High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates

被引:49
|
作者
Goetti, Robert [2 ]
Feuchtner, Gudrun [2 ]
Stolzmann, Paul [2 ,3 ]
Desbiolles, Lotus [2 ]
Fischer, Michael Alexander [2 ]
Karlo, Christoph [2 ]
Baumueller, Stephan [2 ]
Scheffel, Hans [2 ,3 ]
Alkadhi, Hatem [2 ,3 ]
Leschka, Sebastian [1 ,2 ]
机构
[1] Kantonsspital, Inst Radiol, CH-9007 St Gallen, Switzerland
[2] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[3] Massachusetts Gen Hosp, Cardiac MR PET CT Program, Boston, MA 02114 USA
关键词
High-pitch; Computed tomography; Systolic reconstruction; Coronary arteries; Heart rate; Radiation dose; SOURCE COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; RADIATION-EXPOSURE; IMAGE QUALITY; ROW CT; WINDOWS; AORTA;
D O I
10.1007/s00330-010-1838-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the effect of systolic data acquisition for electrocardiography (ECG)-triggered high-pitch computed tomography (CT) on motion artefacts of coronary arteries in patients with high heart rates (HRs). Eighty consecutive patients (15 women, age 67 +/- 14 years) with HR a parts per thousand yen70 bpm underwent CT angiography of the thoracic aorta (CTA) on 128-slice dual-source CT in ECG-triggered high-pitch acquisition mode (pitch = 3.2) set at 60% (group A, n = 40) or 30% (group B, n = 40) of the RR interval. Two blinded readers graded coronary artery image quality on a three-point scale. Radiation doses were calculated. Inter-observer agreement in grading image quality of the 1,154 coronary segments was good (kappa = 0.62). HRs were similar in groups A and B (85 +/- 13 bpm vs 85 +/- 14 bpm, p not significant). Significantly fewer coronary segments with non-diagnostic image quality occurred (i.e. score 3) in group B than in group A [2.8% (16/579) vs 8.3% (48/575), p < 0.001]. Seventeen patients (42.5%) of group A and 12 patients (30.0%) of group B had at least one non-diagnostic segment. Effective radiation doses were 2.3 +/- 0.3 mSv for chest CTA. A systolic acquisition window for high-pitch dual-source CTA in patients with high HRs (a parts per thousand yen70 bpm) significantly improves coronary artery image quality at a low radiation dose.
引用
下载
收藏
页码:2565 / 2571
页数:7
相关论文
共 50 条
  • [41] Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients
    Ghazal Adler
    Laurent Meille
    Adela Rohnean
    Anne Sigal-Cinqualbre
    André Capderou
    Jean-François Paul
    European Radiology, 2010, 20 : 1118 - 1123
  • [42] Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients
    Adler, Ghazal
    Meille, Laurent
    Rohnean, Adela
    Sigal-Cinqualbre, Anne
    Capderou, Andre
    Paul, Jean-Francois
    EUROPEAN RADIOLOGY, 2010, 20 (05) : 1118 - 1123
  • [43] High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose
    Rajiah, Prabhakar Shantha
    Dunning, Chelsea A. S.
    Rajendran, Kishore
    Tandon, Yasmeen K.
    Ahmed, Zaki
    Larson, Nicholas B.
    Collins, Jeremy D.
    Thorne, Jamison
    Williamson, Eric
    Fletcher, Joel G.
    McCollough, Cynthia
    Leng, Shuai
    INVESTIGATIVE RADIOLOGY, 2023, 58 (09) : 681 - 690
  • [44] High-Pitch CT Pulmonary Angiography in Third Generation Dual-Source CT: Image Quality in an Unselected Patient Population
    Sabel, Bastian O.
    Buric, Kristijan
    Karara, Nora
    Thierfelder, Kolja M.
    Dinkel, Julien
    Sommer, Wieland H.
    Meinel, Felix G.
    PLOS ONE, 2016, 11 (02):
  • [45] High-pitch Dual-source Computed Tomography Pulmonary Angiography in Freely Breathing Patients
    Bauer, Ralf W.
    Schell, Boris
    Beeres, Martin
    Wichmann, Julian L.
    Bodelle, Boris
    Vogl, Thomas J.
    Kerl, Josef Matthias
    JOURNAL OF THORACIC IMAGING, 2012, 27 (06) : 376 - 381
  • [46] High-Pitch 128-Slice Dual-Source CT for the Assessment of Coronary Stents in a Phantom Model
    Donati, Olivio F.
    Burg, Matthias C.
    Desbiolles, Lotus
    Karlo, Christoph
    Stolzmann, Paul
    Bunck, Alexander
    Baumueller, Stephan
    Marincek, Borut
    Seifarth, Harald
    Alkadhi, Hatem
    Leschka, Sebastian
    Maintz, David
    ACADEMIC RADIOLOGY, 2010, 17 (11) : 1366 - 1374
  • [47] Computed tomography pulmonary angiography using high-pitch dual-source scanner technology
    Al Hassan, Donya A.
    Waheed, Khawaja B.
    El Sirafy, Mohamed N.
    Khattab, Mohamad A.
    Al-Hammadi, Hassan I.
    Ibrahim, Motassem F.
    Ibrahim, Motassem F.
    Arulanantham, Zechariah J.
    SAUDI MEDICAL JOURNAL, 2019, 40 (03) : 230 - 237
  • [48] The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography
    Ying Liu
    Jian Xu
    Jian Li
    Jing Ren
    Hongtao Liu
    Junqing Xu
    Mengqi Wei
    Yuewen Hao
    Minwen Zheng
    Journal of Cardiothoracic Surgery, 8
  • [49] The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography
    Liu, Ying
    Xu, Jian
    Li, Jian
    Ren, Jing
    Liu, Hongtao
    Xu, Junqing
    Wei, Mengqi
    Hao, Yuewen
    Zheng, Minwen
    JOURNAL OF CARDIOTHORACIC SURGERY, 2013, 8
  • [50] Feasibility and Diagnostic Accuracy for Assessment of Coronary Artery Stenosis of Prospectively Electrocardiogram-gated High-pitch Spiral Acquisition Mode Dual-source CT Coronary Angiography in Patients with Relatively Higher Heart Rates: in Comparison wit
    Kai Sun
    Rui-juan Han
    Li-fang Cui
    Rui-ping Zhao
    Li-jun Ma
    Li-jun Wang
    Li-gang Li
    Chang-yong Li
    Chinese Medical Sciences Journal, 2012, 27 (04) : 213 - 219