A signal-on electrochemiluminescence aptamer biosensor for the detection of ultratrace thrombin based on junction-probe

被引:75
|
作者
Zhang, Jing [1 ,2 ]
Chen, Pingping [1 ]
Wu, XiaoYan [1 ]
Chen, JingHua [1 ,3 ]
Xu, LiangJun [1 ]
Chen, GuoNan [1 ]
Fu, FengFu [1 ]
机构
[1] Fuzhou Univ, Dept Chem, Fujian Prov Key Lab Anal & Detect Technol Food Sa, Key Lab Anal & Detect Food Safety,Minist Educ, Fuzhou 350108, Fujian, Peoples R China
[2] Fujian Coll Med Occupat & Technol, Dept Pharmaceut, Fuzhou 350101, Fujian, Peoples R China
[3] Fujian Med Univ, Fac Pharm, Dept Pharmaceut Anal, Fuzhou 350004, Fujian, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 26卷 / 05期
关键词
Aptamer biosensor; ECL aptamer biosensor; Junction-probe; Thrombin; Electrochemiluminescence; SOLID-STATE ELECTROCHEMILUMINESCENCE; SEQUENCE-SPECIFIC DETECTION; ELECTROGENERATED CHEMILUMINESCENCE; MOLECULAR BEACON; DNA DETECTION; PROTEIN; FERROCENE; SELECTION; RU(BPY)(3)(2+); APTASENSORS;
D O I
10.1016/j.bios.2010.11.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel signal-on junction-probe electrogenerated chemiluminescence (ECL) aptamer biosensor has been developed for the detection of ultratrace thrombin based on a structure-switching ECL-quenching mechanism. The ECL aptamer biosensor comprises two main parts: an ECL substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Au nanoparticle and ruthenium (II) tris-bipyridine (Ru(bpy)(3)(2+)-AuNPs) on the surface of gold electrode (GE), and the ECL intensity switch contains three probes designed according to the "junction-probe" strategy. The first probe is capture probe (Cp) which was functionalized with a thiol group at one end and covalently attached to Ru(bpy)(3)(2+)-AuNPs modified GE through S-Au bonding. The second probe is aptamer probe (Ap), which containing 15-base anti-thrombin DNA aptamer. The third one is ferrocene-labeled probe (Fp), which was functionalized with ferrocene tag at one end. We demonstrated that, in the absence of thrombin, Cp, Ap and Fp will hybridize to form a ternary "Y" junction structure and resulted in a quenching of ECL of Ru(bpy)(3)(2+). Whereas, in the presence of thrombin, the Ap prefers to form the G-quadruplex aptamer-thrombin complex and lead to an obvious recovery of ECL of Ru(bpy)(3)(2+), which provided a sensing platform for the detection of thrombin. Using this reusable sensing platform, a simple, rapid and selective signal-on ECL aptamer biosensor for the detection of thrombin with a detection limit of 8.0 x 10(-15) M has been developed. The success in the present biosensor served as a significant step towards the development of monitoring ultratrace thrombin in clinical detection. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2645 / 2650
页数:6
相关论文
共 50 条
  • [21] Integration of an Aptamer-Based Signal-On Probe and a Paper-Based Origami Preconcentrator for Small Molecule Biomarkers Detection
    Na Eun Lee
    Ji Hye Hong
    Seungmin Lee
    Yong Kyoung Yoo
    Kang Hyeon Kim
    Jeong Soo Park
    Cheonjung Kim
    Junghyo Yoon
    Dae Sung Yoon
    Jeong Hoon Lee
    [J]. BioChip Journal, 2023, 17 : 439 - 446
  • [22] Integration of an Aptamer-Based Signal-On Probe and a Paper-Based Origami Preconcentrator for Small Molecule Biomarkers Detection
    Lee, Na Eun
    Hong, Ji Hye
    Lee, Seungmin
    Yoo, Yong Kyoung
    Kim, Kang Hyeon
    Park, Jeong Soo
    Kim, Cheonjung
    Yoon, Junghyo
    Yoon, Dae Sung
    Lee, Jeong Hoon
    [J]. BIOCHIP JOURNAL, 2023, 17 (04) : 439 - 446
  • [23] Integration of an Aptamer-Based Signal-On Probe and a Paper-Based Origami Preconcentrator for Small Molecule Biomarkers Detection
    Lee, Na Eun
    Hong, Ji Hye
    Lee, Seungmin
    Yoo, Yong Kyoung
    Kim, Kang Hyeon
    Park, Jeong Soo
    Kim, Cheonjung
    Yoon, Junghyo
    Yoon, Dae Sung
    Lee, Jeong Hoon
    [J]. BIOCHIP JOURNAL, 2023,
  • [24] Electrochemiluminescence biosensor for thrombin detection based on metal organic framework with electrochemiluminescence indicator embedded in the framework
    Huang, Qingqing
    Luo, Fang
    Lin, Cuiying
    Wang, Jian
    Qiu, Bin
    Lin, Zhenyu
    [J]. BIOSENSORS & BIOELECTRONICS, 2021, 189 (189):
  • [25] Electrochemical aptamer sensor for thrombin based on cerium complex signal probe
    Wang Cun
    Zou Xiao-Chuan
    Huang Yuan-Bo
    Hu Jing
    Deng Ming-Chuan
    Feng Xia
    [J]. CHINESE JOURNAL OF INORGANIC CHEMISTRY, 2023, 39 (10) : 1931 - 1940
  • [26] Detection of thrombin with a novel nano-biosensor based on aptamer fluorescence
    Tu Yong-Hua
    Cheng Gui-Fang
    Li, Lin
    Jing, Zheng
    Wu Zi-Rong
    He Ping-Gang
    Fang Yu-Zhi
    [J]. CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2006, 27 (12): : 2266 - 2270
  • [27] A signal-on fluorescence biosensor for detection of adenosine triphosphate based on click chemistry
    Sun, Ning
    Guo, Qi
    Shao, Jingwei
    Qiu, Bin
    Lin, Zhenyu
    Wong, K. Y.
    Chen, Guonan
    [J]. ANALYTICAL METHODS, 2014, 6 (10) : 3370 - 3374
  • [28] Label-free triple-helix aptamer as sensing platform for "signal-on" fluorescent detection of thrombin
    Xu, Nan
    Wang, Quanbo
    Lei, Jianping
    Liu, Lin
    Ju, Huangxian
    [J]. TALANTA, 2015, 132 : 387 - 391
  • [29] Novel sandwich-type electrochemiluminescence aptasensor based on luminol functionalized aptamer as signal probe for kanamycin detection
    Cheng, Shuting
    Xu, Rui
    Yang, Fengzhen
    Huang, Jingcheng
    Sun, Xia
    Huang, Xue
    Li, He
    Li, Falan
    Guo, Yemin
    Hasanzadeh, Mohammad
    Zhu, Yelong
    [J]. BIOELECTROCHEMISTRY, 2022, 147
  • [30] Electrochemiluminescence Biosensor Based on 3-D DNA Nanomachine Signal Probe Powered by Protein-Aptamer Binding Complex for Ultrasensitive Mucin 1 Detection
    Jiang, Xinya
    Wang, Haijun
    Wang, Huijun
    Zhuo, Ying
    Yuan, Ruo
    Chai, Yaqin
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (07) : 4280 - 4286