    Kobayashi, I
    Pongnapang, N.
    Kato, K.
    RADIOGRAPHY, 2019, 25 (01) : 72 - 76
  • [43] Digital breast tomosynthesis and digital mammography: A comparison of figures of merit for various average glandular doses
    Ye-seul Kim
    Hye-Suk Park
    SuJin Park
    Hee-Joung Kim
    Jae-Gu Choi
    Young-Wook Choi
    Jun-Ho Park
    Jae-Jun Lee
    Journal of the Korean Physical Society, 2013, 62 : 1346 - 1353
  • [44] Assessment of scatter radiation dose received by comforters and carers during digital breast tomosynthesis mammography
    Kostidis, Michelle
    Varcoe, Joshua G.
    Barnes, Peter
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2023, 70 (02) : 112 - 119
  • [45] In vivo average glandular dose evaluation: one-to-one comparison between digital breast tomosynthesis and full-field digital mammography
    Cavagnetto, Francesca
    Taccini, Gianni
    Rosasco, Raffaella
    Bampi, Rossana
    Calabrese, Massimo
    Tagliafico, Alberto
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (01) : 53 - 61
  • [46] Glandular dose in breast computed tomography with synchrotron radiation
    Mettivier, G.
    Fedon, C.
    Di Lillo, F.
    Longo, R.
    Sarno, A.
    Tromba, G.
    Russo, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 569 - 587
  • [47] Eye radiation dose from breast cancer screening using full field digital mammography and digital breast tomosynthesis: A phantom study
    Ali, R. M. K. M.
    Hogg, P.
    RADIOGRAPHY, 2024, 30 (01) : 141 - 144
  • [48] Comparison of radiation dose between 2D digital stereotactic versus digital breast tomosynthesis-guided breast biopsies
    Amir, T.
    Zuckerman, S. P.
    Barufaldi, B.
    Maidment, A. D.
    Conant, E. F.
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 134
  • [49] COMPARISON OF SPECTRA AND MEAN GLANDULAR DOSE WITH TUBE VOLTAGES USED IN DIGITAL BREAST TOMOSYNTHESIS FROM SIMULATED, METROLOGICAL AND CLINICAL CASES
    da Silveira Gatto, Leandro Barbosa
    Braz, Delson
    Pacifico, Leonardo
    Travassos, Paulo
    Goncalves Magalhaes, Luis Alexandre
    RADIATION PROTECTION DOSIMETRY, 2020, 192 (03) : 402 - 412
  • [50] Single Center Evaluation of Comparative Breast Radiation dose of Contrast Enhanced Digital Mammography (CEDM), Digital Mammography (DM) and Digital Breast Tomosynthesis (DBT)
    Bicchierai, Giulia
    Busoni, Simone
    Tortoli, Paolo
    Bettarini, Silvia
    Di Naro, Federica
    De Benedetto, Diego
    Savi, Elena
    Bellini, Chiara
    Miele, Vittorio
    Nori, Jacopo
    ACADEMIC RADIOLOGY, 2022, 29 (09) : 1342 - 1349