High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose

被引:17
|
作者
Rajiah, Prabhakar Shantha [1 ]
Dunning, Chelsea A. S. [1 ]
Rajendran, Kishore [1 ]
Tandon, Yasmeen K. [1 ]
Ahmed, Zaki [1 ]
Larson, Nicholas B. [2 ]
Collins, Jeremy D. [1 ]
Thorne, Jamison [1 ]
Williamson, Eric [1 ]
Fletcher, Joel G. [1 ]
McCollough, Cynthia [1 ]
Leng, Shuai [1 ,3 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN USA
[2] Mayo Clin, Dept Quantitat Hlth Sci, Rochester, MN USA
[3] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
coronary CTA; atherosclerosis; iodine; virtual monoenergetic image; photon-counting detector CT; calcium blooming; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; AMERICAN-COLLEGE; PHANTOM; SYSTEM; MEDIA; RADIOLOGY; DISEASE;
D O I
10.1097/RLI.0000000000000961
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to evaluate the high-helical pitch, multienergy (ME) scanning mode of a clinical dual-source photon-counting detector (PCD) computed tomography (CT) and the benefit of virtual monoenergetic images (VMIs) for low-contrast-dose coronary CT angiography (CTA).Materials and MethodsHigh-pitch (3.2) ME coronary CTA was performed in PCD-CT in 27 patients using low contrast dose (30 mL of iohexol 350 mg/mL) and in 26 patients at routine contrast dose (60 mL). Low-energy-threshold 120 kV images (also known as T3D images) and 50 kiloelectron volts (50 keV) and 100 kiloelectron volts (100 keV) VMIs were reconstructed using a 1024 x 1024 matrix and 0.6-mm slices. The CT numbers, noise, and contrast-to-noise ratio (CNR) were measured in the ascending aorta (AA), left main coronary artery (LMCA), and distal left anterior descending (LAD) artery. Confidence in grading luminal stenosis with calcific plaque, noncalcific plaque, and stent was evaluated by 2 independent readers on a 0-100 scale (0 the lowest), and a CAD-RADS score was assigned. Image contrast enhancement, sharpness, noise, artifacts, and overall image quality were rated using a 5-point ordinal scale (1 the lowest).ResultsThe radiation doses (CTDI) in low- and routine-contrast cohorts were 2.5 & PLUSMN; 0.6 mGy and 3.1 & PLUSMN; 1.7 mGy, respectively (P = 0.12). At all measured locations, the mean CT number was >300 HU in 120 kV (LMCA 382.9 & PLUSMN; 76.2, distal LAD 341.0 & PLUSMN; 53.9, AA 399.5 & PLUSMN; 76.1) and 50 keV images (LMCA 667.5 & PLUSMN; 139.9, distal LAD 578.1 & PLUSMN; 121.5, AA 700.8 & PLUSMN; 142.5) in the low-contrast cohort, with a 96% increase in CT numbers for 50 keV over 120 kV. The CT numbers were significantly higher (P < 0.0001) in 50 keV than 120 kV and 100 keV VMI. The CNR was also significantly (P < 0.0001) higher in 50 keV than 120 kV and 100 keV images in all vessels. Confidence in the assessment of luminal stenosis in the presence of calcific plaque was significantly higher (P = 0.001) with the addition of 100 keV VMI (median score, 100) than using 50 keV alone (median score, 70) and 120 kV (median score, 70) for reader 1, but no significant differences were seen for reader 2 who had same median scores of 100 for all image types. The confidence in the assessment of luminal stenosis within a stent improved with the use of 100 keV images for both readers (reader 1: median scores for 50 + 100 keV = 100, 50 keV = 82.5, 120 kV = 82.5; reader 2: 50 + 100 keV = 100, 50 keV = 90, 120 kV = 90). There were no significant differences in confidence scores for assessment of luminal stenosis from noncalcific plaques for both readers. The reader-averaged qualitative scores for vascular enhancement and overall image quality were significantly higher for 50 keV VMI than for 120 kV images in both low- and routine-contrast dose cohorts. The image sharpness was nonsignificantly higher at 50 keV VMI than 120 kV images, and the artifact score was comparable for 50 keV VMI and 120 kV images. The noise was higher in 50 keV VMI than in 120 kV images.ConclusionsHigh-pitch ME PCD-CT mode produced diagnostic quality coronary CTA images at low radiation and iodinated contrast doses. The availability of ME VMIs significantly improved the CNR, overall image quality, and confidence in assessment of luminal stenosis in the presence of calcific plaques and stents, and resulted in change of CAD-RADS categories in 9 patients.
