Automated function imaging: a new operator-independent strain method for assessing left ventricular function

被引:100
|
作者
Belghiti, H. [1 ]
Brette, S. [1 ]
Lafitte, S. [1 ]
Reant, P. [1 ]
Picard, F. [1 ]
Serri, K. [1 ]
Lafitte, M. [1 ]
Courregelongue, M. [1 ]
Dos Santos, P. [1 ]
Douard, H. [1 ]
Roudaut, R. [1 ]
DeMaria, A. [2 ]
机构
[1] Hop Cardiol Haut Leveque, Dept Cardiol Chirug, F-33600 Pessac, France
[2] Univ Calif San Diego, San Diego, CA 92103 USA
关键词
speckle tracking; regional left; ventricular function; strain; AFI;
D O I
10.1016/S1875-2136(08)71798-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - Speckle tracking is a new technique based on pure 2D grayscale ultrasound acquisition allowing calculation of segmental strains. To facilitate clinical application, speckle tracking has been integrated into the most recent echocardiographic systems for quick, automated evaluation of left ventricular function (Automated Function Imaging, AFI). Objective. - To evaluate the feasibility, calculation time, accuracy and reproducibility of global longitudinal strain (GLS) from AFI in determining LV function in comparison to reference echocardiographic and angiographic methods-whatever the operator's experience. Methods. - Echocardiography was performed in 65 patients scheduled for cardiac catheterization using a Vivid 7 system. They were divided into 3 groups according to EF (> 55%, 35sEFS55%, < 35%). Image quality, global LV function parameters (ejection fraction, aortic flow, dp/dt) and segmental contraction were analyzed by one experienced operator and one beginner. GLS was obtained from apical 2, 3 and 4 chamber views. GLS was compared to both echocardiographic and angiographic EF, as well as to other echocardiographic parameters. Results. - GLS was obtained successfully in 97% of patients. Mean calculation time including correction of endocardial. detection was less than 60 seconds. GLS was significantly different between the 3 groups, respectively -18.1 +/- 2.5 %, -11.5 +/- 2.1% and -6.0 +/- 1.2% (p < 0.01). Strong correlations were observed between GLS and LV function (r from 0.68 to 0.87) with a high level of reproducibility. No difference was observed between experienced and inexperienced operators. Conclusion. - AFI is clinically applicable and an effective means of assessing LV function due to its short acquisition time, feasibility and accuracy, whatever the experience of the operator. (c) 2008 Published by Elsevier Masson SAS.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 50 条
  • [41] Accuracy of automated quantitation of left and right ventricular function and volumes by magnetic resonance imaging
    Tan, RS
    Keng, F
    Koh, TH
    Chua, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 411A - 411A
  • [42] Do left atrial strain and strain rate reflect intrinsic atrial function, or are they determined by left ventricular function?
    Margulescu, Andrei Dumitru
    Rees, Emma
    Coulson, Rose-Marie
    Rees, Aled D.
    Vinereanu, Dragos
    Fraser, Alan G.
    KARDIOLOGIA POLSKA, 2015, 73 (07) : 539 - 548
  • [43] Strain-encoded cardiac magnetic resonance imaging: a new approach for fast estimation of left ventricular function
    Tomas Lapinskas
    Victoria Zieschang
    Jennifer Erley
    Lukas Stoiber
    Bernhard Schnackenburg
    Christian Stehning
    Rolf Gebker
    Amit R. Patel
    Keigo Kawaji
    Henning Steen
    Remigijus Zaliunas
    Sören J. Backhaus
    Andreas Schuster
    Marcus Makowski
    Sorin Giusca
    Grigorious Korosoglou
    Burkert Pieske
    Sebastian Kelle
    BMC Cardiovascular Disorders, 19
  • [44] Strain-encoded cardiac magnetic resonance imaging: a new approach for fast estimation of left ventricular function
    Lapinskas, Tomas
    Zieschang, Victoria
    Erley, Jennifer
    Stoiber, Lukas
    Schnackenburg, Bernhard
    Stehning, Christian
    Gebker, Rolf
    Patel, Amit R.
    Kawaji, Keigo
    Steen, Henning
    Zaliunas, Remigijus
    Backhaus, Soeren J.
    Schuster, Andreas
    Makowski, Marcus
    Giusca, Sorin
    Korosoglou, Grigorious
    Pieske, Burkert
    Kelle, Sebastian
    BMC CARDIOVASCULAR DISORDERS, 2019, 19 (1)
  • [45] 1100 Phase contrast imaging: a novel way of assessing left ventricular diastolic function
    Rahul Kumar
    Gary R McNeal
    Kelley C Stewart
    John J Charonko
    Olga Pierrakos
    Pavlos P Vlachos
    William O Ntim
    Gregory Hundley
    Craig A Hamilton
    William C Little
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [46] Two-dimensional strain measures of left ventricular systolic function: new independent predictors of heart failure worsening
    Iacoviello, M.
    Catanzaro, R.
    Puzzovivo, A.
    Monitillo, F.
    Lattarulo, S.
    Marangelli, V.
    Forleo, C.
    Favale, S.
    EUROPEAN HEART JOURNAL, 2011, 32 : 949 - 950
  • [47] Is torsion a novel independent parameter of left ventricular function?
    Uznanska, B.
    Chrzanowski, L.
    Plewka, M.
    Lipiec, P.
    Drozdz, J.
    Krzeminska-Pakula, M.
    Kasprzak, J. D.
    EUROPEAN HEART JOURNAL, 2007, 28 : 886 - 886
  • [48] Relation Between Global Left Ventricular Longitudinal Strain Assessed with Novel Automated Function Imaging and Biplane Left Ventricular Ejection Fraction in Patients with Coronary Artery Disease
    Delgado, Victoria
    Mollema, Sjoerd A.
    Ypenburg, Claudia
    Tops, Laurens F.
    van der Wall, Ernst E.
    Schalij, Martin J.
    Bax, Jeroen J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (11) : 1244 - 1250
  • [49] Usefulness of right ventricular tissue Doppler imaging to predict outcome in left ventricular heart failure independent of left ventricular diastolic function
    Dokainish, Hisham
    Sengupta, Ranjita
    Patel, Rajnikant
    Lakkis, Nasser
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (07): : 961 - 965
  • [50] Measuring longitudinal left ventricular function and strain using cardiovascular magnetic resonance imaging
    Farzaneh-Far, Afshin
    Romano, Simone