High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates

被引:49
|
作者
Goetti, Robert [2 ]
Feuchtner, Gudrun [2 ]
Stolzmann, Paul [2 ,3 ]
Desbiolles, Lotus [2 ]
Fischer, Michael Alexander [2 ]
Karlo, Christoph [2 ]
Baumueller, Stephan [2 ]
Scheffel, Hans [2 ,3 ]
Alkadhi, Hatem [2 ,3 ]
Leschka, Sebastian [1 ,2 ]
机构
[1] Kantonsspital, Inst Radiol, CH-9007 St Gallen, Switzerland
[2] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[3] Massachusetts Gen Hosp, Cardiac MR PET CT Program, Boston, MA 02114 USA
关键词
High-pitch; Computed tomography; Systolic reconstruction; Coronary arteries; Heart rate; Radiation dose; SOURCE COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; RADIATION-EXPOSURE; IMAGE QUALITY; ROW CT; WINDOWS; AORTA;
D O I
10.1007/s00330-010-1838-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the effect of systolic data acquisition for electrocardiography (ECG)-triggered high-pitch computed tomography (CT) on motion artefacts of coronary arteries in patients with high heart rates (HRs). Eighty consecutive patients (15 women, age 67 +/- 14 years) with HR a parts per thousand yen70 bpm underwent CT angiography of the thoracic aorta (CTA) on 128-slice dual-source CT in ECG-triggered high-pitch acquisition mode (pitch = 3.2) set at 60% (group A, n = 40) or 30% (group B, n = 40) of the RR interval. Two blinded readers graded coronary artery image quality on a three-point scale. Radiation doses were calculated. Inter-observer agreement in grading image quality of the 1,154 coronary segments was good (kappa = 0.62). HRs were similar in groups A and B (85 +/- 13 bpm vs 85 +/- 14 bpm, p not significant). Significantly fewer coronary segments with non-diagnostic image quality occurred (i.e. score 3) in group B than in group A [2.8% (16/579) vs 8.3% (48/575), p < 0.001]. Seventeen patients (42.5%) of group A and 12 patients (30.0%) of group B had at least one non-diagnostic segment. Effective radiation doses were 2.3 +/- 0.3 mSv for chest CTA. A systolic acquisition window for high-pitch dual-source CTA in patients with high HRs (a parts per thousand yen70 bpm) significantly improves coronary artery image quality at a low radiation dose.
引用
下载
收藏
页码:2565 / 2571
页数:7
相关论文
共 50 条
  • [21] Iterative reconstruction improves detection of in-stent restenosis by high-pitch dual-source coronary CT angiography
    Yang, Junjie
    Yang, Xiaobo
    De Cecco, Carlo N.
    Duguay, Taylor M.
    Chen, Zhiye
    Tesche, Christian
    Schoepf, U. Joseph
    Chen, Yundai
    SCIENTIFIC REPORTS, 2017, 7
  • [22] Assessment of aortic annulus dimensions for transcatheter aortic valve replacement (TAVR) with high-pitch dual-source CT: Comparison of systolic high-pitch vs. multiphasic data acquisition
    Capilli, Fabio
    Benndorf, Matthias
    Soschynski, Martin
    Hagar, Muhammad Taha
    Kharabish, Ahmed
    Neumann, Franz-Josef
    Pache, Gregor
    Schlett, Christopher L.
    Bamberg, Fabian
    Krauss, Tobias
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 133
  • [23] Iterative reconstruction improves detection of in-stent restenosis by high-pitch dual-source coronary CT angiography
    Junjie Yang
    Xiaobo Yang
    Carlo N. De Cecco
    Taylor M. Duguay
    Zhiye Chen
    Christian Tesche
    U. Joseph Schoepf
    Yundai Chen
    Scientific Reports, 7
  • [24] High-Pitch Dual-Source CT Angiography of the Thoracic and Abdominal Aorta: Is Simultaneous Coronary Artery Assessment Possible?
    Goetti, Robert
    Baumueller, Stephan
    Feuchtner, Gudrun
    Stolzmann, Paul
    Karlo, Christoph
    Alkadhi, Hatem
    Leschka, Sebastian
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) : 938 - 944
  • [25] Systolic High-Pitch Coronary CT Angiography for Evaluation of the Coronary Arteries in Heart Transplant Recipients
    Bastarrika, Gorka
    Calvo, Marta
    Ezponda, Ana
    Garcia-Baizan, Alejandra
    Caballeros, Meylin
    Rabago, Gregorio
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (04) : 828 - 833
  • [26] Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning
    Bernhard Bischoff
    Felix G. Meinel
    Maximilian Reiser
    Hans-Christoph Becker
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1159 - 1165
  • [27] Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning
    Bischoff, Bernhard
    Meinel, Felix G.
    Reiser, Maximilian
    Becker, Hans-Christoph
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05): : 1159 - 1165
  • [28] Radiation dose and diagnostic accuracy of high-pitch dual-source coronary angiography in the evaluation of coronary artery stenoses
    Koplay, M.
    Erdogan, H.
    Avci, A.
    Sivri, M.
    Demir, K.
    Guler, I.
    Demir, L. S.
    Paksoy, Y.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (04) : 461 - 469
  • [29] Assessment of the Coronary Artery in High-Pitch, Dual-Source CT Aortography Without ECG Synchronization
    Choi, Hyeong Gi
    Park, Mi Jung
    Choi, Ho Cheol
    Choi, Hye Young
    Shin, Hwa Seon
    Na, Jae Boem
    Cho, Jae Min
    Choi, Dae Seob
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (03)
  • [30] Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience
    Sebastian Leschka
    Paul Stolzmann
    Lotus Desbiolles
    Stephan Baumueller
    Robert Goetti
    Thomas Schertler
    Hans Scheffel
    Andre Plass
    Volkmar Falk
    Gudrun Feuchtner
    Borut Marincek
    Hatem Alkadhi
    European Radiology, 2009, 19 : 2896 - 2903