Automated function imaging: a new operator-independent strain method for assessing left ventricular function

被引:100
|
作者
Belghiti, H. [1 ]
Brette, S. [1 ]
Lafitte, S. [1 ]
Reant, P. [1 ]
Picard, F. [1 ]
Serri, K. [1 ]
Lafitte, M. [1 ]
Courregelongue, M. [1 ]
Dos Santos, P. [1 ]
Douard, H. [1 ]
Roudaut, R. [1 ]
DeMaria, A. [2 ]
机构
[1] Hop Cardiol Haut Leveque, Dept Cardiol Chirug, F-33600 Pessac, France
[2] Univ Calif San Diego, San Diego, CA 92103 USA
关键词
speckle tracking; regional left; ventricular function; strain; AFI;
D O I
10.1016/S1875-2136(08)71798-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - Speckle tracking is a new technique based on pure 2D grayscale ultrasound acquisition allowing calculation of segmental strains. To facilitate clinical application, speckle tracking has been integrated into the most recent echocardiographic systems for quick, automated evaluation of left ventricular function (Automated Function Imaging, AFI). Objective. - To evaluate the feasibility, calculation time, accuracy and reproducibility of global longitudinal strain (GLS) from AFI in determining LV function in comparison to reference echocardiographic and angiographic methods-whatever the operator's experience. Methods. - Echocardiography was performed in 65 patients scheduled for cardiac catheterization using a Vivid 7 system. They were divided into 3 groups according to EF (> 55%, 35sEFS55%, < 35%). Image quality, global LV function parameters (ejection fraction, aortic flow, dp/dt) and segmental contraction were analyzed by one experienced operator and one beginner. GLS was obtained from apical 2, 3 and 4 chamber views. GLS was compared to both echocardiographic and angiographic EF, as well as to other echocardiographic parameters. Results. - GLS was obtained successfully in 97% of patients. Mean calculation time including correction of endocardial. detection was less than 60 seconds. GLS was significantly different between the 3 groups, respectively -18.1 +/- 2.5 %, -11.5 +/- 2.1% and -6.0 +/- 1.2% (p < 0.01). Strong correlations were observed between GLS and LV function (r from 0.68 to 0.87) with a high level of reproducibility. No difference was observed between experienced and inexperienced operators. Conclusion. - AFI is clinically applicable and an effective means of assessing LV function due to its short acquisition time, feasibility and accuracy, whatever the experience of the operator. (c) 2008 Published by Elsevier Masson SAS.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 50 条
  • [21] Strain Echocardiography The New Gold Standard for Imaging Ventricular Function?
    Januzzi, James L., Jr.
    Chandrashekhar, Y.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (08) : 955 - 957
  • [22] Correlation of Automated Function Imaging (AFI) to Conventional Strain Analyses of Regional and Global Right Ventricular Function
    Calleja, Anna M.
    Jiamsripong, Panupong
    Alharthi, Mohsen S.
    Cha, Stephen
    Cho, Eun Joo
    McMahon, Eileen M.
    Mookadam, Farouk
    Khandheria, Bijoy K.
    Belohlavek, Marek
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (09) : 1031 - 1039
  • [23] Load-independent indices of left ventricular function using automated border detection
    Gorcsan, J
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1999, 16 (01): : 63 - 76
  • [24] Reduced right ventricular longitudinal strain in patients with preserved right ventricular function and left ventricular dysfunction: a study using conventional and strain imaging method
    Ridjab, D.
    Buddecke, J.
    Manegold, J.
    Tschishow, W.
    Israel, C.
    EUROPEAN HEART JOURNAL, 2012, 33 : 477 - 477
  • [25] New echocardiographic applications for assessing global left ventricular diastolic function
    Claessens, Tom E.
    De Sutter, Johan
    Vanhercke, Daniel
    Segers, Patrick
    Verdonck, Pascal R.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (06): : 823 - 841
  • [26] Noninvasive operator-independent estimation of the vasomotor endothelial function by impedancemetry as possible surrogate marker of the atherosclerosis
    Shantsila, E.
    Polonetsky, L.
    Polonetsky, O.
    Lakchanko, L.
    Latyshev, S.
    Gul, L.
    EUROPEAN HEART JOURNAL, 2007, 28 : 709 - 709
  • [27] Global Left Ventricular Longitudinal Strain Assessed with Automated Function Imaging after Acute Myocardial Infarction Reflects Infarct Size and Predicts Long-Term Recovery of Left Ventricular Function
    Mollema, Sjoerd A.
    Delgado, Victoria
    Berlini, Matteo
    Boersma, Eric
    Holman, Eduard R.
    Van der Wall, Ernst E.
    Schalij, Martin J.
    Bax, Jeroen J.
    CIRCULATION, 2008, 118 (18) : S606 - S606
  • [28] Diagnostic Value of Segmental Longitudinal Strain by Automated Function Imaging in Coronary Artery Disease without Left Ventricular Dysfunction
    Tsai, Wei-Chuan
    Liu, Yen-Wen
    Huang, Yao-Yi
    Lin, Chih-Chan
    Lee, Cheng-Han
    Tsai, Liang-Miin
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (11) : 1183 - 1189
  • [29] Operator independent left ventricular function monitoring during pharmacological stress echo with the new peak transcutaneous acceleration signal
    Bombardini, T
    Marcelli, E
    Picano, E
    Borghi, B
    Fedriga, P
    Garberoglio, B
    Gaggini, G
    Plicchi, G
    HEART, 2001, 85 (03) : 286 - 289
  • [30] Evaluation of left ventricular function with strain/strain rate imaging in patients with rheumatic mitral stenosis
    Simsek, Ziya
    Karakelleoglu, Sule
    Gundogdu, Fuat
    Aksakal, Enbiya
    Sevimli, Serdar
    Arslan, Sakir
    Gurlertop, Yekta
    Senocak, Hueseyin
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2010, 10 (04): : 328 - 333