Comparative Dose of Contrast-Enhanced Spectral Mammography (CESM), Digital Mammography, and Digital Breast Tomosynthesis

被引:39
|
作者
Phillips, Jordana [1 ,2 ]
Mihai, Georgeta [1 ,2 ]
Hassonjee, Sarah Esaa [1 ,2 ]
Raj, Sean D. [1 ,2 ]
Palmer, Matthew R. [1 ,2 ]
Brook, Alexander [1 ,2 ]
Zhang, Da [1 ,2 ]
机构
[1] Harvard Med Sch, Dept Radiol, 330 Brookline Ave,4th Fl, Boston, MA 02215 USA
[2] Beth Israel Deaconess Med Ctr, 330 Brookline Ave,4th Fl, Boston, MA 02215 USA
关键词
contrast-enhanced digital mammography; contrast-enhanced mammography; contrast-enhanced spectral mammography; radiation dose; DOSIMETRY PROTOCOLS; RADIATION-EXPOSURE; PERFORMANCE; MRI; UK;
D O I
10.2214/AJR.17.19036
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study is to provide a more accurate estimation of the radiation dose of contrast-enhanced spectral mammography (CESM) relative to that of 2D digital mammography and tomosynthesis using phantom and patient data and an accepted dosimetry protocol that eliminates vendor-specific average glandular dose (AGD) estimates while including breast density. MATERIALS AND METHODS. Patient and phantom AGD estimation was performed using two vendors (system 1 and system 2) in five imaging modes, including 2D, 3D, and CESM imaging. Patient AGD was retrospectively estimated from 45 patients who underwent mammography with all imaging modes during 2012-2016. Patient and phantom AGD were estimated using accepted European and International Atomic Energy Agency protocols for dosimetry and were compared across imaging modes using a paired t test with Bonferroni correction. RESULTS. Phantom data showed that the imaging modes with the lowest to highest AGDs were system 1 2D, followed by system 2 2D and system 2 3D, which had comparable values (p = 0.6), followed by system 1 CESM, and then by system 2 2D plus 3D. One hundred eighty views in 45 patients showed that the system 1 CESM AGD was 1.8 times greater than the system 1 21) AU) (p < 0.001), 1.2 times greater than the system 2 21) AO) (p < 0.001), 1.2 times greater than the system 2 3D AGD (p < 0.001), and 0.6 times less than the system 2 2D plus 3D AGD (p < 0.001). CONCLUSION. The CESM dose for system 1 is within an acceptable range as compared with other commonly performed mammographic examinations and should not preclude its use as a diagnostic breast imaging tool.
引用
收藏
页码:839 / 846
页数:8
相关论文
共 50 条
  • [1] A new breast phantom suitable for digital mammography, contrast-enhanced digital mammography and digital breast tomosynthesis
    Zhang, Changsheng
    Fu, Jian
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (04):
  • [2] Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography
    Felix Diekmann
    Ulrich Bick
    [J]. European Radiology, 2007, 17 : 3086 - 3092
  • [3] Advanced applications of digital mammography: Tomosynthesis and contrast-enhanced digital mammography
    Lewin, John M.
    Niklason, Loren
    [J]. SEMINARS IN ROENTGENOLOGY, 2007, 42 (04) : 243 - 252
  • [4] Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography
    Diekmann, Felix
    Bick, Ulrich
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (12) : 3086 - 3092
  • [5] Comparative Evaluation of Contrast-Enhanced Spectral Mammography and Digital Breast Tomosynthesis for Diagnosing and Treating Breast Cancer
    Yang, Di
    Gong, Fei
    [J]. MEDICAL SCIENCE MONITOR, 2023, 29
  • [6] PERFORMANCE COMPARISON OF SYSTEMS WITH FULL-FIELD DIGITAL MAMMOGRAPHY, DIGITAL BREAST TOMOSYNTHESIS AND CONTRAST-ENHANCED SPECTRAL MAMMOGRAPHY
    Avramova-Cholakova, Simona
    Kulama, Eugenia
    Daskalov, Sivo
    Loveland, John
    [J]. RADIATION PROTECTION DOSIMETRY, 2021, 197 (3-4) : 212 - 229
  • [7] Breast tomosynthesis and contrast-enhanced digital mammography: Competitiveness or complementary?
    Valfort, Alix
    Jalaguier-Coudray, Aurelie
    Villard-Mahjoub, Rim
    [J]. IMAGERIE DE LA FEMME, 2019, 29 (01) : 4 - 7
  • [8] Contrast-enhanced spectral mammography (CESM)
    James, J. J.
    Tennant, S. L.
    [J]. CLINICAL RADIOLOGY, 2018, 73 (08) : 715 - 723
  • [9] Comparison of contrast-enhanced digital mammography and contrast-enhanced digital breast tomosynthesis for lesion assessment Comparison of contrast-enhanced
    Huang, Hailiang
    Scaduto, David A.
    Liu, Chunling
    Yang, Jie
    Zhu, Chencan
    Rinaldi, Kim
    Eisenberg, Jason
    Liu, Jingxuan
    Hoernig, Mathias
    Wicklein, Julia
    Vogt, Sebastian
    Mertelmeier, Thomas
    Fisher, Paul R.
    Zhao, Wei
    [J]. JOURNAL OF MEDICAL IMAGING, 2019, 6 (03)
  • [10] Single Center Evaluation of Comparative Breast Radiation dose of Contrast Enhanced Digital Mammography (CEDM), Digital Mammography (DM) and Digital Breast Tomosynthesis (DBT)
    Bicchierai, Giulia
    Busoni, Simone
    Tortoli, Paolo
    Bettarini, Silvia
    Di Naro, Federica
    De Benedetto, Diego
    Savi, Elena
    Bellini, Chiara
    Miele, Vittorio
    Nori, Jacopo
    [J]. ACADEMIC RADIOLOGY, 2022, 29 (09) : 1342 - 1349