Integration of an Aptamer-Based Signal-On Probe and a Paper-Based Origami Preconcentrator for Small Molecule Biomarkers Detection

被引:0
|
作者
Lee, Na Eun [1 ,3 ]
Hong, Ji Hye [1 ,2 ]
Lee, Seungmin [1 ,2 ]
Yoo, Yong Kyoung [5 ]
Kim, Kang Hyeon [1 ]
Park, Jeong Soo [1 ]
Kim, Cheonjung [5 ]
Yoon, Junghyo [4 ]
Yoon, Dae Sung [2 ]
Lee, Jeong Hoon [1 ]
机构
[1] Kwangwoon Univ, Dept Elect Engn, Seoul 01897, South Korea
[2] Korea Univ, Sch Biomed Engn, Seoul 02841, South Korea
[3] Korea Univ, Coll Life Sci & Biotechnol, Dept Biotechnol, Seoul 02841, South Korea
[4] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[5] Catholic Kwandong Univ, Dept Elect Engn, 24,Beomil Ro 579 Beon GilGangwon Do, Gangwon Si 25601, South Korea
基金
新加坡国家研究基金会;
关键词
Lateral flow assay; Cortisol; Paper-based origami; Preconcentration; SALIVARY CORTISOL;
D O I
10.1007/s13206-023-00119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Point-of-care testing using paper-based lateral flow assays (LFAs) has emerged as an attractive diagnostic platform. However, detecting small molecules such as cortisol using LFAs is challenging due to limited binding sites and weak signal generation. Here, we report the development of cortisol-specific aptamer-based probes and a paper-based origami preconcentrator (POP) to amplify the probe signal. The cortisol-specific aptamers were conjugated onto gold nanoparticles and hybridized with signal probes to create the cortisol-specific signal-on probe. POP, consisting of patterned layers with convergent wicking zones, induces electrokinetic preconcentration of the released signaling probes. By integrating cortisol-selective aptamer-based probes and POP, we accurately diagnosed cortisol levels within 30 min of signal probe incubation, followed by 10 min of preconcentration. Our sensor was able to detect cortisol levels in the range of 25-1000 ng/mL, with typical cortisol levels in plasma ranging from 40 to 250 ng/mL falling within this range. The successful detection of the wide range of cortisol samples using this approach highlights the potential of this platform as a point-of-care testing tool, particularly for lateral flow assay-based detection of small molecules like cortisol. Our approach offers a convenient and reliable method of cortisol level testing with a portable and accessible diagnosis device.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Integration of an Aptamer-Based Signal-On Probe and a Paper-Based Origami Preconcentrator for Small Molecule Biomarkers Detection
    Na Eun Lee
    Ji Hye Hong
    Seungmin Lee
    Yong Kyoung Yoo
    Kang Hyeon Kim
    Jeong Soo Park
    Cheonjung Kim
    Junghyo Yoon
    Dae Sung Yoon
    Jeong Hoon Lee
    BioChip Journal, 2023, 17 : 439 - 446
  • [2] Integration of an Aptamer-Based Signal-On Probe and a Paper-Based Origami Preconcentrator for Small Molecule Biomarkers Detection
    Lee, Na Eun
    Hong, Ji Hye
    Lee, Seungmin
    Yoo, Yong Kyoung
    Kim, Kang Hyeon
    Park, Jeong Soo
    Kim, Cheonjung
    Yoon, Junghyo
    Yoon, Dae Sung
    Lee, Jeong Hoon
    BIOCHIP JOURNAL, 2023, 17 (04) : 439 - 446
  • [3] Aptamer-Based Origami Paper Analytical Device for Electrochemical Detection of Adenosine
    Liu, Hong
    Xiang, Yu
    Lu, Yi
    Crooks, Richard M.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (28) : 6925 - 6928
  • [4] An aptamer-based signal-on and multiplexed sensing platform for one-spot simultaneous electronic detection of proteins and small molecules
    Xiang, Yun
    Qian, Xiaoqing
    Jiang, Bingying
    Chai, Yaqin
    Yuan, Ruo
    CHEMICAL COMMUNICATIONS, 2011, 47 (16) : 4733 - 4735
  • [5] Aptamer-based fluorometric determination of norovirus using a paper-based microfluidic device
    Xuan Weng
    Suresh Neethirajan
    Microchimica Acta, 2017, 184 : 4545 - 4552
  • [6] A signal-on electrochemiluminescence aptamer biosensor for the detection of ultratrace thrombin based on junction-probe
    Zhang, Jing
    Chen, Pingping
    Wu, XiaoYan
    Chen, JingHua
    Xu, LiangJun
    Chen, GuoNan
    Fu, FengFu
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (05): : 2645 - 2650
  • [7] Aptamer-based fluorometric determination of norovirus using a paper-based microfluidic device
    Weng, Xuan
    Neethirajan, Suresh
    MICROCHIMICA ACTA, 2017, 184 (11) : 4545 - 4552
  • [8] Innovative engineering and sensing strategies for aptamer-based small-molecule detection
    Alkhamis, Obtin
    Canoura, Juan
    Yu, Haixiang
    Liu, Yingzhu
    Xiao, Yi
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 121
  • [9] Aptamer-based environmental biosensors for small molecule contaminants
    Van-Thuan Nguyen
    Kwon, Young Seop
    Gu, Man Bock
    CURRENT OPINION IN BIOTECHNOLOGY, 2017, 45 : 15 - 23
  • [10] Aptamer-Based Biosensors For Biomarkers Detection (Part I)
    Mikula, Edyta
    Kaczmarek, Halina
    CURRENT MEDICINAL CHEMISTRY, 2022, 29 (37) : 5793 - 5794