Automated function imaging: a new operator-independent strain method for assessing left ventricular function

被引:100
|
作者
Belghiti, H. [1 ]
Brette, S. [1 ]
Lafitte, S. [1 ]
Reant, P. [1 ]
Picard, F. [1 ]
Serri, K. [1 ]
Lafitte, M. [1 ]
Courregelongue, M. [1 ]
Dos Santos, P. [1 ]
Douard, H. [1 ]
Roudaut, R. [1 ]
DeMaria, A. [2 ]
机构
[1] Hop Cardiol Haut Leveque, Dept Cardiol Chirug, F-33600 Pessac, France
[2] Univ Calif San Diego, San Diego, CA 92103 USA
关键词
speckle tracking; regional left; ventricular function; strain; AFI;
D O I
10.1016/S1875-2136(08)71798-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - Speckle tracking is a new technique based on pure 2D grayscale ultrasound acquisition allowing calculation of segmental strains. To facilitate clinical application, speckle tracking has been integrated into the most recent echocardiographic systems for quick, automated evaluation of left ventricular function (Automated Function Imaging, AFI). Objective. - To evaluate the feasibility, calculation time, accuracy and reproducibility of global longitudinal strain (GLS) from AFI in determining LV function in comparison to reference echocardiographic and angiographic methods-whatever the operator's experience. Methods. - Echocardiography was performed in 65 patients scheduled for cardiac catheterization using a Vivid 7 system. They were divided into 3 groups according to EF (> 55%, 35sEFS55%, < 35%). Image quality, global LV function parameters (ejection fraction, aortic flow, dp/dt) and segmental contraction were analyzed by one experienced operator and one beginner. GLS was obtained from apical 2, 3 and 4 chamber views. GLS was compared to both echocardiographic and angiographic EF, as well as to other echocardiographic parameters. Results. - GLS was obtained successfully in 97% of patients. Mean calculation time including correction of endocardial. detection was less than 60 seconds. GLS was significantly different between the 3 groups, respectively -18.1 +/- 2.5 %, -11.5 +/- 2.1% and -6.0 +/- 1.2% (p < 0.01). Strong correlations were observed between GLS and LV function (r from 0.68 to 0.87) with a high level of reproducibility. No difference was observed between experienced and inexperienced operators. Conclusion. - AFI is clinically applicable and an effective means of assessing LV function due to its short acquisition time, feasibility and accuracy, whatever the experience of the operator. (c) 2008 Published by Elsevier Masson SAS.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 50 条
  • [31] Do left atrial strain measurements provide information independent from left ventricular function parameters?
    Malaescu, G. G.
    Petrescu, A.
    Duchenne, J.
    Capota, R.
    Voigt, J. U.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1425 - 1425
  • [32] An automated, operator-independent method for quantitative analysis of florbetaben PET scans to assist in the differential diagnosis of dementia
    Zubal, George
    Barret, Olivier
    Wisniewski, Gary
    Reininger, Cornelia
    Barthel, Henryk
    Pessel, Martin
    Sabri, Osama
    Seibyl, John
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [33] A new perspective on an old method: gated SPECT imaging for left ventricular contractile function assessment
    San Miguel, Lucas
    Goldschmidt, Ezequiel
    Brisbin, Alyssa K.
    Redruello, Marcela
    Masoli, Osvaldo H.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (06) : 2658 - 2665
  • [34] A new perspective on an old method: gated SPECT imaging for left ventricular contractile function assessment
    Lucas San Miguel
    Ezequiel Goldschmidt
    Alyssa K. Brisbin
    Marcela Redruello
    Osvaldo H. Masoli
    Journal of Nuclear Cardiology, 2023, 30 : 2658 - 2665
  • [35] Evaluation of subclinical left ventricular systolic dysfunction in patents with obstructive sleep apnea by automated function imaging method
    Altekin, E.
    Yanikoglu, A.
    Karakas, S.
    Ozel, D.
    Yildirim, A. Belgi
    Kabukcu, M.
    EUROPEAN HEART JOURNAL, 2012, 33 : 481 - 481
  • [36] Left ventricular function in professional football players evaluated by tissue Doppler imaging and strain imaging
    Tumuklu, Mustafa Murat
    Etikan, Ilker
    Cinar, Cahide Soydas
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (01): : 25 - 35
  • [37] Left ventricular function in professional football players evaluated by tissue Doppler imaging and strain imaging
    Mustafa Murat Tümüklü
    Ilker Etikan
    Cahide Soydaş Çinar
    The International Journal of Cardiovascular Imaging, 2008, 24 : 25 - 35
  • [38] Correlation of Left Ventricular Pressure Changes and Left Atrial Function on Strain Rate Imaging During Acute Left Ventricular Ischemia
    Mu, Yu-ming
    Kasamaki, Yuji
    Ozawa, Yukio
    Ohta, Masakatsu
    Chen, Xiao-feng
    Tang, Qi
    Wang, Chun-mei
    Hirayama, Atsushi
    INTERNATIONAL HEART JOURNAL, 2010, 51 (06) : 421 - 425
  • [39] Right ventricular strain imaging: An emerging method to quantify right ventricular systolic function
    Hesse, B
    Sun, JP
    Garcia, M
    Asher, CR
    CIRCULATION, 2003, 108 (17) : 553 - 554
  • [40] Myocardial strain rate is a superior method for evaluation of left ventricular subendocardial function compared with tissue doppler imaging
    Hashimoto, I
    Li, XK
    Bhat, AH
    Jones, M
    Zetts, AD
    Sahn, DJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (09) : 1574 - 1583