Operator independent left ventricular function monitoring during pharmacological stress echo with the new peak transcutaneous acceleration signal

被引:7
|
作者
Bombardini, T [1 ]
Marcelli, E
Picano, E
Borghi, B
Fedriga, P
Garberoglio, B
Gaggini, G
Plicchi, G
机构
[1] Univ Bologna, Biomed Technol Dept, Bologna, Italy
[2] CNR, IFC, I-56100 Pisa, Italy
[3] IRCCS Rizzoli, Bologna, Italy
[4] Sorin Biomed Cardio, Saluggia, Italy
关键词
ventricular function; contractility; peak endocardial acceleration; stress echo;
D O I
10.1136/heart.85.3.286
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-As the myocardium contracts isometrically, it generates vibrations that can be measured with an accelerometer. The vibration peak, peak endocardial acceleration (PEA), is an index of contractility. Objective-To evaluate the feasibility of PEA measured by the cutaneous precordial application of the accelerometer sensor; and to assess the usefulness of PEA monitoring during pharmacological stress echocardiography. Design-Feasibility study. Setting-Stress echo laboratory. Patients-34 consecutive patients underwent pharmacological stress (26 with dipyridamole; 8 with dobutamine) and PEA monitoring simultaneously. Interventions-A microaccelerometer was positioned in the precordial region and PEA was recorded. Dipyridamole was infused up to 0.84 mg/kg in 10 minutes, and dobutamine up to 40 mug/kg/min in 15 minutes. Results-A consistent PEA signal was obtained in all patients. Overall mean (SD) baseline PEA was 0.26 (0.15) g (g = 9.8 m/s(2)), increasing to 0.5 (0.36) g at peak stress (+0.24 g, 95% confidence interval (CI) 0.14 to 0.34 g; p < 0.01). PEA increased from 0.26 (0.16) to 0.37 (0.25) g in the dipyridamole group (+0.11 g, 95% CI 0.08 to 0.16 g; p < 0.01), and from 0.29 (0.1) to 0.93 (0.37) g in the dobutamine group (+0.64 g, 95% CI 0.37 to 0.91 g; p < 0.01). Conclusions-Using precordial leads this method offers potential for diagnostic application in the short term monitoring of myocardial function. PEA monitoring is feasible during pharmacological stress and documents left ventricular inotropic response quantitatively in a non-invasive and operator independent fashion.
引用
收藏
页码:286 / 289
页数:4
相关论文
共 8 条
  • [1] Operator-Independent Force-Frequency Relation Monitoring during Stress with a New Transcutaneous Cardiac Force Sensor
    Gemignani, V.
    Bianchini, E.
    Faita, F.
    Giannoni, M.
    Pasanisi, E.
    Picano, E.
    Bombardini, T.
    COMPUTERS IN CARDIOLOGY 2007, VOL 34, 2007, 34 : 737 - 740
  • [2] Automated function imaging: a new operator-independent strain method for assessing left ventricular function
    Belghiti, H.
    Brette, S.
    Lafitte, S.
    Reant, P.
    Picard, F.
    Serri, K.
    Lafitte, M.
    Courregelongue, M.
    Dos Santos, P.
    Douard, H.
    Roudaut, R.
    DeMaria, A.
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2008, 101 (03) : 163 - 169
  • [3] Quantitation of regional left ventricular function during dobutamine echo using tissue Doppler is independent of image quality
    Cain, P
    Chan, J
    Short, L
    Wahi, S
    Marwick, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 490A - 490A
  • [4] DOPPLER ECHO OF ASCENDING AORTIC BLOOD-FLOW ACCELERATION DURING EXERCISE - A MEASURE OF LEFT-VENTRICULAR FUNCTION
    CHRISTIE, JL
    WANN, LS
    SHELDAHL, LM
    TRISTANI, FE
    SAGAR, KB
    WOLF, L
    CLINICAL RESEARCH, 1986, 34 (02): : A290 - A290
  • [5] PEAK CAROTID FLOW ACCELERATION - POSSIBLE INDEX OF LEFT-VENTRICULAR FUNCTION DURING ACUTE MYOCARDIAL ISCHEMIA AND INFARCTION
    GAMS, E
    HUNTSMAN, LL
    CHIMOSKE.JE
    EUROPEAN SURGICAL RESEARCH, 1974, 6 : 70 - 70
  • [6] INFLUENCE OF LEFT-VENTRICULAR SYSTOLIC FUNCTION ON MITRAL DOPPLER FLOW PATTERN DURING DOBUTAMINE ECHO STRESS TEST
    ESQUIVEL, JG
    BLALOCK, W
    COCHRAN, T
    REYES, B
    AHMAD, M
    CLINICAL RESEARCH, 1993, 41 (04): : A722 - A722
  • [7] Force-frequency relationship during dobutamine-stress echo: non-invasive exercise-independent assessment of left-ventricular contractility in the echo lab
    Grosu, A
    Bombardini, T
    Senni, M
    Pasanisi, E
    Sicari, R
    Venneri, L
    Picano, E
    EUROPEAN HEART JOURNAL, 2003, 24 : 253 - 253
  • [8] Use of peak systolic strain as an index of regional left ventricular function: Comparison with tissue Doppler velocity during dobutamine stress and myocardial ischemia
    Armstrong, G
    Pasquet, A
    Fukamachi, K
    Cardon, L
    Olstad, B
    Marwick, T
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (08) : 731 - 737