Cardiac spiral dual-source CT with high pitch: a feasibility study

被引:53
|
作者
Ertel, Dirk [1 ]
Lell, Michael M. [2 ]
Harig, Frank [3 ]
Flohr, Thomas [4 ]
Schmidt, Bernhard [4 ]
Kalender, Willi A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Dept Radiol, D-91052 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Ctr Cardiac Surg, D-91052 Erlangen, Germany
[4] Siemens Healthcare, Forchheim, Germany
关键词
Dual-source CT; Cardiac imaging; Image quality; Dose; High pitch; TOMOGRAPHY CORONARY-ANGIOGRAPHY; MULTISLICE COMPUTED-TOMOGRAPHY; IMAGE QUALITY; RADIATION-EXPOSURE; SHOOT MODE; PERFORMANCE; HEART; VALIDATION; MODULATION; REDUCTION;
D O I
10.1007/s00330-009-1503-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Increase of pitch in spiral CT decreases data acquisition time; dual-source CT (DSCT) systems provide improved temporal resolution. We evaluated the combination of these two features. Measurements were performed using a commercial DSCT system equipped with prototype software allowing pitch factors from p=0.35 to 3.0. We measured slice sensitivity profiles as a function of pitch to assess spatial resolution in the z-direction and the contrast of structures moved periodically to measure temporal resolution. Additionally we derived modulation transfer functions to provide objective parameters; both spatial and temporal resolution were essentially unchanged even at high pitch. CT of the cardiac region of three pigs was performed at p=3.0. In vivo CT images confirmed good image quality; direct comparison with standard low-pitch phase-correlated CT image datasets showed no significant difference. For a normalized z-axis acquisition of 12 cm, the corresponding effective dose value was 2.0 mSv for the high-pitch CT protocol. We conclude that spiral DSCT imaging with a pitch of 3.0 can provide unimpaired image quality with respect to spatial and temporal resolution. Applications to cardiac and thoracic imaging with effective dose below 1 mSv are possible.
引用
收藏
页码:2357 / 2362
页数:6
相关论文
共 50 条
  • [41] Use of High-Pitch Dual-Source Computed Tomography of the Abdomen and Pelvis to Markedly Reduce Scan Time: A Clinical Feasibility Study
    Hardie, Andrew D.
    Mayes, Nicholas
    Boulter, Daniel J.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (03) : 353 - 355
  • [42] Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning
    Bischoff, Bernhard
    Meinel, Felix G.
    Reiser, Maximilian
    Becker, Hans-Christoph
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05): : 1159 - 1165
  • [43] Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning
    Bernhard Bischoff
    Felix G. Meinel
    Maximilian Reiser
    Hans-Christoph Becker
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1159 - 1165
  • [44] Low kVp imaging for dose reduction in dual-source cardiac CT
    Luaces, Maria
    Akers, Scott
    Litt, Harold
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 165 - 175
  • [45] Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience
    Morsbach, Fabian
    Gordic, Sonja
    Desbiolles, Lotus
    Husarik, Daniela
    Frauenfelder, Thomas
    Schmidt, Bernhard
    Allmendinger, Thomas
    Wildermuth, Simon
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1889 - 1895
  • [46] Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience
    Fabian Morsbach
    Sonja Gordic
    Lotus Desbiolles
    Daniela Husarik
    Thomas Frauenfelder
    Bernhard Schmidt
    Thomas Allmendinger
    Simon Wildermuth
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2014, 24 : 1889 - 1895
  • [47] High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    Beeres, Martin
    Schell, Boris
    Mastragelopoulos, Aristidis
    Herrmann, Eva
    Kerl, Josef Matthias
    Gruber-Rouh, Tatjana
    Lee, Clara
    Siebenhandl, Petra
    Bodelle, Boris
    Zangos, Stephan
    Vogl, Thomas J.
    Jacobi, Volkmar
    Bauer, Ralf W.
    EUROPEAN RADIOLOGY, 2012, 22 (01) : 129 - 137
  • [48] High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    Martin Beeres
    Boris Schell
    Aristidis Mastragelopoulos
    Eva Herrmann
    Josef Matthias Kerl
    Tatjana Gruber-Rouh
    Clara Lee
    Petra Siebenhandl
    Boris Bodelle
    Stephan Zangos
    Thomas J. Vogl
    Volkmar Jacobi
    Ralf W. Bauer
    European Radiology, 2012, 22 : 129 - 137
  • [49] Evaluating Low-kV Dual-source CT Angiography by High-pitch Spiral Acquisition and Iterative Reconstruction in Pediatric Congenital Heart Disease Patients
    Marukawa, Yohei
    Sato, Shuhei
    Tanaka, Takashi
    Tada, Akihiro
    Kanie, Yuichiro
    Kanazawa, Susumu
    ACTA MEDICA OKAYAMA, 2017, 71 (05) : 407 - 412
  • [50] Evaluation of high-pitch dual-source CT angiography for evaluation of coronary and carotid-cerebrovascular arteries
    Sun, Kai
    Li, Kuncheng
    Han, Ruijuan
    Li, Wenhuan
    Chen, Nan
    Yang, Qi
    Du, Xiangying
    Wang, Chen
    Liu, Guorong
    Li, Yuechun
    Zhou, Maorong
    Li, Ligang
    Heidrun, Endt
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (03) : 398 - 406