A signal-on electrochemiluminescence aptamer biosensor for the detection of ultratrace thrombin based on junction-probe

被引:75
|
作者
Zhang, Jing [1 ,2 ]
Chen, Pingping [1 ]
Wu, XiaoYan [1 ]
Chen, JingHua [1 ,3 ]
Xu, LiangJun [1 ]
Chen, GuoNan [1 ]
Fu, FengFu [1 ]
机构
[1] Fuzhou Univ, Dept Chem, Fujian Prov Key Lab Anal & Detect Technol Food Sa, Key Lab Anal & Detect Food Safety,Minist Educ, Fuzhou 350108, Fujian, Peoples R China
[2] Fujian Coll Med Occupat & Technol, Dept Pharmaceut, Fuzhou 350101, Fujian, Peoples R China
[3] Fujian Med Univ, Fac Pharm, Dept Pharmaceut Anal, Fuzhou 350004, Fujian, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 26卷 / 05期
关键词
Aptamer biosensor; ECL aptamer biosensor; Junction-probe; Thrombin; Electrochemiluminescence; SOLID-STATE ELECTROCHEMILUMINESCENCE; SEQUENCE-SPECIFIC DETECTION; ELECTROGENERATED CHEMILUMINESCENCE; MOLECULAR BEACON; DNA DETECTION; PROTEIN; FERROCENE; SELECTION; RU(BPY)(3)(2+); APTASENSORS;
D O I
10.1016/j.bios.2010.11.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel signal-on junction-probe electrogenerated chemiluminescence (ECL) aptamer biosensor has been developed for the detection of ultratrace thrombin based on a structure-switching ECL-quenching mechanism. The ECL aptamer biosensor comprises two main parts: an ECL substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Au nanoparticle and ruthenium (II) tris-bipyridine (Ru(bpy)(3)(2+)-AuNPs) on the surface of gold electrode (GE), and the ECL intensity switch contains three probes designed according to the "junction-probe" strategy. The first probe is capture probe (Cp) which was functionalized with a thiol group at one end and covalently attached to Ru(bpy)(3)(2+)-AuNPs modified GE through S-Au bonding. The second probe is aptamer probe (Ap), which containing 15-base anti-thrombin DNA aptamer. The third one is ferrocene-labeled probe (Fp), which was functionalized with ferrocene tag at one end. We demonstrated that, in the absence of thrombin, Cp, Ap and Fp will hybridize to form a ternary "Y" junction structure and resulted in a quenching of ECL of Ru(bpy)(3)(2+). Whereas, in the presence of thrombin, the Ap prefers to form the G-quadruplex aptamer-thrombin complex and lead to an obvious recovery of ECL of Ru(bpy)(3)(2+), which provided a sensing platform for the detection of thrombin. Using this reusable sensing platform, a simple, rapid and selective signal-on ECL aptamer biosensor for the detection of thrombin with a detection limit of 8.0 x 10(-15) M has been developed. The success in the present biosensor served as a significant step towards the development of monitoring ultratrace thrombin in clinical detection. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2645 / 2650
页数:6
相关论文
共 50 条
  • [31] An Electrochemiluminescence Biosensor for Determination of Pb2+ Based on G-Quadruplex of Aptamer Probe
    Wei Xiao-Ping
    Yang Feng
    Ding Fan
    Li Jian-Ping
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (07) : 942 - 947
  • [32] Signal-on low background electrochemiluminescence biosensor based on the target-triggered dual signal amplifications and difference of electrostatic attraction
    Li, Xianghui
    Lu, Yilei
    Chen, Yiming
    Pan, Zhipeng
    Lin, Ni
    Lin, Zhenyu
    Chen, Huixing
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2023, 377
  • [33] A signal-on fluorescent biosensor for mercury detection based on a cleavable phosphorothioate RNA fluorescent probe and metal-organic frameworks
    Mei, Yang
    Yang, Si
    Li, Chenxi
    Chen, Wenliang
    Liu, Rong
    Xu, Kexin
    [J]. ANALYTICAL METHODS, 2022, 14 (43) : 4418 - 4425
  • [34] Signal-on electrochemiluminescence biosensor for microRNA-319a detection based on two-stage isothermal strand-displacement polymerase reaction
    Wang, Minghui
    Zhou, Yunlei
    Yin, Huanshun
    Jiang, Wenjing
    Wang, Haiyan
    Ai, Shiyun
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 107 : 34 - 39
  • [35] Signal-On Fluorescence Biosensor for Detection of miRNA-21 Based on ROX labeled Specific Stem-Loop Probe
    Heidarian, Somayeh
    Osgoei, Laya Takbiri
    Karizi, Shohreh Zare
    Amani, Jafar
    Arabian, Sedigheh
    [J]. IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2024, 23 (01):
  • [36] Highly sensitive aptamer based on electrochemiluminescence biosensor for label-free detection of bisphenol A
    Shengjie Ye
    Ruihong Ye
    Yuande Shi
    Bin Qiu
    Longhua Guo
    Dihui Huang
    Zhenyu Lin
    Guonan Chen
    [J]. Analytical and Bioanalytical Chemistry, 2017, 409 : 7145 - 7151
  • [37] Highly sensitive aptamer based on electrochemiluminescence biosensor for label-free detection of bisphenol A
    Ye, Shengjie
    Ye, Ruihong
    Shi, Yuande
    Qiu, Bin
    Guo, Longhua
    Huang, Dihui
    Lin, Zhenyu
    Chen, Guonan
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (30) : 7145 - 7151
  • [38] Electrochemical biosensor based on RNA aptamer and ferrocenecarboxylic acid signal probe for C-reactive protein detection
    Wang, Zifeng
    Liu, Shuyuan
    Shi, Zhuo
    Lu, Dingxi
    Li, Zhanhong
    Zhu, Zhigang
    [J]. TALANTA, 2024, 277
  • [39] DNA cycle amplification device on magnetic microbeads for determination of thrombin based on graphene oxide enhancing signal-on electrochemiluminescence
    Guo, Yingshu
    Jia, Xueping
    Zhang, Shusheng
    [J]. CHEMICAL COMMUNICATIONS, 2011, 47 (02) : 725 - 727
  • [40] A Sensitive Signal-on Supersandwich DNA Biosensor Based on the Enhancement of Poly(aniline-luminol) Nanowires Electrochemiluminescence by Ferrocene
    Zhifang Ding
    Yue Li
    Ying Bao
    Kexin Han
    Iparguli Turepu
    Guixin Li
    [J]. Analytical Sciences, 2021, 37 : 1525 - 1531