High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates

被引:49
|
作者
Goetti, Robert [2 ]
Feuchtner, Gudrun [2 ]
Stolzmann, Paul [2 ,3 ]
Desbiolles, Lotus [2 ]
Fischer, Michael Alexander [2 ]
Karlo, Christoph [2 ]
Baumueller, Stephan [2 ]
Scheffel, Hans [2 ,3 ]
Alkadhi, Hatem [2 ,3 ]
Leschka, Sebastian [1 ,2 ]
机构
[1] Kantonsspital, Inst Radiol, CH-9007 St Gallen, Switzerland
[2] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[3] Massachusetts Gen Hosp, Cardiac MR PET CT Program, Boston, MA 02114 USA
关键词
High-pitch; Computed tomography; Systolic reconstruction; Coronary arteries; Heart rate; Radiation dose; SOURCE COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; RADIATION-EXPOSURE; IMAGE QUALITY; ROW CT; WINDOWS; AORTA;
D O I
10.1007/s00330-010-1838-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the effect of systolic data acquisition for electrocardiography (ECG)-triggered high-pitch computed tomography (CT) on motion artefacts of coronary arteries in patients with high heart rates (HRs). Eighty consecutive patients (15 women, age 67 +/- 14 years) with HR a parts per thousand yen70 bpm underwent CT angiography of the thoracic aorta (CTA) on 128-slice dual-source CT in ECG-triggered high-pitch acquisition mode (pitch = 3.2) set at 60% (group A, n = 40) or 30% (group B, n = 40) of the RR interval. Two blinded readers graded coronary artery image quality on a three-point scale. Radiation doses were calculated. Inter-observer agreement in grading image quality of the 1,154 coronary segments was good (kappa = 0.62). HRs were similar in groups A and B (85 +/- 13 bpm vs 85 +/- 14 bpm, p not significant). Significantly fewer coronary segments with non-diagnostic image quality occurred (i.e. score 3) in group B than in group A [2.8% (16/579) vs 8.3% (48/575), p < 0.001]. Seventeen patients (42.5%) of group A and 12 patients (30.0%) of group B had at least one non-diagnostic segment. Effective radiation doses were 2.3 +/- 0.3 mSv for chest CTA. A systolic acquisition window for high-pitch dual-source CTA in patients with high HRs (a parts per thousand yen70 bpm) significantly improves coronary artery image quality at a low radiation dose.
引用
收藏
页码:2565 / 2571
页数:7
相关论文
共 50 条
  • [1] High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates
    Robert Goetti
    Gudrun Feuchtner
    Paul Stolzmann
    Lotus Desbiolles
    Michael Alexander Fischer
    Christoph Karlo
    Stephan Baumueller
    Hans Scheffel
    Hatem Alkadhi
    Sebastian Leschka
    [J]. European Radiology, 2010, 20 : 2565 - 2571
  • [2] High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate
    Gordic, Sonja
    Husarik, Daniela B.
    Desbiolles, Lotus
    Leschka, Sebastian
    Frauenfelder, Thomas
    Alkadhi, Hatem
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (06): : 1173 - 1179
  • [3] High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate
    Sonja Gordic
    Daniela B. Husarik
    Lotus Desbiolles
    Sebastian Leschka
    Thomas Frauenfelder
    Hatem Alkadhi
    [J]. The International Journal of Cardiovascular Imaging, 2014, 30 : 1173 - 1179
  • [4] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Lembcke, Alexander
    Schwenke, Carsten
    Hein, Patrick A.
    Knobloch, Gesine
    Durmus, Tahir
    Hamm, Bernd
    Huppertz, Alexander
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (01) : 120 - 127
  • [5] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Alexander Lembcke
    Carsten Schwenke
    Patrick A. Hein
    Gesine Knobloch
    Tahir Durmus
    Bernd Hamm
    Alexander Huppertz
    [J]. European Radiology, 2014, 24 : 120 - 127
  • [6] Electrocardiographically triggered CT angiography of the whole aorta and coronary arteries with high-pitch dual-source CT
    张楠
    [J]. China Medical Abstracts (Internal Medicine), 2013, 30 (02) : 65 - 65
  • [7] High-pitch dual-source CT coronary angiography: analysis of the impact on image quality of altered electrocardiography waves during data acquisition
    Xiaoling Wang
    Jiliang Fang
    Haibin Tong
    Qing Zhao
    Qingqiao Song
    Ping Luo
    Chao Xue
    Min Zhang
    Shuhua Yang
    Qun Wang
    Ping Wang
    Fengxiang Shi
    Lei Xu
    Peijing Rong
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 15 - 20
  • [8] High-pitch dual-source CT coronary angiography: analysis of the impact on image quality of altered electrocardiography waves during data acquisition
    Wang, Xiaoling
    Fang, Jiliang
    Tong, Haibin
    Zhao, Qing
    Song, Qingqiao
    Luo, Ping
    Xue, Chao
    Zhang, Min
    Yang, Shuhua
    Wang, Qun
    Wang, Ping
    Shi, Fengxiang
    Xu, Lei
    Rong, Peijing
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 : 15 - 20
  • [9] High-pitch coronary CT angiography in dual-source CT during free breathing vs. breath holding in patients with low heart rates
    Bischoff, Bernhard
    Meinel, Felix G.
    Del Prete, Alessandra
    Reiser, Maximilian F.
    Becker, Hans-Christoph
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : 2217 - 2221
  • [10] Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study
    Yang, Wen Jie
    Chen, Ke Min
    Liu, Bo
    Pang, Li Fang
    Zhang, Huan
    Pan, Zi Lai
    Yan, Fu Hua
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (01): : 245 - 252