Cardiac spiral dual-source CT with high pitch: a feasibility study

被引:53
|
作者
Ertel, Dirk [1 ]
Lell, Michael M. [2 ]
Harig, Frank [3 ]
Flohr, Thomas [4 ]
Schmidt, Bernhard [4 ]
Kalender, Willi A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Radiol, D-91052 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Ctr Cardiac Surg, D-91052 Erlangen, Germany
[4] Siemens Healthcare, Forchheim, Germany
关键词
Dual-source CT; Cardiac imaging; Image quality; Dose; High pitch; TOMOGRAPHY CORONARY-ANGIOGRAPHY; MULTISLICE COMPUTED-TOMOGRAPHY; IMAGE QUALITY; RADIATION-EXPOSURE; SHOOT MODE; PERFORMANCE; HEART; VALIDATION; MODULATION; REDUCTION;
D O I
10.1007/s00330-009-1503-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Increase of pitch in spiral CT decreases data acquisition time; dual-source CT (DSCT) systems provide improved temporal resolution. We evaluated the combination of these two features. Measurements were performed using a commercial DSCT system equipped with prototype software allowing pitch factors from p=0.35 to 3.0. We measured slice sensitivity profiles as a function of pitch to assess spatial resolution in the z-direction and the contrast of structures moved periodically to measure temporal resolution. Additionally we derived modulation transfer functions to provide objective parameters; both spatial and temporal resolution were essentially unchanged even at high pitch. CT of the cardiac region of three pigs was performed at p=3.0. In vivo CT images confirmed good image quality; direct comparison with standard low-pitch phase-correlated CT image datasets showed no significant difference. For a normalized z-axis acquisition of 12 cm, the corresponding effective dose value was 2.0 mSv for the high-pitch CT protocol. We conclude that spiral DSCT imaging with a pitch of 3.0 can provide unimpaired image quality with respect to spatial and temporal resolution. Applications to cardiac and thoracic imaging with effective dose below 1 mSv are possible.
引用
收藏
页码:2357 / 2362
页数:6
相关论文
共 50 条
  • [31] Is ECG triggering for motion artefact reduction in dual-source CT angiography of the ascending aorta still required with high-pitch scanning? The role of ECG-gating in high-pitch dual-source CT of the ascending aorta
    Wielandner, Alice
    Beitzke, Dietrich
    Schernthaner, Ruediger
    Wolf, Florian
    Langenberger, Christina
    Stadler, Alfred
    Loewe, Christian
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1064):
  • [32] High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates
    Goetti, Robert
    Feuchtner, Gudrun
    Stolzmann, Paul
    Desbiolles, Lotus
    Fischer, Michael Alexander
    Karlo, Christoph
    Baumueller, Stephan
    Scheffel, Hans
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2010, 20 (11) : 2565 - 2571
  • [33] Multi-slice and Dual-source CT in Cardiac Imaging
    Thali, M.
    KARDIOLOGE, 2008, 2 (04): : 293 - 293
  • [34] Assessment of the Coronary Artery in High-Pitch, Dual-Source CT Aortography Without ECG Synchronization
    Choi, Hyeong Gi
    Park, Mi Jung
    Choi, Ho Cheol
    Choi, Hye Young
    Shin, Hwa Seon
    Na, Jae Boem
    Cho, Jae Min
    Choi, Dae Seob
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (03)
  • [35] Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience
    Sebastian Leschka
    Paul Stolzmann
    Lotus Desbiolles
    Stephan Baumueller
    Robert Goetti
    Thomas Schertler
    Hans Scheffel
    Andre Plass
    Volkmar Falk
    Gudrun Feuchtner
    Borut Marincek
    Hatem Alkadhi
    European Radiology, 2009, 19 : 2896 - 2903
  • [36] Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience
    Leschka, Sebastian
    Stolzmann, Paul
    Desbiolles, Lotus
    Baumueller, Stephan
    Goetti, Robert
    Schertler, Thomas
    Scheffel, Hans
    Plass, Andre
    Falk, Volkmar
    Feuchtner, Gudrun
    Marincek, Borut
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2009, 19 (12) : 2896 - 2903
  • [37] Accuracy of 128-slice dual-source CT using high-pitch spiral mode for the assessment of coronary stents: First in vivo experience
    Yang Xia
    Yang Junjie
    Zhou Ying
    He Bai
    Wang Qi
    Jin Qinhua
    Chen Yundai
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (04) : 617 - 622
  • [38] Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality
    Flohr, Thomas G.
    Leng, Shuai
    Yu, Lifeng
    Allmendinger, Thomas
    Bruder, Herbert
    Petersilka, Martin
    Eusemann, Christian D.
    Stierstorfer, Karl
    Schmidt, Bernhard
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2009, 36 (12) : 5641 - 5653
  • [39] Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
    Zhuang, Y.
    Huang, W.
    Shi, Y.
    Bo, G.
    Lu, D.
    Zhang, J.
    Kong, D.
    Shit, Y.
    Wang, B.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (02): : 225 - 233
  • [40] Preliminary Study: Generation of a Kymogram Function using a Dual-Source Cardiac CT Scanner
    Ertel, D.
    Kachelriess, M.
    Kalender, W. A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1368 - 1371