Lesion assessment and radiation dose in Contrast-Enhanced Digital Breast Tomosynthesis

被引:1
|
作者
Huang, Hailiang [1 ]
Scaduto, David A. [1 ]
Liu, Chunling [1 ]
Yang, Jie [2 ]
Zhu, Chencan [2 ]
Rinaldi, Kim [1 ]
Eisenberg, Jason [1 ]
Liu, Jingxuan [3 ]
Hoernig, Mathias [4 ]
Wicklein, Julia [4 ]
Vogt, Sebastian [5 ]
Mertelmeier, Thomas [4 ]
Fisher, Paul R. [1 ]
Zhao, Wei [1 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
[2] SUNY Stony Brook, Dept Family Populat & Prevent Med, Stony Brook, NY 11794 USA
[3] SUNY Stony Brook, Dept Pathol, Stony Brook, NY 11794 USA
[4] Siemens Healthineers, Forchheim, Germany
[5] Siemens Med Solut USA, Monument, CO USA
关键词
Contrast Enhanced Digital Breast Tomosynthesis; Contrast Enhanced Digital Mammography; Synthetic contrast enhanced digital mammography; SPECTRAL MAMMOGRAPHY; CANCER;
D O I
10.1117/12.2316371
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Contrast-Enhanced Digital Breast Tomosynthesis (CEDBT) provides a three-dimensional (3D) contrast-enhancement map with co-registered anatomical information from low-energy DBT. It combines the benefits from Contrast-Enhanced Digital Mammography (CEDM) and Digital Breast Tomosynthesis (DBT), and may improve breast cancer detection and assessment of lesion morphology. We investigate the efficacy of CEDBT in the assessment of lesion contrast enhancement and margin identification, and evaluate the dose efficiency. We generate synthetic CEDM images from CEDBT data, similar to synthesis of 2D mammograms from DBT data, which may facilitate overall lesion assessment without additional radiation dose. Preliminary results from a patient study show that CEDBT depicts lesion margins better compared to CEDM, while the contrast-enhancement level for in-plane slice is not as high as in CEDM. CEDBT delivers less radiation dose compared to CEDM + DBT. Synthetic CEDM is able to provide lesion contrast-enhancement level comparable to CEDM.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Comparison of contrast-enhanced digital mammography and contrast-enhanced digital breast tomosynthesis for lesion assessment Comparison of contrast-enhanced
    Huang, Hailiang
    Scaduto, David A.
    Liu, Chunling
    Yang, Jie
    Zhu, Chencan
    Rinaldi, Kim
    Eisenberg, Jason
    Liu, Jingxuan
    Hoernig, Mathias
    Wicklein, Julia
    Vogt, Sebastian
    Mertelmeier, Thomas
    Fisher, Paul R.
    Zhao, Wei
    [J]. JOURNAL OF MEDICAL IMAGING, 2019, 6 (03)
  • [2] Effects of angular range on lesion margin assessment in Contrast-Enhanced Digital Breast Tomosynthesis
    Huang, Hailiang
    Scaduto, David A.
    Rinaldi, Kim
    Liu, Jingxuan
    Wicklein, Julia
    Hoernig, Mathias
    Mertelmeier, Thomas
    Fisher, Paul R.
    Zhao, Wei
    [J]. MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [3] Dependence of Contrast-Enhanced Lesion Detection in Contrast-Enhanced Digital Breast Tomosynthesis on Imaging Chain Design
    Scaduto, David A.
    Hu, Yue-Houng
    Lu, Yihuan
    Huang, Hailiang
    Liu, Jingxuan
    Rinaldi, Kim
    Gindi, Gene
    Fisher, Paul R.
    Zhao, Wei
    [J]. BREAST IMAGING, IWDM 2016, 2016, 9699 : 136 - 144
  • [4] Quantification of contrast-enhanced digital breast tomosynthesis
    Maidment, A. D. A.
    Carton, A. -K.
    Chen, S.
    Conant, E. F.
    Schnal, M.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 12 - 14
  • [5] Optimization of contrast-enhanced digital breast tomosynthesis
    Carton, Ann-Katherine
    Li, Jingjing
    Chen, Sara
    Conant, Emily
    Maidment, Andrew D. A.
    [J]. DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 183 - 189
  • [6] Quantification for contrast-enhanced digital breast tomosynthesis
    Carton, Ann-Katherine
    Li, Jingjing
    Albert, Michael
    Chen, Sara
    Maidment, Andrew D. A.
    [J]. MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [7] Comparative Dose of Contrast-Enhanced Spectral Mammography (CESM), Digital Mammography, and Digital Breast Tomosynthesis
    Phillips, Jordana
    Mihai, Georgeta
    Hassonjee, Sarah Esaa
    Raj, Sean D.
    Palmer, Matthew R.
    Brook, Alexander
    Zhang, Da
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (04) : 839 - 846
  • [8] Breast Digital Tomosynthesis versus Contrast-Enhanced Mammography: Comparison of Diagnostic Application and Radiation Dose in a Screening Setting
    Nicosia, Luca
    Bozzini, Anna Carla
    Pesapane, Filippo
    Rotili, Anna
    Marinucci, Irene
    Signorelli, Giulia
    Frassoni, Samuele
    Bagnardi, Vincenzo
    Origgi, Daniela
    De Marco, Paolo
    Abiuso, Ida
    Sangalli, Claudia
    Balestreri, Nicola
    Corso, Giovanni
    Cassano, Enrico
    [J]. CANCERS, 2023, 15 (09)
  • [9] Initial clinical experience with contrast-enhanced digital breast tomosynthesis
    Chen, Sara C.
    Carton, Ann-Katherine
    Albert, Michael
    Conant, Emily F.
    Schnall, Mitchell D.
    Maidment, Andrew D. A.
    [J]. ACADEMIC RADIOLOGY, 2007, 14 (02) : 229 - 238
  • [10] Breast tomosynthesis and contrast-enhanced digital mammography: Competitiveness or complementary?
    Valfort, Alix
    Jalaguier-Coudray, Aurelie
    Villard-Mahjoub, Rim
    [J]. IMAGERIE DE LA FEMME, 2019, 29 (01) : 4 - 7