Automated function imaging: a new operator-independent strain method for assessing left ventricular function

被引:100
|
作者
Belghiti, H. [1 ]
Brette, S. [1 ]
Lafitte, S. [1 ]
Reant, P. [1 ]
Picard, F. [1 ]
Serri, K. [1 ]
Lafitte, M. [1 ]
Courregelongue, M. [1 ]
Dos Santos, P. [1 ]
Douard, H. [1 ]
Roudaut, R. [1 ]
DeMaria, A. [2 ]
机构
[1] Hop Cardiol Haut Leveque, Dept Cardiol Chirug, F-33600 Pessac, France
[2] Univ Calif San Diego, San Diego, CA 92103 USA
关键词
speckle tracking; regional left; ventricular function; strain; AFI;
D O I
10.1016/S1875-2136(08)71798-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - Speckle tracking is a new technique based on pure 2D grayscale ultrasound acquisition allowing calculation of segmental strains. To facilitate clinical application, speckle tracking has been integrated into the most recent echocardiographic systems for quick, automated evaluation of left ventricular function (Automated Function Imaging, AFI). Objective. - To evaluate the feasibility, calculation time, accuracy and reproducibility of global longitudinal strain (GLS) from AFI in determining LV function in comparison to reference echocardiographic and angiographic methods-whatever the operator's experience. Methods. - Echocardiography was performed in 65 patients scheduled for cardiac catheterization using a Vivid 7 system. They were divided into 3 groups according to EF (> 55%, 35sEFS55%, < 35%). Image quality, global LV function parameters (ejection fraction, aortic flow, dp/dt) and segmental contraction were analyzed by one experienced operator and one beginner. GLS was obtained from apical 2, 3 and 4 chamber views. GLS was compared to both echocardiographic and angiographic EF, as well as to other echocardiographic parameters. Results. - GLS was obtained successfully in 97% of patients. Mean calculation time including correction of endocardial. detection was less than 60 seconds. GLS was significantly different between the 3 groups, respectively -18.1 +/- 2.5 %, -11.5 +/- 2.1% and -6.0 +/- 1.2% (p < 0.01). Strong correlations were observed between GLS and LV function (r from 0.68 to 0.87) with a high level of reproducibility. No difference was observed between experienced and inexperienced operators. Conclusion. - AFI is clinically applicable and an effective means of assessing LV function due to its short acquisition time, feasibility and accuracy, whatever the experience of the operator. (c) 2008 Published by Elsevier Masson SAS.
引用
收藏
页码:163 / 169
页数:7
相关论文
共 50 条
  • [1] A NOVEL OPERATOR-INDEPENDENT NONINVASIVE DEVICE FOR ASSESSING VASCULAR ENDOTHELIAL FUNCTION
    Knowles, Kellen
    Stewart, Kerry
    Ouyang, Pamela
    Ratchford, Elizabeth
    Sullam, Laura
    Silber, Harry
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1991 - 1991
  • [2] Automated function imaging - evaluation of the clinical feasibility for assessing left ventricular deformation
    Niemann, M.
    Niemann, H.
    Strotmann, J.
    Herrmann, S.
    Weidemann, F.
    EUROPEAN HEART JOURNAL, 2009, 30 : 945 - 945
  • [3] Automated function imaging to assess left ventricular systolic function: relation between global left ventricular longitudinal strain and biplane left ventricular ejection fraction
    Delgado, V.
    Mollema, S. A.
    Tops, L. F.
    Ypenburg, C.
    Marsan, N. Ajmone
    Van der Wall, E. E.
    Schalij, M. J.
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2008, 29 : 253 - 253
  • [4] Automated Function Imaging (AFI)-derived strain rate evaluation of left ventricular relaxation
    Savioli, G.
    Guglielmo, M.
    Cefalu', C.
    Mirea, O.
    Barbier, P.
    EUROPEAN HEART JOURNAL, 2014, 35 : 959 - 960
  • [5] Strain rate imaging offers new insights into left ventricular diastolic function
    Voigt, JU
    Lindenmeier, G
    Cubra, A
    Werner, D
    Sutherland, GR
    Hatle, U
    Nixdorff, U
    Flachskampf, FA
    Daniel, WG
    CIRCULATION, 2000, 102 (18) : 537 - 537
  • [6] Applicability of Automated Functional Imaging for Assessing Right Ventricular Function
    Lopez-Candales, Angel
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (08): : 919 - 928
  • [7] LEFT-VENTRICULAR WALL MOTION ANALYSIS USING OPERATOR-INDEPENDENT CONTOUR POSITIONING
    SANDOR, T
    PAULIN, S
    HANLON, WB
    COMPUTERS AND BIOMEDICAL RESEARCH, 1984, 17 (02): : 129 - 142
  • [8] Automated quantification of left ventricular function by the automated contour tracking method
    Sugioka, K
    Hozumi, T
    Yagi, T
    Yamamuro, A
    Akasaka, T
    Takeuchi, K
    Homma, S
    Yoshida, K
    Yoshikawa, J
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2003, 20 (04): : 313 - 318
  • [9] Does strain rate imaging offer new insights into left ventricular diastolic function?
    Voigt, JU
    Lindenmeier, G
    Cubra, A
    Werner, D
    Flachskampf, FA
    Hatle, L
    Sutherland, GR
    Daniel, WG
    EUROPEAN HEART JOURNAL, 2000, 21 : 334 - 334
  • [10] Left ventricular function assessment in Kawasaki disease by two-dimensional global longitudinal systolic strain with automated function imaging
    Moghadam, Ehsan Aghaei
    Taraz, Maryam
    Zeinaloo, Aliakbar
    Majnoon, Mohammad Taghi
    Zanjani, Keyhan Sayadpour
    Gorgi, Mojtaba
    EGYPTIAN HEART JOURNAL, 2024, 76 (01):