An improved HarshawTLD™ extremity dosimeter - DXTRAD beta ring

被引:1
|
作者
Luo, Ling Z. [1 ]
Velbeck, Ken [1 ]
Rotunda, Joseph [1 ]
Esser, Reiner [2 ]
机构
[1] Thermo Fisher Sci, Oakwood Village, OH 44146 USA
[2] Thermo Fisher Sci, D-42857 Remscheid, Germany
关键词
Extremity; PTB type test; DXTRAD; Beta monitoring; HarshawTLD; PERFORMANCE; RADIATION; SYSTEM;
D O I
10.1016/j.radmeas.2011.04.036
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An improved HarshawTLD (TM) extremity dosimeter system that is rugged in design and easy to wear is presented. This dosimeter is improved from the earlier version (2008) for personnel beta monitoring while still having full range photon performance. The dosimeter style, referred to as DXTRAD, is small in size and has identification by means of a circular barcode. It consists of a detector composed of a thin 7 mg cm(-2) monolayer of HarshawTLD-700H ((7)LiF:Mg,Cu,P) powder and a ring cap with a 3.3 mg cm(-2) entrance window. The use of the TLD-700H TLD material provides a good beta energy response as well as a flat energy response from low energy x-rays to high energy gamma rays. A new assembly tool that improves the consistency of dosimeter geometry and ruggedness for warm and cold sterilization is also developed. With the optimized design, this dosimeter is capable of meeting the stringent energy and angular response requirements of the Physikalisch Technische Bundesanstalt (PTB) for both betas and photons. Presented in this paper are the ISO-12974 and PTB type tests as well as additional operational tests, such as residue, reuse, warm and cold sterilization, and environmental leakage. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:621 / 625
页数:5
相关论文
共 50 条
  • [31] Design of an improved neutron dose equivalent dosimeter
    Brushwood, JM
    Beeley, PA
    Spyrou, NM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 304 - 308
  • [32] IMPROVED BETA-RAY DETECTOR WITH A RING-TYPE CONICAL PHOSPHOR
    MISHRA, RK
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1979, 17 (06) : 399 - 400
  • [33] A NEW SOLID-STATE BETA-DOSIMETER
    JONES, AR
    SANDERS, JM
    RADIATION PROTECTION DOSIMETRY, 1986, 17 (1-4) : 105 - 109
  • [34] PERFORMANCE OF AN EXOELECTRON DOSIMETER BADGE FOR PERSONNEL BETA DOSIMETRY
    MERWIN, SE
    SWINTH, KL
    RADIATION PROTECTION DOSIMETRY, 1989, 28 (03) : 219 - 222
  • [35] Use of Commercially Available Optically Stimulated Luminescence Dosimeter As Extremity Dose Estimator
    Georgeson, David L.
    Christiansen, Byron H.
    HEALTH PHYSICS, 2021, 120 (01): : 86 - 93
  • [36] Investigation of phosphate glass doped lanthanum as beta dosimeter
    El-Kheshen, Amany
    Woda, Clemens
    Discher, Michael
    El-Faramawy, Nabil
    JOURNAL OF LUMINESCENCE, 2018, 200 : 254 - 259
  • [37] VERGLEICH VON EICHVERFAHREN FUR BETA-DOSIMETER
    HERRMANN, D
    NUKLEONIK, 1966, 8 (06): : 320 - &
  • [38] Investigation of phosphate glass activated with terbium oxide as beta dosimeter
    Abdou, Naglaa Y.
    El-Faramawy, Nabil
    El Kinawy, Mohamed
    Abd-Allah, Wesam M.
    MATERIALS LETTERS, 2022, 327
  • [39] Response of ionization chamber based pocket dosimeter to beta radiation
    Kumar, Munish
    Gupta, Anil
    Pradhan, S. M.
    Bakshi, A. K.
    Chougaonkar, M. P.
    Babu, D. A. R.
    APPLIED RADIATION AND ISOTOPES, 2013, 82 : 130 - 132
  • [40] A MATRIX METHOD FOR EVALUATION OF BETA-GAMMA DOSIMETER FILM
    KIRCHNER, RA
    RYAN, TL
    HEALTH PHYSICS, 1967, 13 (07): : 810 - +