An improved HarshawTLD™ extremity dosimeter - DXTRAD beta ring

被引:1
|
作者
Luo, Ling Z. [1 ]
Velbeck, Ken [1 ]
Rotunda, Joseph [1 ]
Esser, Reiner [2 ]
机构
[1] Thermo Fisher Sci, Oakwood Village, OH 44146 USA
[2] Thermo Fisher Sci, D-42857 Remscheid, Germany
关键词
Extremity; PTB type test; DXTRAD; Beta monitoring; HarshawTLD; PERFORMANCE; RADIATION; SYSTEM;
D O I
10.1016/j.radmeas.2011.04.036
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An improved HarshawTLD (TM) extremity dosimeter system that is rugged in design and easy to wear is presented. This dosimeter is improved from the earlier version (2008) for personnel beta monitoring while still having full range photon performance. The dosimeter style, referred to as DXTRAD, is small in size and has identification by means of a circular barcode. It consists of a detector composed of a thin 7 mg cm(-2) monolayer of HarshawTLD-700H ((7)LiF:Mg,Cu,P) powder and a ring cap with a 3.3 mg cm(-2) entrance window. The use of the TLD-700H TLD material provides a good beta energy response as well as a flat energy response from low energy x-rays to high energy gamma rays. A new assembly tool that improves the consistency of dosimeter geometry and ruggedness for warm and cold sterilization is also developed. With the optimized design, this dosimeter is capable of meeting the stringent energy and angular response requirements of the Physikalisch Technische Bundesanstalt (PTB) for both betas and photons. Presented in this paper are the ISO-12974 and PTB type tests as well as additional operational tests, such as residue, reuse, warm and cold sterilization, and environmental leakage. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:621 / 625
页数:5
相关论文
共 50 条
  • [1] AN IMPROVED FINGERTIP DOSIMETER FOR BETA RADIATION
    COUCH, NW
    WATSON, JE
    HAMRICK, PE
    HEALTH PHYSICS, 1987, 52 : S35 - S35
  • [2] IMPROVED BETA, PHOTON, AND NEUTRON DOSIMETER
    JONES, DE
    GESELL, TF
    CUSIMANO, JP
    GUPTA, VP
    KALBEITZER, FL
    PARKER, D
    HEALTH PHYSICS, 1979, 37 (06): : 843 - 843
  • [3] MEASUREMENT OF EXTREMITY DOSES OF NUCLEAR ENERGY WORKER BY USING RING DOSIMETER
    Islam, M. Tahidul
    Ferdous, J.
    Haque, M. M.
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (03) : 271 - 275
  • [4] THE ENERGY AND ANGLE DEPENDENCE OF RESPONSE OF THE VINTEN EXTREMITY DOSIMETER TO BETA RADIATION
    DUTT, JC
    MINGJUN, C
    BARTLETT, DT
    RADIATION PROTECTION DOSIMETRY, 1988, 25 (02) : 127 - 131
  • [5] DEVELOPMENT OF AN IMPROVED FINGERTIP DOSIMETER FOR BETA-RADIATION
    CROUCH, NW
    HAMRICK, PE
    WATSON, JE
    ENVIRONMENTAL HEALTH PERSPECTIVES, 1987, 75 : 144 - 145
  • [6] EXTREMITY DOSIMETER MONITORING SERVICE
    CURRY, RG
    GREENSLADE, E
    RADIATION PROTECTION DOSIMETRY, 1986, 17 (1-4) : 115 - 117
  • [7] A NEW TYPE OF EXTREMITY DOSIMETER
    UCHRIN, G
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (01): : 173 - 175
  • [8] AN EXTREMITY DOSIMETER SYSTEM BASED ON TLD
    JULIUS, HW
    BUSUOLI, G
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (01): : 153 - 155
  • [9] Wrist dosimeter in nuclear medicine - An alternative for the ring dosimeter?
    Malgorzata, Wrzesien
    Jerzy, Olszewski
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 54 : 117 - 120
  • [10] THE RE-USABILITY OF THE VINTEN EXTREMITY DOSIMETER
    OHAGAN, JB
    FRANCIS, TM
    WILLIAMS, SM
    RADIATION PROTECTION DOSIMETRY, 1987, 20 (03) : 191 - 192