引用
收藏
页码:681 / 690
页数:10
相关论文
共 50 条
  • [1] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Lembcke, Alexander
    Schwenke, Carsten
    Hein, Patrick A.
    Knobloch, Gesine
    Durmus, Tahir
    Hamm, Bernd
    Huppertz, Alexander
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (01) : 120 - 127
  • [2] High-pitch dual-source CT coronary angiography with low volumes of contrast medium
    Alexander Lembcke
    Carsten Schwenke
    Patrick A. Hein
    Gesine Knobloch
    Tahir Durmus
    Bernd Hamm
    Alexander Huppertz
    [J]. European Radiology, 2014, 24 : 120 - 127
  • [3] Saving Contrast Media in Coronary CT Angiography with Photon-Counting Detector CT
    Cundari, Giulia
    Deilmann, Philipp
    Mergen, Victor
    Ciric, Kristina
    Eberhard, Matthias
    Jungblut, Lisa
    Alkadhi, Hatem
    Higashigaito, Kai
    [J]. ACADEMIC RADIOLOGY, 2024, 31 (01) : 212 - 220
  • [4] Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study
    Yang, Wen Jie
    Chen, Ke Min
    Liu, Bo
    Pang, Li Fang
    Zhang, Huan
    Pan, Zi Lai
    Yan, Fu Hua
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (01): : 245 - 252
  • [5] Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study
    Wen Jie Yang
    Ke Min Chen
    Bo Liu
    Li Fang Pang
    Huan Zhang
    Zi Lai Pan
    Fu Hua Yan
    [J]. The International Journal of Cardiovascular Imaging, 2013, 29 : 245 - 252
  • [6] Simultaneous high-pitch multi-energy CT pulmonary angiography using a dual-source photon-counting-detector CT: A phantom experiment
    Mihailovic, Jelena M.
    Bruesewitz, Michael R.
    Swicklik, Joseph R.
    Yalon, Mariana
    Rajiah, Prabhakar S.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024,
  • [7] Multienergy CT Using a Dual-Source Photon Counting Detector CT: Spectral and Dose Partition Optimization for Iodine Quantitation
    Tao, S.
    Ren, L.
    Rajendran, K.
    McCollough, C.
    Leng, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E407 - E408
  • [8] High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate
    Gordic, Sonja
    Husarik, Daniela B.
    Desbiolles, Lotus
    Leschka, Sebastian
    Frauenfelder, Thomas
    Alkadhi, Hatem
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (06): : 1173 - 1179
  • [9] Electrocardiographically triggered CT angiography of the whole aorta and coronary arteries with high-pitch dual-source CT
    张楠
    [J]. China Medical Abstracts (Internal Medicine), 2013, 30 (02) : 65 - 65
  • [10] Performance of calcium quantifications on low-dose photon-counting detector CT with high-pitch: A phantom study
    Zhou, Shanshui
    Liu, Peng
    Dong, Haipeng
    Li, Jiqiang
    Xu, Zhihan
    Schmidt, Bernhard
    Lin, Shushen
    Yang, Wenjie
    Yan, Fuhua
    Qin, Le
    [J]. HELIYON, 2024, 10 (12)