An improved HarshawTLD™ extremity dosimeter - DXTRAD beta ring

被引:1
|
作者
Luo, Ling Z. [1 ]
Velbeck, Ken [1 ]
Rotunda, Joseph [1 ]
Esser, Reiner [2 ]
机构
[1] Thermo Fisher Sci, Oakwood Village, OH 44146 USA
[2] Thermo Fisher Sci, D-42857 Remscheid, Germany
关键词
Extremity; PTB type test; DXTRAD; Beta monitoring; HarshawTLD; PERFORMANCE; RADIATION; SYSTEM;
D O I
10.1016/j.radmeas.2011.04.036
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An improved HarshawTLD (TM) extremity dosimeter system that is rugged in design and easy to wear is presented. This dosimeter is improved from the earlier version (2008) for personnel beta monitoring while still having full range photon performance. The dosimeter style, referred to as DXTRAD, is small in size and has identification by means of a circular barcode. It consists of a detector composed of a thin 7 mg cm(-2) monolayer of HarshawTLD-700H ((7)LiF:Mg,Cu,P) powder and a ring cap with a 3.3 mg cm(-2) entrance window. The use of the TLD-700H TLD material provides a good beta energy response as well as a flat energy response from low energy x-rays to high energy gamma rays. A new assembly tool that improves the consistency of dosimeter geometry and ruggedness for warm and cold sterilization is also developed. With the optimized design, this dosimeter is capable of meeting the stringent energy and angular response requirements of the Physikalisch Technische Bundesanstalt (PTB) for both betas and photons. Presented in this paper are the ISO-12974 and PTB type tests as well as additional operational tests, such as residue, reuse, warm and cold sterilization, and environmental leakage. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:621 / 625
页数:5
相关论文
共 50 条
  • [21] CHARACTERISTICS OF A NEW TYPE OF VINTEN DOSIMETER FOR SKIN EXTREMITY MONITORING
    DUTT, JC
    ILES, WJ
    BARTLETT, DT
    RADIATION PROTECTION DOSIMETRY, 1990, 33 (1-4) : 303 - 306
  • [22] AN IMPROVED CLINICAL DOSIMETER FOR THE MEASUREMENT OF RADIATION
    FEDORUK, SO
    JOHNS, HE
    WATSON, TA
    RADIOLOGY, 1954, 62 (02) : 177 - 182
  • [23] EVALUATING THE PERFORMANCE OF THE HARSHAW™ DXTRAD LiF:Mg,Cu,P FINGER RING WITH TWO DIFFERENT THICKNESS FILTERS
    Baker, S. T.
    Roberts, G. H.
    Gilvin, P. J.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 243 - 245
  • [24] A PASSIVE MUTLI-ELEMENT BETA DOSIMETER
    SCHERPELZ, RI
    ENDRES, GWR
    RATHBUN, LA
    MURPHY, DW
    HEALTH PHYSICS, 1983, 45 (01): : 206 - 206
  • [25] Testing results of a new extremity dosimeter designed to meet PTB requirements
    Velbeck, K. J.
    Luo, L. Z.
    Rotunda, J. E.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 651 - 654
  • [26] Theoretical calculation of gamma dose conversion factors for personnel extremity dosimeter
    Yoon, SC
    Kim, JS
    Kim, KP
    Lee, WK
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D257 - D259
  • [27] RaDoM2: an improved radon dosimeter
    Romano, S.
    Caresana, M.
    Curioni, A.
    Silari, M.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (10)
  • [28] AN IMPROVED VOLUMETRIC DOSIMETER FOR INTERNAL DOSE VERIFICATION
    AISSI, A
    POSTON, JW
    HEALTH PHYSICS, 1984, 46 (02): : 371 - 376
  • [29] A GLASS DOSIMETER WASHING TECHNIQUE FOR IMPROVED REPRODUCIBILITY
    MENKES, CK
    HEALTH PHYSICS, 1966, 12 (03): : 429 - +
  • [30] EXPOSURE TO RADIATION DURING SURGERY, MEASURED WITH A RING DOSIMETER
    WICKI, O
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1975, 339 : 677 - 677